Jeff, Oli
We made several updates to multiple SUS simulink models as a continuation of our work converting SUSB123 and SUSH34 into SUSB13 and SUSB2H34 (88765). Our changes were based on our updated G2301306-v10_PARTII - for the conversion from SUSB123 into SUSB13 for ITMY, we referenced slides 5, 7, 12, 13, 18, and 19. These changes were svn'd as r34388 and were installed and started last week (88781).
These are the changes we had to make for h1susitmy:
CDS Parameter Block:
- Changed hostname from h1susb123 to h1susb13
- Removed specific_cpu
Input (before, after):
- Removed ADC1 since now all OSEM channels are on ADC0
- Redid ADC to OSEM configuration
- Removed ITMY L3 BIO channel (coming from BS) from SHMEM
- Added ITMX L3 BIO channel (coming in from ITMX L3) to SHMEM since the L3 BIO is now on the ITMY model
Output (before, after):
- Changed DACs from several 20 bit DACs to two 28 bit DACs
- Lined up outputs to their corresponding DAC channels
- Lined up ESD bias and ESD sum outputs to their corresponding DAC channels
- Removed ITMY L3 BIO channel (that went out to BS) from SHMEM
- Added ITMX L3 BIO channel (that goes out to ITMX) to SHMEM since L3 BIO is now on the ITMY model
Binary I/O (before, after):
- Added ITMX L3 and ITMY L3 BIO inputs and routing into the ITMY_BIO_ENCODE block
- Added the ITMX L3 and ITMY L3 BIO out cards
- Added ITMX L3 and ITMY L3 BIO routing into the ITMY_BIO_DECODE block and outputs
- Removed the HWWD_CONTROL input from the ITMY_BIO_ENCODE block and removed the wire going into it from the ITMY_HWWD_BIN_OUT block since there is no physical cable there