Over the past couple of weeks, I took transfer functions for SR3 and PR3 with different configurations of P or Y damping gain for the estimator, so here are the results for those plus a comparison of their peak locations.
SR3
DAMP P gain at -0.1 (nominally -0.5), other dof gains at their nominal -0.5
Measurements: 86203
Results: /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/SAGM1/Results/2025-08-05_1800_H1SUSSR3_M1_ALL_TFs.pdf r12611
DAMP Y gain at -0.1 (nominally -0.5), other dof gains at their nominal -0.5
Measurements: 86202
Results: /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/SAGM1/Results/2025-08-05_1700_H1SUSSR3_M1_ALL_TFs.pdf r12612
PR3
DAMP P gain at -0.2 (nominally -1.0), other dof gains at their nominal -0.2
Measurements: 86459
Results: /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/SAGM1/Results/2025-08-19_1815_H1SUSPR3_M1_ALL_TFs.pdf r12613
DAMP Y gain at -0.2 (nominally -1.0), other dof gains at their nominal -0.2
Measurements: 86459
Results: /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/SAGM1/Results/2025-08-19_1715_H1SUSPR3_M1_ALL_TFs.pdf r12614
Comparison between SR3 and PR3
Results:
/ligo/svncommon/SusSVN/sus/trunk/HLTS/Common/Data/allhltss_2025-08-25_SR3vsPR3Comparison_DampPat20percent_ALL_TFs.pdf r12615
/ligo/svncommon/SusSVN/sus/trunk/HLTS/Common/Data/allhltss_2025-08-25_SR3vsPR3Comparison_DampYat20percent_ALL_TFs.pdf r12614