When I walked up to the TCSX chiller the Ruler was on the ground. But judging by the remnants of the adheisive and the Max Level sticker I'd wager that the water level was greater than 30.
| TCS X | TCS Y | |
|---|---|---|
| Previous Level | >30 | 10 |
| New Level | >30.0 | 10 |
| Water added | 0mL | 0mL |
I also went back to clean up the old adhesives and apply some new double sided tape to the ruler. So it should stop falling now.
ENDY Station Measurement:
During the Tuesday maintenace, the PCAL team (Jennie W. and I) went to ENDY with WSH (PS4) and took an End station measurement.
The ENDY Station Measurement was Mostly carried out according to the procedure outlined in Document LIGO-T1500062-v15. Except for the very last measurment. Rick and I have spoken about trying to reduce the light entering the Rx Sphere during a background measurement similar to measurment #9 by placing the normal PCAL enclosure covers back on before the start of the background. I somehow misinterpreted his suggestions and put the covers on for measurement #9. This change was hand written in to the measurment document LIGO-T1500062-v15 and is attached. Once we started to do the analysis I realized that Putting the covers on for Measurement #9 was a blunder because; only the measurement #9 was covered with pannels. Which means we won't be subtracting enough light from the rest of the measurements #7 and #8. Effectively ruining this measurement. So this needs to be it's own measurement on future attempts to take backgrounds with the covers on.
Before I touched anything, I took a pictures of the beam spot.
Martel:
We started by setting up a Martel Voltage source to apply some voltage into the PCAL Chassis's Input 1 channel and we record the times that a -4.000V, -2.000V and a 0.000V signal was sent to the Chassis. The analysis code that we run after we return uses the GPS times, grabs the data and created the Martel_Voltage_Test.png graph. We also did a measurement of the Martel's voltages in the PCAL lab to calculate the ADC conversion factor, which is included on the document.
There was also another error in the data when we were at the end station taking the measurement. Which lead to the BadTimeEy.pdf which is attached. A number of the plots during the time marked on the Document either had no data or had some "disturbance" during the time indicated on the document for measurment #2. We able to "salvage" some of this data by reducing the duration of our measurements from 240 seconds to 78 seconds and change the gpstime on measurment #2 to get usable data for all plots.
New Measurement #2 GPSstart time is now: 1368291685.
After the Martel, measurement the procedure walks us through the steps required to make a series of plots while the Working Standard is in the Transmitter Module. These plots are shown in WS_at_TX.png.
Next steps include: WS in the Receiver Module, These plots are shown in WS_at_RX.png.
Followed by TX_RX.png which are plots of the Tranmitter module and the receiver module operation without the WS in the beam path at all.
The last picture is of the Beam spot after we had finished the measurement.
All of this data is then used to generate LHO_ENDY_PD_ReportV2.pdf which is attached.
All data and Analysis has been commited to the SVN.
https://svn.ligo.caltech.edu/svn/aligocalibration/trunk/Projects/PhotonCalibrator/measurements/LHO_ENDY/
Last Tuesday during maintenance time I took transfer function measurements on SUS OMC to check it's health and functionality after SD & RT OSEM were found to be not working - see LHO alog 69500 for details. The TF results for all six dof are shown in the plots here. I think they look healthy and functional (I have compared it against last 3 years of measurements).
There is some cross-coupling seen in Roll dof (coming from Vertical dof) and Yaw dof (coming from Pitch dof) however Jeff Kissel believes they should be nicely damped when the damping loops are ON. The magnitude for Pitch dof has also dropped by a factor of four (from 2020 data, orange line) - is that a cause of concern for us?. I would also like to mention that during this measurement I got the coil driver state wrong (analog low pass was left ON, for double stage suspension like OMC LP should be OFF while taking TF) and secondly the coherence wasn't great (was getting saturations in DAQ output and I tried my best in the limited time to optimized the excitation amplitude). I am also attaching individual OSEM data below.
The templates are stored at the following location,
/ligo/svncommon/SusSVN/sus/trunk/OMCS/H1/OMC/SAGM1/Data
2023-05-16_2000_H1SUSOMC_M1_WhiteNoise_L_0p02to50Hz.xml
2023-05-16_2000_H1SUSOMC_M1_WhiteNoise_P_0p02to50Hz.xml
2023-05-16_2000_H1SUSOMC_M1_WhiteNoise_R_0p02to50Hz.xml
2023-05-16_2000_H1SUSOMC_M1_WhiteNoise_T_0p02to50Hz.xml
2023-05-16_2000_H1SUSOMC_M1_WhiteNoise_V_0p02to50Hz.xml
2023-05-16_2000_H1SUSOMC_M1_WhiteNoise_Y_0p02to50Hz.xml
The above measurements were taken with a bw of 0.03Hz. All the nominal settings were restored after the measurements were done.
