Displaying reports 3761-3780 of 88171.Go to page Start 185 186 187 188 189 190 191 192 193 End
Reports until 14:56, Friday 12 September 2025
H1 SUS
anthony.sanchez@LIGO.ORG - posted 14:56, Friday 12 September 2025 (86887)
Weekly In-Lock SUS Charge Measurement Analysis

ls /opt/rtcds/userapps/release/sus/common/scripts/quad/InLockChargeMeasurements/rec_LHO  -lt | head -n 6
total 295
-rw-r--r-- 1 guardian           controls  160 Sep  9 07:58 ETMX_12_Hz_1441465134.txt
-rw-r--r-- 1 guardian           controls  160 Sep  9 07:50 ETMY_12_Hz_1441464662.txt
-rw-r--r-- 1 guardian           controls  160 Sep  9 07:50 ITMY_15_Hz_1441464646.txt
-rw-r--r-- 1 guardian           controls  160 Sep  9 07:50 ITMX_13_Hz_1441464644.txt
-rw-r--r-- 1 guardian           controls  160 Sep  2 07:58 ETMX_12_Hz_1440860334.txt

In-Lock SUS Charge Measurements did indeed run this Tuesday.

python3 all_single_charge_meas_noplots.py

Cannot calculate beta/beta2 because some measurements failed or have insufficient coherence!
Cannot calculate alpha/gamma because some measurements failed or have insufficient coherence!
Something went wrong with analysis, skipping ITMX_13_Hz_1440859844

 


 

Images attached to this report
H1 General
anthony.sanchez@LIGO.ORG - posted 14:41, Friday 12 September 2025 (86851)
DRMI Histograms

Ive put togther a number of Histograms that can be used for quick glance of locking state performance marks.

Sheila & Elenna wanted some DRMI Stats dating back to Aug 19th .

Images attached to this report
Non-image files attached to this report
H1 IOO
elenna.capote@LIGO.ORG - posted 13:57, Friday 12 September 2025 - last comment - 17:15, Friday 12 September 2025(86884)
Power on IMC REFL reduced

Sheila and I went out to IOT2L. We measured the power before and after the splitter called "IO_MCR_BS1" in this diagram of IOT2L. This is listed as a 50/50 beamsplitter. However, there is no possible way it can be, because we measure about 2.7 mW just before that splitter, and 2.45 mW on the IMC refl path and 0.25 mW on the WFS path. So we think it must be a 90/10.

Sheila then adjusted the have wave plate upstream of this splitter so that the light on IMC refl dropped from 2.4 mW to 1.2 mW., as measured from the IMC refl diode.

Comments related to this report
elenna.capote@LIGO.ORG - 14:22, Friday 12 September 2025 (86885)

We compensated this change by raising the IMC gains by 6 dB in the guardian. I doubled all the IMC WFS input matrix gains, SDF attached.

Images attached to this comment
elenna.capote@LIGO.ORG - 14:33, Friday 12 September 2025 (86886)

SDFed the IMC PZT position that we think we like.

Images attached to this comment
ryan.short@LIGO.ORG - 17:15, Friday 12 September 2025 (86892)

After the waveplate adjustment and updating of gains in Guardian, we took an IMC OLG measurement with the IMC locked at 2W input. The UGF was measured at 35.0 kHz.

Non-image files attached to this comment
H1 ISC (ISC, PSL)
keita.kawabe@LIGO.ORG - posted 12:54, Friday 12 September 2025 (86882)
Alignment change on the PSL table

(In the attached 1 week trend, [-7 day, -2 day] range is before the power outage and [-1day, 0 day] is after the long high power lock post power outage. Ignore [-2 day, -1 day] because the ISS 2nd loop was messing with the AOM during that time.)

ISS QPD (top right) shows a clearly measurable shift in the alignment mostly in DX (YAW). The QPD is downstream of the PMC, the calibration is supposed to be in mm so nominally it's just 5.4 um but there's a focusing lens in front of it and unfortunately I don't know the focal length nor the distance between the lens and the QPD for now, so the only thing I can say is that the alignment changed downstream of PMC in YAW.

BEA (Bull's Eye Sensor, top left) also shows an alignment shift upstream of PMC. Input matrix of this one is funny, don't read too much into the magnitude of the change. I'm not even sure if it was mostly in PIT or in YAW. (The beam size,  2nd from the top on the left column, also shows a change but I won't trust that because that output is supposed to change when there's an alignment change.)

Images attached to this report
H1 IOO
sheila.dwyer@LIGO.ORG - posted 12:53, Friday 12 September 2025 (86881)
IMC visibility not degrading further today

In our first long lock after the power outage, ISS second loop increased the input power to the IMC by 0.1 W/ hour for 10 hours, MC2 trans was stable, and IMC refl DC increased by 1.7 (mW) per hour (first screenshot)

Last night we left the IMC at 2W, and saw no further degredation. (second screenshot).

