Reports until 15:33, Thursday 07 November 2013
H1 SEI
hugh.radkins@LIGO.ORG - posted 15:33, Thursday 07 November 2013 - last comment - 07:56, Friday 08 November 2013(8430)
WBSC3 ITMx HEPI Moves for IAS & now locked for ACB

As Jason logged yesterday, the ITMx was good except for the Yaw.  SEI turned the HEPI DSCW Springs to correct the Yaw error; we brough it from 1.6mrad to 35urads.  We then checked and leveled the Optical Table.  It was only barely out of spec with 0.3mm over the table; we got it to <0.2mm just hitting our 100urad goal.  With the Optical Level using TGT402 for reference, the OT is 0.6mm high.  I locked the HEPI after final DI readings for ACB work.

With these Yaw and Level adjustments, some unintended motion occur but they are small.  Based on the Dial Indicators, the platform moved 0.1mm South, 0.2mm East, & 20urads CW since the observations IAS took. We should be in OK shape.

Attached find my log book pages for this saga.  Thanks, to GregG & MitchellR

Non-image files attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 07:56, Friday 08 November 2013 (8435)

Thanks too of course to Jason & Doug for IAS.