Thu May 18 10:09:49 2023 INFO: Fill completed in 9min 48secs
Gerardo confirmed a good fill curbside.
I have installed a 'hwinj' application at both sites that handle opportunistic hardware injections for the detchar and stochastic groups:
The command takes two arguments: the injection group (in this case "detchar" or "stochastic"), and a specific injection name. The available injection names/waveforms are configured in the hwinj.yaml config file. By default injections are scheduledf or 10 seconds after the command is executed. You need to pass the '--run' option to actually execute the injection (see --help for more info). The detchar injection will be followed by a GraceDB upload, and the script should handle automatically fetching the authentication cert for the user executing it. The '--dry' option can be used to test everything without actually initiating the injection or gracedb upload.
These injections should happen in nominal low noise. Assuming everything is configured correctly and the DIAG_EXEC guardian nodes are properly tied into the overall guardian IFO status, initiation of these nodes should take us out of OBSERVING automatically.
The setup current supports three different injections, one "safety" injection for detchar (~7 min), and a long (30 min) and short (13 min) injection for the stochastic group. The relevant injection commands would then be:
We should coordinate with the detchar and stochastic groups to run these injections during this last week of engineering run.
Before performing the Detchar Safety injections, please go through the checks in this google document.
TITLE: 05/18 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 130Mpc
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 2mph Gusts, 1mph 5min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.09 μm/s
QUICK SUMMARY:
H1 has been locked for almost 4hrs (w/ Jenne fixing squeezing 2hrs into the lock to optimize sensitivity. It currently is in Observing and will stay so until PEM Team is ready to work with H1. I have taken GRD IFO to MANAGED.
On OPS Overview the SEI EY HEPI Pump pressure has been RED. On CDS Overview we have excitations on for CalInj (which is "blue" not "red"), OMC, CalEY).
Nuc30's DARM dtt looks to have crashed again (Jenne restarted remotely), and I just resized it.
This morning, H1 was not in Observing because the squeezer was not injecting squeezing. I requested the Sqz_manager to DOWN, then FREQ_DEP_SQZ. That worked, and the IFO automatically flipped to Observing.
Since we increased the SHG power on Tuesday (69671) the FC launch power almost doubled, 3mW to 6mW see attached. I have increased the sqzparams.fcgs_trans_lock_threshold from 50 to 110uW (was recently reduced from 80uW to allow FC to lock with low SHG) and reloaded SQZ_FC to stop this happening again.
We should think about if we want 6mW into FC launch and if we've always had this much power in higher order modes in the FC. There hasn't been any ZM2 PSAMS changes since the end of April.
TJ noted the SQZ_LO_LR guardian was unhappy at the time the FC unlocked, this is because the OPO unlocked and SQZ_MANAGER jumped to LOCK_OPO_AND_FC but didn't run though the DOWN state so BDiv stayed open and LO locking, I added a turn_off_sqz() line to LOCK_OPO_AND_FC. We should check there aren't more jump states that need this added.
Like Sheila and Camilla found, the first hours-long squeezer lockloss was due to FC locking on a LG01 donut mode. Their solution to increase the green lock threshold was great! Daniel and I have also updated the nominal FC GREEN TRANS value in slowcontrols, H1:SQZ-FC_TRANS_C_DC_NOMINAL.
Additionally though, FC guardian should have brought itself down b/c the beam clearly failed the TEM00 mode-checker decorator. This function looks at the FC TRANS GREEN camera's gaussian widths of the beam waist, H1:VID-FC_TRANS_C_{WX,WY} to check TEM00. Daniel and I also fixed this secondary bug, so now we should be doing check_TEM00() in the SQZ_FC guardian again. See the bottom trends: FC green trans was above its lock threshold (SQZ_FC_TRANS_C_LF_OUTPUT), but the beam's fitted waists were about 2x bigger than normal -- however, this didn't trigger FC to relock because of a stray "else" statement error in the guardian code logic. This should now be fixed, and we will monitor.
The second sqz lockloss could have happened because the OPO PZT voltage bottomed out, see the top trend here when SQZ_MANAGER went down. Not sure this is related to lab temp changes of even 0.5C. We've previously addressed this same issue for the SHG PZT in 69366. What I've done to address this: to deal with OPO PZT bottoming out in the future, I've edited SQZ_MANAGER to relock the OPO if its voltage is too low, and we're not squeezing. Specifically, I've upgraded "@SHG_PZT_checker" to a general "@PZT_checker" which now checks both SHG + OPO PZTs in the SQZ_READY_IFO state. And, in the "LOCK_OPO_AND_CLF" state, if not OPO_PZT_OK() (b/c its too low), the opo will re-lock.
