H1 ISC
sheila.dwyer@LIGO.ORG - posted 20:53, Friday 18 November 2016 - last comment - 02:35, Saturday 19 November 2016(31628)
back on refl WFS with alignment change, DC centering for REFL WFS not stable

We've been struggling to switch from POP X to REFL WFS, probably because with our low recycling gain we are near the point where the REFL WFS have a sign flip for PR3.  However, we know that we get bad scattered light coupling to DARM from ISCT1 if we leave the beam diverters open, so it would be good to switch to REFL WFS. TOday and last night we tried improving the recycling gain by changing the spot position on PR3, which makes the broad lump of noise from 200-1kHz come back.  We also have reduced range which is probably because the SRCL coupling changes and we need to update the feedforward.  I am hoping that we can see that the interferometer is stable in this configuration, and that we can get the range back to 75Mpc by retuning the FF if we get a long lock to measure the transfer function.  In that case we will have to decide if we are more bothered by jitter or the scattered light, or try jitter subtraction or TCS to help with the jitter. 

One wrinkle in this is that the REFL WFS centering for yaw seems to go unstable, probably because it is cross coupled with some of our ASC loops.  If you are an optimist you will believe this was actually the problem with the REFL WFS not the changing matrix, and that we can just go back to our low jiter/ low recycling gain alignment.  

Move PR3 spot position:

Yesterday we tried moving our spot position on PR3 as a way of increasing the recycling gain.  We have been operating at an alignment that gives us a recycling gain of around 30.5, but minimizes the broad jitter lump in DARM.  We are able to get a modest increase in recycing gain (to almost 30.7) by moving the PR3 spot in yaw, without causing any extra noise in DARM (this is the test that Nutsinee did last night). However, to get the best recycling gain (almost 31.6 ish) we need to also move pitch back in the direction that makes the broad jitter lump appear again.  The first attachment shows the range and recycling gain over the course of the 30 hour lock we just had, you can see that the range clearly drops when the recycling gain increases. 

The drop in range however is not due to the jitter peaks, but due to the very small change in the noise from 30-200Hz. The second attachment is a comparision of the spectra in these 2 configurations, in the good recycling gain example we had not retuned a2l which makes the noise below 25Hz bad in the blue trace. The third attachement shows the cumulative range difference, you can see what frequencies are responsible for the drop in range. The third attachment shows that in the higher recyclcing gain state we had more SRCL coherence at these frequencies, so it might be possible to recover the range with the higher recycling gain by retuning SRCL feedforward. 

The offsets to use in PRC1 to get to the recycling gain of 32 are 0.2 for pit and -0.109 for yaw. I have put these into the POP A offsets, old values were 0.44 for yaw, nothing for pit, new values are  0.2 for pit, 0.331 for yaw.  Cheryl was able to lock the interferometer this way without any updating of the inital alignment references. 

PR3 on REFL WFS:

This afternoon I measured the refl WFS sensing for PR3 in some uncalibrated units:  

  recycling gain 30.4 recycling gain 32
A9I pit 0.572 1.12
A45I pit

0.036

0.26
B9I pit

0.94

1.478
B45I pit -0.6 -0.642
A9I yaw -0.367 0.065
A45I yaw 0.026 -0.352
B9I yaw 0.795 1.232
B45I yaw -0.462 -0.407  

I used the signals for which there is a signal with the same sign in both measurements and not factors of 10 gain changes. 

I used an input matrix of 0.53 for REFL A 9I, 0.04 for REFLB9I and -0.092 for REFL B45I.  For yaw I switched it over using an input matrix of just refl B, 0.066 REFLB9I and -0.2 REFLB45I.  This gives us a ugf about a factor of 4 below what we use for POPX.  We have an instability at around 1.88 Hz when we sitch yaw over to REFL WFS with a higher bandwidth, I think it comes from the DC1_Y centering loop.  

DC1Y centering instability:

Last week Daniel and I worked on the refl centering loops with the interferometer off, (31382), the settings haven't changed but when I measured DC1Y with the full interferometer locked, something has changed for the worse as shown in the 5th attached screenshot.  One gues is that this is because the centering loops are cross coupled with our other ASC loops.

We can try to fix this by increasing the gain, for now I have removed the cut off filter from DC1Y, which only helps a little.  Having this off causes RM2 to saturate when we are locked at DC readout (the talker announces this as OM).  I also added a notch to PR2Y which only gets engaged when we switch to the REFL WFS, it would not be OK if we had a higher bandwidith.  This isn't a very good solution.  

