Displaying report 1-1 of 1.
Reports until 12:21, Thursday 22 January 2026
H1 SUS (CDS)
oli.patane@LIGO.ORG - posted 12:21, Thursday 22 January 2026 (88820)
SUS Model Updates: h1susauxb2h34

Jeff, Oli

We made several updates to multiple SUS simulink models as a continuation of our work converting SUSB123 and SUSH34 into SUSB13 and SUSB2H34 (88765). Our changes were based on our updated G2301306-v10_PARTII - for the conversion from SUSH34 into SUSB13 for SUSAUXB2H34, we referenced slides 25 and 26. These changes were svn'd as r34398 and were installed and started last week (88781).

These are the changes we had to made for h1susauxb2h34 (previously called h1susauxh34):

CDS Parameter Block:
- Changed hostname from h1susauxh34 to h1susauxb2h34
- Removed specific_cpu

Input (before, after):
- Added ADC6 and ADC7
- Added BS block (taken from susauxb123)
- Connected ADC6 and ADC7 to BS block

BS Block (after):
- Connected up ADCs according to slide 26

Images attached to this report