Reports until 17:34, Thursday 22 January 2026
H1 SUS (CDS)
oli.patane@LIGO.ORG - posted 17:34, Thursday 22 January 2026 - last comment - 09:21, Tuesday 27 January 2026(88860)
Current Status of SUS-C1/C2 Racks vs Final O5 Build

J. Kissel, O. Patane, D. Barker, F. Clara, M. Pirello

Our big SUSB123 and SUSH34 to SUSB13 and SUSB2H34 upgrade last week wasn't the full upgrade for O5.
SUSB13 is fully upgraded to its O5 configuration, but for SUSB2H34, we can't fully upgrade to the final O5 build yet because we still need full control of the BSFM for the February commissioning period, whereas O5 will have the BSFM replaced with the BBSS (with QOSEMs instead of BOSEMs), requiring different electronics. The final O5 build will also include the electronics for the new suspensions LO1 and LO2. Going from the current configuration, which we call the "No QOSEMs/BBSS" configuration, to our final O5 build will require eight new chassis and two new ADC cards.

Since we will be needing to add/change things on the racks, that future upgrade will also come with user model additions/changes.

Table showing comparison diagrams

  Current “No QOSEMs/BBSS” Config Final O5 Config
Rack overviews slide31 slide33
DACs slide10 (excluding BS BOT/LO1/LO2 and AI in U13) slide10 (everything)
ADCs slide15 slide16
BIOs slide21 (excluding BS BOT chans) slide21 (everything)
AUX ADCs slide26 (excluding pink) slide26 (everything)

I've also attached the slides above in pdf form here. The full slides outlining all the changes O4 -> now -> O5 can be found here.

Changes needed to go from current configuration to final O5 configuration:
SUS-C1
    U33:: Remove cable inputs for (BSFM) BS M1 OSEM sensors, re-arrange cable inputs for BS M3 Oplev to make room for (BBSS) BS M3 OSEM sensors, and bring in PR3 M3 Oplev because we can
    U14:: Add (BBSS) BS M3 input for Binary Output
    U13:: Add (BBSS) BS M3 input for Binary Input
    U5 :: New D090006 TACQ Driver for (BBSS) BS M3

SUS-C2
    U22:: Add (BBSS) BS M3 Noisemon and (BBSS) BS M3 SFVmon inputs
    U20:: New D0902783 AA Chassis for LO1 M1 and LO2 M1 HAM-A Coil Driver Volt Monitors
    U16:: New D1300282 AA Chassis for (BBSS) BS M1 QOSEM sensors and LO1 M1 and LO2 M1 OSEM sensors
    U14:: Add (BBSS) BS M3 input to AI chassis
    U13:: New D2500353 AI Chassis for LO1 and LO2 Coil Actuation
    U9 :: New D1100687-v1 (100 Ohm Output Impedance) HAMA Coil Driver for LO1 M1 F1F2F3SD
    U8 :: New D1100687-v1 (100 Ohm Output Impedance) HAMA Coil Driver for LO1 M1 LFRTxxxx
    U6 :: New D1100687-v1 (100 Ohm Output Impedance) HAMA Coil Driver for LO2 M1 F1F2F3SD
    U5 :: New D1100687-v1 (100 Ohm Output Impedance) HAMA Coil Driver for LO1 M1 LFRTxxxx
    
susb2h34 IO Chassis
    Needs an additional ADC Card (and adapter card and internal SCSI cable)

susauxb2h34 IO Chassis
    Needs an additional ADC Card (and adapter card and internal SCSI Cable)

Images attached to this report
Non-image files attached to this report
Comments related to this report
oli.patane@LIGO.ORG - 09:21, Tuesday 27 January 2026 (88908)

To clarify a bit on the status of SUSB13 and SUSB2H34, "as of these Jan 2026 changes, the SUSB13 racks and IO chassis are 'fully upgraded,’ as only the ITM QUADs are left in this system and there are no changes to the QUAD control system electronics for O5, and we’ve now upgraded the whole chassis to use 28-bit 32CH LIGO DACs. For the SUSB2H34 racks and IO chassis, while we’ve imported the existing BSFM beam splitter control system electronics, that’s all we can do at this point and we need the BS under control as it was for the Feb 2026 commissioning period. After that’s done, and as the suspensions get installed, we’ll add electronics to upgrade the BSFM BS to become a BBSS BS (with M1 QOSEMs replacing the M1 BOSEMs, and new M3 OSEMs for sensing and control there), and we install the LO1 and LO2 HRTS electronics for BHD as needed. So, it may be a while before the wiring diagrams match reality again".

(Thanks to Jeff for the clearer wording!)