The guardian is edited to put in the new matrix and engage the notch for now in PR3_REFL_WFS. If this is not stable you can just go back to skipping PR3_REFL_WFS and CLOSE_BEAM_DIVERTERS

Operator Request:  If the interferometer unlocks, could whomever is on shift measure the DC1Y centering loop?  

Images attached to this report
Non-image files attached to this report
Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 00:23, Saturday 19 November 2016 (31636)

Came to find Cheryl attempting an initial alignment but she reported that no alignment has been changed since the last lock. I let the ISC_LOCK Guardian take control again and did the measurement. I reverted the set up (turn input off for DC1 and 2, aligned ITMs and ETMs) then moved on to locking

.

Images attached to this comment
Non-image files attached to this comment
nutsinee.kijbunchoo@LIGO.ORG - 02:35, Saturday 19 November 2016 (31639)

And one more at DC_READOUT

Images attached to this comment
H1 General
cheryl.vorvick@LIGO.ORG - posted 20:35, Friday 18 November 2016 (31633)
running a2l

started at 4:21:51UTC

ended at 4:35:00UTC

H1 General (VE)
cheryl.vorvick@LIGO.ORG - posted 20:20, Friday 18 November 2016 - last comment - 20:57, Friday 18 November 2016(31632)
CP4 has been in and out of alarm today, multiple alarms since I arrived

Not sure if this was looked at earlier in the day, but CP4 has been in alarm off and on since 7:44AM PT.

Plot attached shows MX, CP5, not in alarm, on the left, and MY, CP4, going in and out of alarm on the right.

Second attachment is the alarm log.

Images attached to this report
Comments related to this report
chandra.romel@LIGO.ORG - 20:57, Friday 18 November 2016 (31634)
This is not normal behavior. Thank you for alerting me via text. TJ noted that CP4 generated an alarm yesterday morning too. The liquid level in the pump is sporadically noisy and causes the LLCV to jump up or down as a response. This noise seems to be real since we see it in the magnehelic pressure gauge at the pump. We will continue to monitor. 
H1 ISC
daniel.sigg@LIGO.ORG - posted 17:48, Friday 18 November 2016 (31631)
Jitter Measurements (Again)

The DBB shutter was opened to allow for more jitter measurements. The measurements are:

  1. File B: In lock for a long time (>24h), we see jitter coherence with DARM around 500 Hz as high as 0.35.
  2. File A: Moving to an alignment with higher power recycling gain (32 instead of 30.5) increased the coherence as high as 0.5.
  3. File C: At the beginning of the next lock the coherence was around 0.15.
  4. File D: Moving to the alignment with higher recycling gain increased this coherence to 0.35.

There is clear correlation where the alignment with higher recycling gain has a higher jitter coupling. There also seems to be some thermal effect where the interferometer initially has a lower coupling.

The calibration of the DBB QPD jitter is just the inverse of the sum divided by 60 to account for the PMC transmission. The jitter measured by the IMC WFS DC was scaled by 1/3 to match the measurement when the IMC was unlocked.

Looking at the comparison of jitter during O1 and now (alog 30581) as measured by the IMC WFS DC, one might expect that the HPO jitter can explain all excess low frequency jitter below 70 Hz. This seems to work fine for pitch, but not very well for yaw. The coherence between WFS B DC yaw with the DBB QPD channels isn't higher than 0.3.

The effect of the alignment change on the DARM jitter coupling makes one wonder, if there isn't a Gouy phase conspiracy, where the coupling of the periscope peak is mostly independent. The Gouy phase difference between the periscope peak and the HPO jitter seems to be roughly 120°, if we believe the WFS DC readbacks. MC_F and REFL_SERVO_CTRL mainly see jitter peaks after the PMC. The auxiliary length dofs don't see much more than the periscope peak itself. Only DARM seems to be sensitive to the HPO jitter.

