Reports until 17:59, Wednesday 23 July 2025
H1 SUS
oli.patane@LIGO.ORG - posted 17:59, Wednesday 23 July 2025 (85952)
Satamp swap OSEM noise part 3.5 (TMSX, ETMX M0/R0/L1)

These are the remainder of the noise comparison plots for before and after the sat amp swaps for TMSX and ETMX M0/R0/L1. These swaps were done for TMSX, ETMX M0/R0/L1, MC2, and PR2 on July 15 (85770). I posted noise comparison plots for MC2 and PR2 (85786), but we didn't yet have a good 'after' time where End X wasn't in maintenance, going through an earthquake, or moving stuff around for relocking. Now we have had a good time stretch, so here are the results:

Note: For ETMX L1, there are no DAMP channels, so instead I looked at the WIT_{L,P,Y} channels. Not sure how accurate these are. The edits to make this possible in the script /ligo/svncommon/SusSVN/sus/trunk/Common/MatlabTools/damp_regression_compare.m  have been svn'd as r12483

TMSX
Results

/ligo/svncommon/SusSVN/sus/trunk/TMTS/H1/TMSX/SAGM1/Results/allDampRegressCompare_H1SUSTMSX_M1_NoiseComparison_1435150628vs1437199319-1200.pdf
r12479
Data
/ligo/svncommon/SusSVN/sus/trunk/TMTS/H1/TMSX/SAGM1/Data/dampRegress_H1SUSTMSX_M1_1435150628_1200.mat
/ligo/svncommon/SusSVN/sus/trunk/TMTS/H1/TMSX/SAGM1/Data/dampRegress_H1SUSTMSX_M1_1437199319_1200.mat
r12479

ETMX
M0
Results

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGM0/Results/allDampRegressCompare_H1SUSETMX_M0_NoiseComparison_1435060998vs1436769334-1200.pdf
r12480
Data
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGM0/Data/dampRegress_H1SUSETMX_M0_1435060998_1200.mat
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGM0/Data/dampRegress_H1SUSETMX_M0_1436769334_1200.mat
r12480

R0
Results

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGR0/Results/allDampRegressCompare_H1SUSETMX_R0_NoiseComparison_1435060998vs1436769334-1200.pdf
r12841
Data
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGR0/Data/dampRegress_H1SUSETMX_R0_1435060998_1200.mat
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGR0/Data/dampRegress_H1SUSETMX_R0_1436769334_1200.mat
r12481

L1
Results
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGL1/Results/allDampRegressCompare_H1SUSETMX_L1_NoiseComparison_1435060998vs1436769334-1200.pdf
r12482
Data
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGL1/Data/dampRegress_H1SUSETMX_L1_1435060998_1200.mat
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGL1/Data/dampRegress_H1SUSETMX_L1_1436769334_1200.mat
r12482

Non-image files attached to this report