Displaying report 1-1 of 1.
Reports until 12:20, Thursday 22 January 2026
H1 SUS (CDS)
oli.patane@LIGO.ORG - posted 12:20, Thursday 22 January 2026 (88814)
SUS Model Updates: h1susbs

Jeff, Oli

We made several updates to multiple SUS simulink models as a continuation of our work converting SUSB123 and SUSH34 into SUSB13 and SUSB2H34 (88765). Our changes were based on our updated G2301306-v10_PARTII - for the movement of the BS from SUSB123 to SUSB2H34, we referenced slides 5, 10, 12, 15, 18, and 21. These changes were svn'd as r34436 and were installed and started last week (88781).

These are the changes we had to make for h1susbs:

CDS Parameter Block:
- Changed dcuid
- Changed hostname from h1susb123 to h1susb2h34
- Removed specific_cpu

Input (before, after):
- Removed ADC1 since now all OSEM channels are on one ADC (called ADC1 in diagrams)
- Redid ADC to OSEM configuration
- Removed ITMX L3 and ITMY L3 channels from SHMEM that came in for ITM L3 BIO
- Added BS BIO channels for each BS stage (coming in from MC2) to SHMEM since the BS BIO is now on the MC2 model
- Redid BIO MON stage inputs into BS block to now read in values from SHMEM
    - MCDIO_2_BSM3 is terminated since current BS block doesnt have an M3 BIO

Output (before, after):
- Changed DACs from multiple 20 bit DACs to one 28 bit DAC
- Lined up outputs to their corresponding DAC channels
- Removed ITMX and ITMY L3 BIO channels that went out to ITMX and ITMY from SHMEM
- Added BS BIO channels for each BS stage (going out to MC2) to SHMEM since BS BIO is now on the MC2 model
- Redid BIO CTRL OUT outputs from BS block to now go out to SHMEM channels
    - BS M3 has a 0 coming in for now since current BS block doesn't have an M3 BIO

Binary I/O (before, after):
- Removed BIO blocks since BS BIO is now happening in the MC2 model

Images attached to this report
Non-image files attached to this report
Displaying report 1-1 of 1.