Non-image files attached to this report
H1 General
cheryl.vorvick@LIGO.ORG - posted 17:03, Friday 18 November 2016 (31630)
Ops Eve Transition: relocked and a2l in DC readout and NLN

State of H1: in DC readout, measured a2l, NLN, measured a2l

Activities:

LHO VE
chandra.romel@LIGO.ORG - posted 16:34, Friday 18 November 2016 (31624)
CP3 overfill
4:10pm local

Took 2 min. to overfill from control room by increasing LLCV from 16% to 50%. I raised nominal to 17% for weekend.
Images attached to this report
H1 ISC
cheryl.vorvick@LIGO.ORG - posted 16:33, Friday 18 November 2016 - last comment - 16:36, Friday 18 November 2016(31625)
running a2l script in DC readout - 00:30UTC

Comments related to this report
cheryl.vorvick@LIGO.ORG - 16:35, Friday 18 November 2016 (31626)

first attempt stoped for file edit: 0:35UTC

cheryl.vorvick@LIGO.ORG - 16:36, Friday 18 November 2016 (31627)

running a2l, started at 00:36UTC

H1 SEI
hugh.radkins@LIGO.ORG - posted 16:30, Friday 18 November 2016 (31623)
Some DIffs on ITMY ISI SDF--let em ride.

Jim is doing some testing/studies on the tilt ISO dofs.  Please let these 10 diffs remain for now.  Be mindful of other changes of course but none should come up.

Images attached to this report
H1 SEI (ISC)
hugh.radkins@LIGO.ORG - posted 16:12, Friday 18 November 2016 (31622)
29 hour lock stretch--look ma: tides!

Attached are the ISC relief to HEPI; units are nanometers.  Finally, a complete tide cycle!  If only we had the iLigo predictor running.

Looks like we had plenty of head room on HEPI but it is interesting that the Yarm never went negative like the Xarm.  Not sure that means much at a day plus stretch.  Maybe some initial grab residual.  I expect it would start behaving after a few days lock

Images attached to this report
LHO General
thomas.shaffer@LIGO.ORG - posted 16:05, Friday 18 November 2016 (31585)
Ops Day Shift Summary

TITLE: 11/19 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Cheryl
SHIFT SUMMARY: 26.6hr Lock ended 30min before the end of my shift. While it was locked we ran a2L a few times and Commissioners did some work when they could.
LOG:

H1 CAL (CSWG, DetChar, ISC, SUS)
jeffrey.kissel@LIGO.ORG - posted 15:11, Friday 18 November 2016 - last comment - 16:22, Wednesday 05 July 2017(31603)
H1 SUS ETMY High-Frequency Actuation UIM/L1
J. Kissel, D. Tuyenbayev

Analyzing the high-frequency data for the UIM that we took last night (LHO aLOG 31601), we find -- as previously suspected -- there is lots of dynamical resonant features in the UIM / L1 actuation stage; it definitely does NOT fall as f^6 to infinity as one might naively suspect. 

There are even more features than the (now anticipated; LHO aLOG 31432) broad impacts of the violin modes of the Sus Point-to-TOP wires (~311 Hz), and UIM-to-PUM wires (~420 Hz). We had seen hints of these features previously (LHO aLOG 24917), but here they are fully characterized out to 500 Hz with a combination of swept-sine (SS) and broad-band (BB) transfer function ratios (the calibration standard measurements of PCAL2DARM = C / (1+G) and iEXC2DARM = C A_i / (1+G)). The measurements yield the actuation strength of the UIM stage, in terms [m] of test mass displacement per [ct] of drive from the L1_TEST_L bank, which is the Euler-basis equivalent to DAC [ct]. To scale to [m/N], is a mere scale factor, measured to be 
     20/2^18 [V/ct] 0.62e-3 [A/V]* 1.7082 [N/A] = 8.08e-8 [N/ct] (see LHO aLOG 31344).


Via private communication in January this year, Norna suspects that 111 Hz feature is the first internal mode of the UIM blades, backed by a bench test of the blades at CIT which revealed a resonance at 109 Hz. No ideas on the 167 Hz mode though.

These high frequency dynamics continue to plague the estimate of the UIM actuation strength at DC using the traditional frequency-dependent sweep method, because these high frequency dynamics begin to affect the actuation strength at as low a frequency as ~30 Hz (LHO aLOG 31427), and any model fitting code gets totally distracted by these features. 

A challenge to the CSWG team: fit this transfer function above 20 Hz and create a set of zeros and poles that can be used as a "correction" filter to a model that falls off as f^6. This filter need not perfectly resolve the details of all of the high-Q features, but it must track the overall frequency dependence over the 20 - 500 Hz region well. I attach all of the measurements compressed onto one (discontinuous) frequency vector as an ascii in the standard DTT form of [freq re(TF) im(TF)]. To use: 
    >> foo = load('2016-11-17_H1SUSETMY_L1_Actuation_HighFreqChar_asciidump.txt')
    >> figure; loglog(foo(:,1), abs( foo(:,2)+1i*foo(:,3) ))
This data is also committed to the CalSVN repo here:
    /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/Results/Actuation/2016-11-17_H1SUSETMY_L1_Actuation_HighFreqChar_asciidump.txt
Kiwamu has already tried to create such a filter from the previous data (LHO aLOG 28206), but was limited by  that measurement's high-frequency bound falling between the 111, 137, and 167 Hz features. 

