Reports until 16:28, Wednesday 09 October 2024
H1 CDS
david.barker@LIGO.ORG - posted 16:28, Wednesday 09 October 2024 - last comment - 16:39, Wednesday 09 October 2024(80574)
Corner station Dolphin crash, h1sush7 error caused crash of h1sush34, h1lsc0 and h1omc0

At 15:34:40 Wed 09oct2024 PDT a corner station dolphin glitch caused DACKILLs for h1sush34, h1lsc0 and h1omc0.

Images attached to this report
Comments related to this report
ezekiel.dohmen@LIGO.ORG - 16:39, Wednesday 09 October 2024 (80576)
h1sush7 has other Dolphin logs associated with previous glitches. 

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=75921
[Wed Feb 21 11:33:40 2024] IXH Adapter 0 : Port 0 is not operational -- UpTime: 0 sec - Event = 0

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=79561
[Thu Aug 15 16:37:15 2024] IXH Adapter 0 : Port 0 is not operational -- UpTime: 0 sec - Event = 0

And today:
[Wed Oct  9 15:34:25 2024] IXH Adapter 0 : Port 0 is not operational -- UpTime: 0 sec - Event = 0
[Wed Oct  9 15:34:25 2024] dis-ix-ntb: dis-ix-ntb0: Detected IXS600 (601) switch, SUB2, port 1, global port 12
[Wed Oct  9 15:34:25 2024] IXH Adapter 0 : Local adapter is connected to IXS600 switch, SUB2, port 1
[Wed Oct  9 15:34:25 2024] IXH Adapter 0 : Link 0 is operational - Link width: x8 - PCIe Gen 2 -- Downtime: 0 sec

We might want to check cable when we get a chance, and if that dose not resolve the issue consider replacing the card. 
Non-image files attached to this comment