From TJ and Camilla's investigations above, I checked and I don't think there are more jump states that need to "turn_off_sqz()"; in fact only DOWN and LOCK_TTFSS are goto=True states, and not LOCK_OPO_AND_FC. In turn_off_sqz(), I added a 1 second sleep timer to let the beam diverter close before moving on to relock the squeezer.
TITLE: 05/17 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 134 Mpc
SHIFT SUMMARY:
- Came into to a relocking IFO only to be delayed by an EQ (Guatemala - 6.4), holding in READY until ground motion has calmed down
- Lock #1:
- The IFO is currently going on a 5 hour stretch, leaving the IFO in OBSERVE, relatively quiet night tonight :)
LOG:
No log for this shift.
Took H1 to NLN_CAL_MEAS to run Calibration Suite Measurements.
Attached is a screenshot of the sitemap > CAL CS > Calibration Monitor screen shortly after starting the measurement.
'pydarm report' command gave attached report:
Since the PEM accelerometers were installed on SQZT 0+7 a couple days ago (in-table locations in 69671), I checked table coherences with some relevant SQZ signals I could think of. A couple interesting finds, but don't totally know what to make of them yet:
The IFO has been locked for 1:20 and PEM injections are currently ongoing.
After finishing an initial alignment and trying to lock ALS, we can into an issue regarding ALS X. The ALS guardian was complaining about a low beatnote. I tried to troubleshoot this by adjusting the crystal frequency to get the fiber lock beat frequency (top left of PLL overview) to ~39 MHz, but the value would just go bad again shortly after. After talking with Shiela, she suggested we lower the Beatnote RF minimum to -15 from -10 (found on the bottom right of the PLL overview sceen), and this seemed to do the trick. The scope attached is the recent trend of the beatnote in question, which in the past hour has gotten very poor, which is interesting because this was around the time the initial alignment was being done.
Update: Further up into the lock, it seems that the beat note is improving? Strange - scope attached
Naoki, Daniel, Vicky
Today we re-installed the mini-circuits amplifier, a ZHL-500HLN+, onto the CLF RF6 PD, cable ISC_SQ_222. This reverts the change from Jan. 27, 2023 (LHO:67038), when we went to a high CLF configuration to study what the problem of high CLF powers. Now for O4, we want to nominally operate with very low CLF powers, so we have reverted to dumping 95% of the optical power into the fiber as designed on SQZT0 (69457), and today restored this RF amplifier to the RF6 path. I think this now reverts up the major CLF path changes we made to study high-CLF issues prior to starting O4.
With the same 6uW of optical power incident on the RF6 PD, we now have CLF_REFL_RF6_DEMOD_RFMON = -26 (was -47) on a noise floor of -52 (was -55), see the trends here. I think we can now afford to turn down the CLF powers a bit more.
With 6uW on CLF_REFL and this added +21dB RF6 power, we re-measured the CLF transfer function. Here, we measured UGF ~ 2.4 kHz and phase -159, with CLF CMB gains set as: common gain = 15 (was 22), and fast gain = 6 (was 31), consistent with when we previously used this exact amplifer. The CLF path should be back to its nominal low-power configuration now for O4, and we explore lower-power CLF operation when IFO relocks.
To re-lock the OPO on CLF+GREEN dual resonance, now that the amplifier is adding +21dB gain to the CLF RF6 signal, I updated the nominal CLF RF trigger level (H1:SQZ-OPO_IR_RESONANCE_CLF_NOM = 0.005 (up from 0.0009)) to re-lock the OPO on dual resonance, state "LOCKED_CLF_DUAL". This setting is pretty sneaky, but can be found in medms from SQZ7 >> OPO IR (bottom right corner box), see screenshot. The updated CLF RF Nominal value is saved in SDF.
I noticed and fixed this as I relocked the squeezer just before Observing tonight, to pre-empt the OPO PZT (H1:SQZ-OPO_PZT_1_VOLTS) bottoming out in a couple hours (it was at 45V, it loses lock usually below 40V; this PZT is nominally between 70-110V).
A while ago we used the ifr RF synthesizer to drive the LO of the homodyne. This was still running. We now turned the ifr unit off and put the homodyne LO back to the 3.125MHz distribution amplifier.