Details:

Analysis code:
    /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/Scripts/FullIFOActuatorTFs/process_H1SUSETMY_L1_HFDynamicsTest_20161117.m

Config files:
    IFOindepPars = '../../../Common/params/IFOindepParams.conf';
    IFOdepPars   = {'../../params/H1params.conf'};
    IFOmeasPars  = {'../../params/2016-11-12/H1params_2016-11-12.conf'};
    PCALPars = {'../../params/2016-11-12/measurements_2016-11-12_ETMY_L1_actuator.conf'};

Model:
    /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/DARMmodel/src/computeDARM.m

Will post the data for the fitting challenge later this afternoon.
Images attached to this report
Non-image files attached to this report
Comments related to this report
brett.shapiro@LIGO.ORG - 19:42, Saturday 19 November 2016 (31656)DetChar, ISC, SUS

I made an update to the quad matlab model to account for these mystery features. See CSWG log 11197.

dennis.coyne@LIGO.ORG - 23:13, Wednesday 08 March 2017 (34688)

I describe my use of the Frequency Domain System Identification toolbox (FDIDENT) to fit this transfer function in CSWG elog #11205. FDIDENT is a third party Matlab toolbox which provides tools for identifying linear dynamic single-input/single-output (SISO) systems from time response or frequency response measurements. The toolbox is free for non-profit use.

https://www.mathworks.com/products/connections/product_detail/product_35570.html

http://home.mit.bme.hu/~kollar/fdident/

A stable, but non-minimum phase, model without delay – compatible with a Linear Time Invariant (LTI) representation -- results in a best fit for a 22 order numerator and 28 order denominator model, m2228. The model is compared to the measurement data in the attached bode plot.

Images attached to this comment
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 16:22, Wednesday 05 July 2017 (37338)
I attach several new parts of this high frequency characterization in order to facilitate incorporating the uncertainty in any future transfer function fitting. 

I attach three new text files:
    "..._tf.txt" -- a copy of the originally attached text file, columns are 
        [freq re(A) im(A)]
    "..._coh.txt" -- an export of the (prefiltered) coherence, columns are 
        [freq iEXCCoh PCALCoh]
    "..._relunc.txt" -- an export of the combined relative uncertainty on the transfer function, columns are 
        [freq sigma_A]

Computing the uncertainty on this actuation strength was a bit of a challenge. 
Remember, the above measure of the actuation strength of the UIM stage, A, is a combination of two transfer functions, as described in P1500248, Section V. In this aLOG they're referred to as "PCAL2DARM" where we use the photon calibrator as a reference actuator, and "iEXC2DARM" where the suspension stage under test is used as the actuator. Typically, the iEXC2DARM transfer function has the lowest coherence. 
Even worse, I've combined many data sets of both transfer functions covering different frequency regions each with a different number of averages.
Thus form the uncertainty, I've taken each frequency region's data set, and 
    - Filtered both iEXC and PCAL transfer functions for data points in which the iEXC TF has coherence greater than 0.95,
    - Created a relative uncertainty vector for each iEXC and PCAL transfer functions using the standard B&P equation,
        sigma_TF(f) / TF = sqrt( (1-C(f)) / (2 N C(f)) )
    where C(f) is the coherence, and N is the number of averages (N was 10 for swept sine TFs, 25 for broad band TFs)
    - Concatenated the data sets to form the overall transfer function, A,
    - Combined the two uncertainty vectors in the standard way,
        sigma_A / A = sqrt((sigma_iEXC / iEXC)^2 + (sigma_PCAL / PCAL)^2)
    - Sorted the collection of 
        [frequency complextf iexccoh pcalcoh sigma_A]
    by frequency.
    - Exported the uncertainty.

Note that one only needs one column of uncertainty, for the absolute uncertainty in magnitude is just
    |sigma_A| = abs(A) * (sigma_A / A)
and the absolute uncertainty in phase is
    /_ sigma  = 180/pi * (sigma_A / A)

I attach a plot of the magnitude and its uncertainty for demonstrative purposes, so that when the files are used, you can compare your plots of this against mine to be sure you're using the data right. Note that I've multiplied the uncertainty by a factor of 10 for plotting only so that it's visible.

