edgard.bonilla@LIGO.ORG - posted 20:34, Friday 18 July 2025 (85857)
Changes to the HLTS_W_EST model to test the OSEM estimator on H1 SR3

Edgard, Ivey, Brian.

Relevant FRS ticket : 32526

We made modifications to the HLTS_W_EST and estimator library parts to add DQ channels to monitor the total drive request to the M1 OSEMs with and without the estimator damping. In passing, we made a few changes to the names of channels on the EST block (by modifying ESTIMATOR_PARTS.mdl ) to make them a bit more readable/less redundant. These changes will only affect the H1 SR3/PR3 models only.

The changes were committed to the userapps svn under revision 32426.

 

Oli mentioned that they will do a model restart to get these changes in on Tuesday, as long as we got the changes in before Monday.

The estimator MEDM screens haven't been updated yet, but I think Brian will get to it on Monday.

____________

This is a summary of the library part changes [see attached.pdf for screenshots of these changes in the library parts]:

SIXOSEM_T_STAGE_MASTER_W_EST.mdl

HLTS_MASTER_W_EST.mdl

ESTIMATOR_PARTS.mdl

 

 

Non-image files attached to this report