Reports until 12:55, Tuesday 30 September 2025
H1 SUS
oli.patane@LIGO.ORG - posted 12:55, Tuesday 30 September 2025 (87228)
OSEMINF compensation filters updated to align with satamp swap: PR2 (M2, M3) and SR2 (M2, M3)

Continuing with our satamp swaps for the lower stages, Fil swapped out the M2 and M3 satamps for PR2 and SR2 today (87225). To properly compensate for this change, I used the TIA measurements Jeff took for each satamp's channels and used my script /ligo/svncommon/SusSVN/sus/trunk/Common/PythonTools/satampswap_bestpossible_filterupdate_ECR_E2400330.py to update the compensation filters (satampfilterupdate_output). I then checked that they looked good(PR2, SR2) and loaded them in.

Images attached to this report