I've updated and committed the function that's used to process this data, and it can be found here:
    /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/Scripts/FullIFOActuatorTFs/
    process_H1SUSETMY_L1_HFDynamicsTest_20161117.m
Images attached to this comment
Non-image files attached to this comment
H1 CAL (DetChar)
jeffrey.kissel@LIGO.ORG - posted 13:43, Friday 18 November 2016 - last comment - 15:33, Friday 18 November 2016(31610)
1083.7 Hz CAL Line Turned OFF Temporarily
J. Kissel

There's been renewed excitement about the relationship between the 1083.7 Hz calibration line and the surrounding, non-stationary PSL intensity/jitter noise coupling into the sensitivity. Namely, DetChar has seen glitching "around the 1 kHz calibration line." I had looked at this relationship briefly a few moons ago (see LHO aLOG 31035) and concluded these features were unrelated, and did not impact the use of the 1083.7 Hz line due to the intensity/jitter noise's convenient double-peak shape.  

I had thought I'd run an on/off test during that study, but rather than dig up the history, I find it easier to just run a new on/off test.

As such, I've turned OFF the 1083.7 Hz calibration line at Nov 18 2016 21:33:40 UTC, Nov 18 2016 13:33:40 PST, GPS 1163540037.

If we survive the EQ that's now hitting as I type this aLOG, I'll leave it OFF for an hour or two.
Images attached to this report
Comments related to this report
beverly.berger@LIGO.ORG - 14:06, Friday 18 November 2016 (31612)DetChar

The attached plot shows that the noisy behavior around the frequency of this line persists after it was turned off.

Images attached to this comment
jeffrey.kissel@LIGO.ORG - 15:33, Friday 18 November 2016 (31617)DetChar
1083.7 Hz calibration line restored just after the lock loss at 2016-11-18 23:30 UTC.
LHO VE
chandra.romel@LIGO.ORG - posted 10:34, Friday 18 November 2016 - last comment - 16:39, Friday 18 November 2016(31597)
RGA filaments ON
WP 6328

This morning we turned ON filaments of RGAs at EY and corner......from the control room! Gerardo will set the IP address for EX to complete WP. 

I was disappointed to find that we cannot connect to multiple devices at one time to monitor multiple scans in RGA software. Contacted vendor about this. Analog signal monitoring via CDS will help (ECR 1600307).
Comments related to this report
chandra.romel@LIGO.ORG - 16:39, Friday 18 November 2016 (31629)
We just needed the multiplexer software key so now we are connected to multiple RGA devices!
H1 SUS
hugh.radkins@LIGO.ORG - posted 10:26, Friday 18 November 2016 - last comment - 15:59, Friday 18 November 2016(31595)
Added L2_DRIVEALIGN_L2P_GAIN to OBSERVE.snap Not Monitored list for TMs

JeffK & HughR

This is to be ready for changes resulting from the A2L running on a regular basis.  While at it I snapped a view of the TMs L2 Drive Align L2P filter banks.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 11:17, Friday 18 November 2016 (31604)

These channels should probably be re-monitored.  You've unmonitored the L2Ps, when it's actually the P2Ls (and Y2Ls) that will change when we run A2L.  The P2L and Y2L gains are already not monitored for all the test masses.  I have re-monitored the L2P gains.

hugh.radkins@LIGO.ORG - 15:59, Friday 18 November 2016 (31620)

Doh! Smackforehead.

H1 OpsInfo
terra.hardwick@LIGO.ORG - posted 10:10, Friday 18 November 2016 - last comment - 15:45, Friday 18 November 2016(31593)
Op requests whenever we relock

Whoever is in the chair next when we have to relock (days from now I'm sure...), please:

Thanks a bunch - the past few days of everyone helping play this long timescale PI game has been super helpful. 

Comments related to this report
edmond.merilh@LIGO.ORG - 10:23, Friday 18 November 2016 (31594)

When you say a2l, do you mean the trio of them or just the one original, main one?

terra.hardwick@LIGO.ORG - 10:32, Friday 18 November 2016 (31596)

Ya just the main one: a2l_min_LHO. Thanks Ed.

sheila.dwyer@LIGO.ORG - 15:45, Friday 18 November 2016 (31619)

General comment for operators:

when you run a2l make sure you take the observatory mode to commisioning first, then you can put it back when the script finishes.  This way we can avoid confusing people.  Once we have SDF tied into the intention bit this would automatically drop us out of observing. 