Now we increased the power to 60W for an hour and see no further degredation after the transient while the ASC was moving and maybe there was a thermal transient.  (third screenshot)

Images attached to this report
H1 ISC
camilla.compton@LIGO.ORG - posted 12:14, Friday 12 September 2025 - last comment - 12:55, Friday 12 September 2025(86880)
Power on IMC REFL RF PD has increased, plan to decrease it so PD continues to work well

Daniel suggested that as the power has increased on the IMC REFL PD (IOT2L D1300357) by a factor of around 3, was 19mW at 60W in, now 60mW at 60Win, we should reduce the power on this diode as it doesn't work well with high powers. H1:IMC-REFL_DC_OUT16

At 2W input, it was 0.73mW, is now 2mW. Aim for a factor of 2 reduction (to make it simple to reduce electronics gains).

Aim to reduce power on IMC REFL to 1mW using IOT2L waveplate when there is 2W incident on IMC.

Comments related to this report
camilla.compton@LIGO.ORG - 12:55, Friday 12 September 2025 (86883)

Decided we should do this with the IMC OFFLINE. Ryan S put 0.1W into the IMC with the PSL waveplate. This gives 2.37mW on H1:IMC-REFL_DC_OUT16.

Aim to reduce this by a factor of 2 to 1.18mW.

H1 IOO
elenna.capote@LIGO.ORG - posted 11:44, Friday 12 September 2025 (86879)
Change in IMC visibility

A quick calculation of the IMC visibility:

Before power outage:

IMC refl when offline = 46.9

IMC refl when online at 2 W = 0.815

1 - 0.815/46.9 = 0.982

After power outage:

IMC refl when offline = 46.5

IMC refl when online at 2 W = 2.02

1 - 2.02/46.5 = 0.965

So we think we have lost 2.6% of the visibility

H1 DetChar (DetChar, DetChar-Request)
elenna.capote@LIGO.ORG - posted 11:32, Friday 12 September 2025 - last comment - 10:20, Monday 15 September 2025(86878)
Detchar request- help understanding our IMC-related glitches.

I posted the following message in the Detchar-LHO mattermost channel:

Hey detchar! We could use a hand with some analysis on the presence and character of the glitches we have been seeing since our power outage Wednesday. They were first reported here: https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=86848 We think these glitches are related to some change in the input mode cleaner since the power outage, and we are doing various tests like changing alignment and power, engaging or disengaging various controls loops, etc. We would like to know if the glitches change from these tests.

We were in observing from roughly GPS time 1441604501 to 1441641835 after the power outage, with these glitches and broadband excess noise from jitter present. The previous observing period from roughly GPS 1441529876 to 1441566016 was before the power outage and these glitches and broadband noise were not present, so it should provide a good reference time if needed.

After the power outage, we turned off the intensity stabilization loop (ISS) to see if that was contributing to the glitches. From 1441642051 to 1441644851, the ISS was ON. Then, from 1441645025 to 1441647602 the ISS was OFF.

Starting from 1441658688, we decided to leave the input mode cleaner (IMC) locked with 2 W input power and no ISS loop engaged. Then, starting at 1441735428, we increased the power to the IMC from 2 W to 60 W, and engaged the ISS. This is where we are sitting now. Since the interferometer is has been unlocked since yesterday, I think the best witness channels out of lock will be the IMC channels themselves, like the IMC wavefront sensors (WFS), which Derek reports are a witness for the glitches in the alog I linked above.

Comments related to this report
elenna.capote@LIGO.ORG - 10:20, Monday 15 September 2025 (86927)

To add to this investigation:

We attenuated the power on IMC refl, as reported in alog 86884. We have not gone back to 60 W since, but it would be interesting to know if a) there was glitches in the IMC channels at 2W before the attenuation, and b) if there were glitches at 2 W after the attenuation. We can also take the input power to 60 W without locking to check if the glitches are still present.

H1 IOO
sheila.dwyer@LIGO.ORG - posted 11:30, Friday 12 September 2025 (86877)
IMC OLG measurement comparison

Ryan S, Keita, Oli, Sheila

Using the instructions found here we used the netgpib script to get data from an IMC OLG measurement (already checked yesterday 86852). 

Oli and I adapted Craig's quick tf plot script to plot two TFs on top of each other, and found some data from Oct 31st 2024 where the IMC OLG was measured with 2W input power 80979

We adjusted the gain of the 2024 measurement to match the gain of the 2024 measurement to today's for the first point.  The IMC cavity pole is at 8.8kHz, so since this measurement cuts off at 10kHz it will be difficult to get information about the IMC cavity pole from this measurement. 

This script is in sheila.dwyer/IOO/IMC_OLG/quick_2tfs_plot.py,  legend entries and file names are hardcoded not arguments.

 

Non-image files attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:53, Friday 12 September 2025 (86876)
Fri CP1 Fill

Fri Sep 12 10:08:39 2025 INFO: Fill completed in 8min 35secs

 

Images attached to this report
LHO General
ryan.short@LIGO.ORG - posted 07:41, Friday 12 September 2025 - last comment - 08:19, Friday 12 September 2025(86871)
Ops Day Shift Start

TITLE: 09/12 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 2mph Gusts, 1mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.16 μm/s
QUICK SUMMARY: No observing time for H1 overnight. Investigations will continue today into issues caused by the site power outage on Wednesday.