After the calibration update this morning, I need to retrain the NonSENS noise cleaning. However, the NDS team is still in progress on understanding why we can't get past GDS-CALIB_STRAIN channels right now. Once we can get that past data, I should be able to retrain. Until then, the NOISE_EST is zeros, so GDS-CALIB_STRAIN_CLEAN will be the same as GDS-CALIB_STRAIN_NOLINES.
This doesn't look like it'll get fixed tonight, as it may require a restart of the gstlal-calibration pipeline. I've set the NOISE_CLEANING guardian to have a gain of 0 in the WHITENING_NOISE_EST channel, and accepted it as zero in both safe and observe.
This means that while this is true, GDS-CALIB_STRAIN_CLEAN will be the same as GDS-CALIB_STRAIN_NOLINES.
After the newest calib fix and restart that fixed the nonsens subtraction channel (but didn't affect any other parts of the calib), I retrained the jitter subtraction (but not yet retrained the LSC subtraction). The jitter subtraction should be running, and I've accepted the SDFs in both safe and observe.
See attached for the effect, including I've got a bit of noise re-injection that I didn't expect.
Jennie, Sheila
Sheila and I looked at the steps Elenna changed the DARM offset through, the last time the contrast defect measurement was taken (see LHO #69361). To get an idea of how much light seen at the anti-symmetric port (calibrated in terms of power into HAM6) is insensitive to DARM motion I plotted the scaling of the light at ASC-AS_C_NSUM_OUTPUT with DARM offset changing (OMC-DCPD_SUM_OUTPUT).
| DARM offset (mA) (OMC-DCPD_SUM_OUTPUT) |
Power out of SRC (ASC-AS_C_NSUM_OUTPUT) (+/- 0.00945792) |
Time offset changed |
| 19.91 | 0.8655 | - |
| 6.760 | 0.8467 | 1367176162 |
| 10.62 | 0.8519 | 1367176288 |
| 15.15 | 0.8589 | 1367176413 |
| 20.82 | 0.8666 | 1367176538 |
| 27.17 | 0.8755 | 1367176663 |
| 34.15 | 0.8857 | 1367176788 |
Attached is the plot (pdf) of total power into HAM 6 versus the power that gets through the OMC.
The uncertainty in the AS measurement is was estimated using the y cursors on ndscope (shown in png).
0.837W of power is predicted for no DARM offset, and 82% of the light coming into HAM 6 is sensed by the OMC DCPDs.
We also tried to use the total power on OMC REFL to do a similar calculation of the light rejected from the OMC that is insensitive to DARM motion but due the noise on this signal we made need bigger DARM offset steps to see a clear trend.
Since this measurement, whitening has been implemented on the OMC REFL PD by Daniel.
Code is Plot_OMC_REFL_2023-05-12.ipynb in /ligo/home/jennifer.wright/git/OMC_mode_matching/
Figure is in /ligo/home/jennifer.wright/git/OMC_mode_matching/figures
In the SQZ loss budget, HAM6 losses are OM1 (99.3%) OM3 (98.5%), OMC transmission (95/7% measured before installation), and DCPD QE (98% in budget, should be 99%). This gives an expected HAM6 throughput of 92%, which means we are missing 11% loss, including OMC mode mismatch and any degredation of the OMC transmission or PD QE.
See 60885 and the comment above it for a similar measurement from LLO.
Just to clarify, that's 82% of carrier light that gets through the OMC from the input of HAM 6.
Jennie W, Sheila D
We reviewed some alogs and dcc documents about OMC losses, OMC cavity scans suggest that our OMC transmission has degraded from 96% to 92%.
Testing before installation results start on page 140: T1500060 The input output coupler transmission (T) is 7690ppm, 50ppm loss per mirror.
Finesse = pi/(1-r1*r2*rloss) (approximation) with r1=r2 = sqrt(1-T) and rloss is an amplitude reflectivity that represents all the cavity losses.
round trip loss = 1-[(1-pi/F)/(1-T)]^2
cavity transmission = T^2 * (Finesse/pi)^2
I've updated the SQZ Loss wiki, if we assume the OMC transmission is 92%, our known IFO output losses become 13%, and our known squeezing losses become 19%.
Redoing the comparison above of Jennie's HAM6 throughput estimate (82%) to the 12% known HAM6 losses:
Implies that we have 7% unknown HAM6 losses, which could be OMC mode matching.
Testing documents page 143: reports 4690ppm transmission of the input and output couplers, and summing the losses 284ppm, implies finesse of 401 and cavity transmission of 96.4%
Minor comment: This line should be identical to P.140. The transmission of the input/output couplers should be 7690ppm. Did I give you a link to an old document...?