SUS Model Updates: h1susmc2

Jeff, Oli

We made several updates to multiple SUS simulink models as a continuation of our work converting SUSB123 and SUSH34 into SUSB13 and SUSB2H34 (88765). Our changes were based on our updated G2301306-v10_PARTII - for the conversion from SUSH34 into SUSB2H34 for MC2, we referenced slides 8, 10, 14, 15, 20, and 21. These changes were svn'd as r34384 and were installed and started last week (88781).

These are the changes we had to make for h1susmc2:

CDS Parameter Block:
- Changed hostname from h1sush34 to h1susb2h34
- Removed specific_cpu

Input (before, after):
- Removed ADC1 since now all OSEM channels are on ADC0
- Redid ADC to OSEM configuration
- Added BS BIO channels for each BS stage (coming in from BS) to SHMEM since the BS BIO is now on the MC2 model

Output (before, after):
- Changed DACs from multiple 18 bit DACs to one 28 bit DAC
- Lined up outputs to their corresponding DAC channels
- Added BS BIO channels for each BS stage (going out to BS) to SHMEM
- Changed ADC channels going to SR3 oplev in PCIE

Binary I/O (before, after):
- Added BS to BIO ENCODE and DECODE blocks
- Added BIO cards for BS
- Added inputs and outputs to BIO blocks for BS

Images attached to this report