H1 CAL (CAL, DetChar)
jeffrey.kissel@LIGO.ORG - posted 09:16, Friday 18 November 2016 - last comment - 15:33, Friday 18 November 2016(31589)
PCALX Roaming Calibration Line Frequency Changed from 4301.3 to 4501.3 Hz
Beautifully high duty cycle over the past few says. Nice work team! 

Current Schedule Status:
Frequency    Planned Amplitude        Planned Duration      Actual Amplitude    Start Time                 Stop Time                    Achieved Duration
(Hz)         (ct)                     (hh:mm)                   (ct)               (UTC)                    (UTC)                         (hh:mm)
---------------------------------------------------------------------------------------------------------------------------------------------------------
1001.3       35k                      02:00                   39322.0           Nov 11 2016 21:37:50 UTC    Nov 12 2016 03:28:21 UTC      ~several hours @ 25 W
1501.3       35k                      02:00                   39322.0           Oct 24 2016 15:26:57 UTC    Oct 31 2016 15:44:29 UTC      ~week @ 25 W
2001.3       35k                      02:00                   39322.0           Oct 17 2016 21:22:03 UTC    Oct 24 2016 15:26:57 UTC      several days (at both 50W and 25 W)
2501.3       35k                      05:00                   39322.0           Oct 12 2016 03:20:41 UTC    Oct 17 2016 21:22:03 UTC      days     @ 50 W
3001.3       35k                      05:00                   39322.0           Oct 06 2016 18:39:26 UTC    Oct 12 2016 03:20:41 UTC      days     @ 50 W
3501.3       35k                      05:00                   39322.0           Jul 06 2016 18:56:13 UTC    Oct 06 2016 18:39:26 UTC      months   @ 50 W
4001.3       40k                      10:00                   39322.0           Nov 12 2016 03:28:21 UTC    Nov 16 2016 22:17:29 UTC      days     @ 30 W (see LHO aLOG 31546)
4301.3       40k                      10:00                   39322.0           Nov 16 2016 22:17:29 UTC    Nov 18 2016 17:08:49 UTC      days     @ 30 W            
4501.3       40k                      10:00                   39322.0           Nov 18 2016 17:08:49 UTC                
4801.3       40k                      10:00  
5001.3       40k                      10:00
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 13:44, Friday 18 November 2016 (31611)DetChar
The 1083.7 Hz calibration line was turned OFF for a brief period (~1-2 hours) during this current 4501.3 Hz stretch. See LHO aLOG 31610 for details.
jeffrey.kissel@LIGO.ORG - 15:33, Friday 18 November 2016 (31618)
1083.7 Hz calibration line restored just after the lock loss at 2016-11-18 23:30 UTC.
H1 ISC
hugh.radkins@LIGO.ORG - posted 09:12, Friday 18 November 2016 - last comment - 16:01, Friday 18 November 2016(31588)
High Precision ASC & LSC Round off changes saved in OBSERVE.snaps

First attachment is the ASC changes accepted.  All the ones accepted are gains that have been rounded off to 4 places rather than 10.  I did miss one matrix value (circled) but I've corrected that in the file directly and reloaded that to the FE.  The 23 remaining differences are filters, offsets and matrix changes requiring more scrutiny.

For the LSC, the same applies.  There is one offset difference remaining--see attached.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 11:23, Friday 18 November 2016 (31605)

The one channel remaining in the LSC SDF was H1:PSL-POWER_SCALE_OFFSET, which is changed by the LASER_PWR guardian as it changes the PSL power into the vacuum.  This will be different every lock, so I have un-monitored it in the Observe.snap file.  Also, TJ has changed the guardian to round it to 4 decimal places, which is more than plenty of precision.

jenne.driggers@LIGO.ORG - 11:46, Friday 18 November 2016 (31608)

Looking right now, everything left in the ASC SDF is stuff that is actively being worked on (SOFT offsets, input matrix for PRC2, etc), so we don't know yet what we'll run with for O2.  These should all stay monitored.

All of the filters in the DC loops were notches that were turned on for a sensing matrix measurement, and should have been turned off.  When I turned the notches off, the diffs went away, so we already had the correct settings accepted.

hugh.radkins@LIGO.ORG - 16:01, Friday 18 November 2016 (31621)

Thanks for the fine-tuning and details--just what we need for good control--Thanks Jenne--H