Reports until 13:11, Tuesday 14 October 2025
H1 SUS
filiberto.clara@LIGO.ORG - posted 13:11, Tuesday 14 October 2025 - last comment - 11:42, Friday 24 October 2025(87469)
Sat Amps Modified: L2 (PUM) Stages for ETMX, ETMY, ITMX, and ITMY

WP 12836
ECR E2400330
Modified List T2500232

The following SUS SAT Amps were upgraded per ECR E2400330. Modification improves the whitening stage to reduce ADC noise from 0.05 to 10 Hz.

Suspension Old New OSEM
ETMX L2 (PUM) S1100146 S1100119 ULLLURLR
ETMY L2 (PUM) S1100137 S1100127 ULLLURLR
ITMX L2 (PUM) S1100135 S1100118 ULLLURLR
ITMY L2 (PUM) S1000277 S1100148 ULLLURLR


F. Clara, J. Kissel, O. Patane

Comments related to this report
oli.patane@LIGO.ORG - 17:22, Tuesday 14 October 2025 (87481)

Here's the characterization data and fit results for S1100148, assigned to ITMY L2's ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284. The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
plotresponse_S1100148_ITMY_L2_ULLLURLR_20250917.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are:

Optic  Stage  Serial_Number  Channel_Number  OSEM_Name  Zero_Pole_Hz  R_TIA_kOhm  Foton_Design 
ITMY L2 S1100148 CH1 UL 0.095:5.19 120.5 zpk([5.19],[0.095],1,"n")
      CH2 LL 0.0957:5.24 120.0 zpk([5.24],[0.0957],1,"n")
      CH3 UR 0.0958:5.24 120.125 zpk([5.24],[0.0958],1,"n")
      CH4 LR 0.0967:5.28 120.375 zpk([5.28],[0.0967],1,"n")

The attached plot and machine readable .txt file version of the above table are also found in ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/
2025-09-17_UKSatAmp_S1100148_D0901284-v5_fitresults.txt

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), Jeff nudged the transimpedance a bit to get the magnitude scale within the ~0.25%, shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.

Non-image files attached to this comment
oli.patane@LIGO.ORG - 17:19, Tuesday 14 October 2025 (87478)

Here's the characterization data and fit results for S1100119, assigned to ETMX L2's ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284. The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
plotresponse_S1100119_ETMX_L2_ULLLURLR_20250916.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are:

Optic  Stage  Serial_Number  Channel_Number  OSEM_Name  Zero_Pole_Hz  R_TIA_kOhm  Foton_Design 
ETMX L2 S1100119 CH1 UL 0.0949:5.19 120 zpk([5.19],[0.0949],1,"n")
      CH2 LL 0.0971:5.32 120 zpk([5.32],[0.0971],1,"n")
      CH3 UR 0.0964:5.27 120 zpk([5.27],[0.0964],1,"n")
      CH4 LR 0.0957:5.23 120 zpk([5.23],[0.0957],1,"n")

The attached plot and machine readable .txt file version of the above table are also found in ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/
2025-09-16_UKSatAmp_S1100119_D0901284-v5_fitresults.txt

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), Jeff nudged the transimpedance a bit to get the magnitude scale within the ~0.25%, shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.

Non-image files attached to this comment
oli.patane@LIGO.ORG - 17:18, Tuesday 14 October 2025 (87480)

Here's the characterization data and fit results for S1100118, assigned to ITMX L2's ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284. The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
plotresponse_S1100118_ITMX_L2_ULLLURLR_20250916.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are:

Optic  Stage  Serial_Number  Channel_Number  OSEM_Name  Zero_Pole_Hz  R_TIA_kOhm  Foton_Design 
ITMX L2 S1100118 CH1 UL 0.0966:5.27 120 zpk([5.27],[0.0966],1,"n")
      CH2 LL 0.0961:5.25 120 zpk([5.25],[0.0961],1,"n")
      CH3 UR 0.0963:5.26 120 zpk([5.26],[0.0963],1,"n")
      CH4 LR 0.097:5.3 120 zpk([5.3],[0.097],1,"n")

The attached plot and machine readable .txt file version of the above table are also found in ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/
2025-10-14_UKSatAmp_S1100118_D0901284-v5_fitresults.txt

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), Jeff nudged the transimpedance a bit to get the magnitude scale within the ~0.25%, shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.

Non-image files attached to this comment
oli.patane@LIGO.ORG - 17:21, Tuesday 14 October 2025 (87479)

Here's the characterization data and fit results for S1100127, assigned to ETMY L2's ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284. The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
plotresponse_S1100127_ETMY_L2_ULLLURLR_20250916.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are:

Optic  Stage  Serial_Number  Channel_Number  OSEM_Name  Zero_Pole_Hz  R_TIA_kOhm  Foton_Design 
ETMY L2 S1100127 CH1 UL 0.0963:5.26 121.25 zpk([5.26],[0.0963],1,"n")
      CH2 LL 0.0958:5.24 121.25 zpk([5.24],[0.0958],1,"n")
      CH3 UR 0.0952:5.2 121.25 zpk([5.2],[0.0952],1,"n")
      CH4 LR 0.0954:5.21 121.25 zpk([5.21],[0.0954],1,"n")

The attached plot and machine readable .txt file version of the above table are also found in ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/
2025-09-16_UKSatAmp_S1100127_D0901284-v5_fitresults.txt

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), Jeff nudged the transimpedance a bit to get the magnitude scale within the ~0.25%, shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.

Non-image files attached to this comment
filiberto.clara@LIGO.ORG - 11:26, Thursday 23 October 2025 (87685)

ITMY L2 (PUM) Sat Amp S1100148 installed on 10/14/2025. Replaced on 10/16/2024 with S1100080.

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=87515

oli.patane@LIGO.ORG - 11:42, Friday 24 October 2025 (87723)

Note that the satamp for ETMY L2 has now been swapped back to a S1100137, which has been modified for ECR E2400330

alog: 87722