Comments related to this report
ryan.short@LIGO.ORG - 07:59, Friday 12 September 2025 (86873)

Things looking relatively stable overnight. Some trends and current snapshot of MC TRANS and REFL attached.

Images attached to this comment
sheila.dwyer@LIGO.ORG - 08:19, Friday 12 September 2025 (86875)

Here's an image of a time when the IMC was locked at 2W before the power outage to compare to: archive screenshot

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 19:20, Thursday 11 September 2025 (86870)
OPS Eve Shift Summary

TITLE: 09/12 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: NONE
SHIFT SUMMARY:

IFO is in DOWN and MAINTENANCE

We are still working on figuring out what happened post-outage that is yielding a glitchy interferometer when locked.

Due to the risk of damaging the interferometer, the decision has been made to cancel the OWL shift, shorten the EVE shift and stay in DOWN until tomorrow.

PSL Dust is fluctuating but has been increasing in the last 2-3 hours. I assume that this is due to the PSL work that was done 2/3 hours ago - this has not been an issue in the past though I've attached a plot.

LOG:

None

Images attached to this report
LHO FMCS (PEM)
ibrahim.abouelfettouh@LIGO.ORG - posted 19:01, Thursday 11 September 2025 (86869)
Checking HVAC Fans - Weekly FAMIS 26686

Closes FAMIS 26686. Last checked in alog 86718

Everything below threshold with the outage clearly visible as a blip (mostly in MY and MX fans).

Plots attached.

Images attached to this report
H1 ISC
oli.patane@LIGO.ORG - posted 18:09, Thursday 11 September 2025 - last comment - 08:01, Friday 12 September 2025(86866)
Glitch rate from overnight lock

Originally pointed out by Camilla or Elenna earlier today, but I wanted to record it here in case it can help us figure out what the issue is. During last night's low range lock after the power outage (2025-09-11 03:00:47 - 17:42:34 UTC), our glitch rate was way higher than it typically is, and the glitches were mainly confined to several specific frequencies(main summary page, glitches page). I've been able to get some of these frequencies, but there are some frequency lines that I haven't been able to narrow in on the exact frequencies yet.

Here are the frequencies I confirmed, as well as guesses for the other lines:
16.91
24-ish
29.37
37.32
47.41
60-ish
76-ish
90-ish
120-ish
156.97
199.44
250-ish
321.95
409.04
510-ish
660.30

I've plotted them just lined up next to each other as well as plotting the difference in frequency as compared to each one's previous point, and we can see there is a slow exponential increase in the difference between each glitch line frequency. The yellow points are the ones that are around the correct range, but not their exact values.

Additionally, once we turned the ISS Second Loop off at 16:55 UTC, the glitches previously appearing between 500 and 1000 Hz stopped almost altogether, the glitches at 409 Hz and below became a lot more common and louder, and we also saw some extra glitches start above 4000 Hz. We understand the glitches above 4000 Hz, but we aren't sure why the glitches between 500 and 4000 Hz would stop when we did this.

Hoping this might help shine a light on some possible electronics issue?

Images attached to this report
Comments related to this report
derek.davis@LIGO.ORG - 08:01, Friday 12 September 2025 (86874)

The exponential behavior noted in this alog is related to how frequencies are chosen for the sine-Gaussian wavelets used by Omicron. This type of frequency behavior is what we would expect for broadband glitches, and unfortunately, it does not relate to their physical source in this case. 

H1 CDS
david.barker@LIGO.ORG - posted 12:24, Wednesday 10 September 2025 - last comment - 07:51, Friday 12 September 2025(86827)
H1 is down due to power outage.

We had a site wide power outage around 12:11 local time. Recovery of CDS has started.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 12:40, Wednesday 10 September 2025 (86828)

I've turned the alarms system off, it was producing too much noise.

We are recovering front end models.

david.barker@LIGO.ORG - 13:51, Wednesday 10 September 2025 (86831)

Jonathan, Erik, Richard, Fil, Patrick, EJ, TJ, RyanS, Dave:

CDS is recovered. CDSSDF showing WAPs are on, FMCSSTAT showing LVEA temp change.

Images attached to this comment
david.barker@LIGO.ORG - 13:52, Wednesday 10 September 2025 (86832)

Alarms are back on (currently no active alarms). I had to restart the locklossalert.service, it had gotten stuck.

richard.mccarthy@LIGO.ORG - 07:51, Friday 12 September 2025 (86872)

BPA Dispatcher on duty said they had a breaker at the Benton substation open & reclose. At that time, they did not have a known cause for the breaker operation.  Hanford fire called to report a fire off Route 4 by Energy Northwest near the 115KV BPA power lines. After discussions with the BPA dispatcher the bump on the line or breaker operation, may have been caused by a fault on the BPA 115KV line causing the fire. BPA was dispatching a line crew to investigate.

 

Displaying reports 3761-3780 of 88171.Go to page Start 185 186 187 188 189 190 191 192 193 End