Reports until 17:01, Monday 21 July 2025
H1 SUS
oli.patane@LIGO.ORG - posted 17:01, Monday 21 July 2025 (85900)
Compensation filters for MC2, PR2, TMSX, and ETMX M0/R0/L1 updated to satamp channel specific filters

After last week's satamp changes (85770), the compensation filters found in the OSEMINF filter bank for MC2, PR2, TMSX, and ETMX M0/R0/L1 were all updated to a generic compensation filter of 5.31:0.0969. I have now updated those filters based on the experimental measurements Jeff got for each satamp's channel (the same as what I did in 85746).

To update the compensation filters, I used the newest version of my script satampswap_bestpossible_filterupdate_ECR_E2400330.py, svn revision r12475. This newest version of the code allows you to specify which stage you want to update, if you aren't wanting to update every stage listed in the txt files. Here is a txt file of my inputs and the corresponding outputs for the lines of code that I ran.

I have loaded these more accurate filters in for these suspension/stages.

Images attached to this report
Non-image files attached to this report