sheila.dwyer@LIGO.ORG - posted 14:37, Friday 03 January 2025 (82097)
Squeezer data set and comparison to quantum noise model

This is an update on the quantum noise compairson to models started in 80747.  Apoloiges for the large numer of plots.  The main message is that we have a decent model of the quantum noise from October (see this and this plot ) can get a fairly independent constraint on homodyne angle and SRC detunings from these squeezer data sets without the filter cavity, and some loose estimates for arm power based on squeezer losses.  There is a discrepancy between the model and the data in the traces taken near anti-squeezing without the filter cavity that is interesting, and I haven't tried to model mode mismatches yet.

Outline of how this model is made:

The first two attachments show data from mid October (80664), separated into two different plots (one with mid squeezing, one with +/-10 degrees from sqz and a sqz) to make it easier to read.  We can look at the mid and low frequencies to help us constrain the model for homodyne angle, SRC detuning, and maybe mode matching and FC parameters.  With the filter cavity, the traces that are +/- 10 degrees from squeezing and anti-squeezing don't provide much information, we can probably skip these in future data sets, but the ones +/-10 degrees from anti-squeezing without the filter cavity are interesting.

Arm power: We can get some constraints on arm power by assuming that all of our unknown loss is injection loss, or all readout loss, this gives us a range of 327kW-381kW with a homodyne angle of 10.8 degrees and no SRC detuning.  Attached are plots made for the high and lower power models, by clicking back and forth you can see that the lowest powers seem to disagree with the low frequency data, implying that some of our unknown losses truly are readout losses, but this isn't a very precise way to estimate arm power.

SRC detuning: Without the filter cavity, the mid squeezing traces are most clearly sensitive to SRC detuning, shown in this attachment where the SRC detuning of 0.057 degrees is clearly too large. You can flip through these 5 SRC plots which suggests that our SRC detuning at the time of these measurements was between 0 and -0.057 degrees (I'll leave it at -0.029 degrees, or -1mrad in the model) . 

Homodyne angle: In 80747 we noticed that anti-squeezing without the filter cavity is very sensitive to the homodyne angle, and that we've been using the wrong sign for our modeling in O4.  Here are plots that reaffirm that the negative homodyne angle is wrong, with mid squeezing (as we did in 80747) and with squeezing angle +/-10degrees from squeezing and anti-squeezing, which also clearly shows the problem for those traces near anti-squeezing.  It's also nice to notice that the mid sqz traces aren't especially sensitive to homodyne angle in the mid frequency range taht we were using to set the SRC detuning, so this data set without the filter cavity can give us fairly independent constraints on SRC detuning and homodyne angle.  Here is a plot of the homodyne angle of 10.7 degrees (based on 71913), without the squeezing traces so that it's easier to see what's happening.  There is a large discrepancy between the model and FDAS -10 degrees, from 30-55Hz, and there is also a smaller discrepancy for FDAS+10 degrees in this frequency range. This discrepancy can be redcued a bit by making the homodyne angle larger, but that doesn't seem to be a good model of the data, so this discrepancy is probably due to something we aren't modeling correctly here.

Filter cavity detuning:  We have used -33Hz as the filter cavity detuning, but data from mid squeezing with the filter cavity suggests that the detuning in this data set closer to 27 Hz. Here is a series of plots to show how mid sqz is sensitive to FC detuning.

The last two plots are with the final model paramters, it is a reasonably good description of the data, with the main discrepancy remaining in the anti-squeezing without the filter cavity.  The scripts, parameters and data used to make these plots is in quantumnoisebudgeting commit 92f7e965.  The quantum noise paramters used are here.