Displaying reports 58941-58960 of 89678.Go to page Start 2944 2945 2946 2947 2948 2949 2950 2951 2952 End
Reports until 10:34, Friday 18 November 2016
LHO VE
chandra.romel@LIGO.ORG - posted 10:34, Friday 18 November 2016 - last comment - 16:39, Friday 18 November 2016(31597)
RGA filaments ON
WP 6328

This morning we turned ON filaments of RGAs at EY and corner......from the control room! Gerardo will set the IP address for EX to complete WP. 

I was disappointed to find that we cannot connect to multiple devices at one time to monitor multiple scans in RGA software. Contacted vendor about this. Analog signal monitoring via CDS will help (ECR 1600307).
Comments related to this report
chandra.romel@LIGO.ORG - 16:39, Friday 18 November 2016 (31629)
We just needed the multiplexer software key so now we are connected to multiple RGA devices!
H1 SUS
hugh.radkins@LIGO.ORG - posted 10:26, Friday 18 November 2016 - last comment - 15:59, Friday 18 November 2016(31595)
Added L2_DRIVEALIGN_L2P_GAIN to OBSERVE.snap Not Monitored list for TMs

JeffK & HughR

This is to be ready for changes resulting from the A2L running on a regular basis.  While at it I snapped a view of the TMs L2 Drive Align L2P filter banks.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 11:17, Friday 18 November 2016 (31604)

These channels should probably be re-monitored.  You've unmonitored the L2Ps, when it's actually the P2Ls (and Y2Ls) that will change when we run A2L.  The P2L and Y2L gains are already not monitored for all the test masses.  I have re-monitored the L2P gains.

hugh.radkins@LIGO.ORG - 15:59, Friday 18 November 2016 (31620)

Doh! Smackforehead.

H1 OpsInfo
terra.hardwick@LIGO.ORG - posted 10:10, Friday 18 November 2016 - last comment - 15:45, Friday 18 November 2016(31593)
Op requests whenever we relock

Whoever is in the chair next when we have to relock (days from now I'm sure...), please:

Thanks a bunch - the past few days of everyone helping play this long timescale PI game has been super helpful. 

Comments related to this report
edmond.merilh@LIGO.ORG - 10:23, Friday 18 November 2016 (31594)

When you say a2l, do you mean the trio of them or just the one original, main one?

terra.hardwick@LIGO.ORG - 10:32, Friday 18 November 2016 (31596)

Ya just the main one: a2l_min_LHO. Thanks Ed.

sheila.dwyer@LIGO.ORG - 15:45, Friday 18 November 2016 (31619)

General comment for operators:

when you run a2l make sure you take the observatory mode to commisioning first, then you can put it back when the script finishes.  This way we can avoid confusing people.  Once we have SDF tied into the intention bit this would automatically drop us out of observing. 

H1 ISC
hugh.radkins@LIGO.ORG - posted 09:57, Friday 18 November 2016 - last comment - 11:36, Friday 18 November 2016(31591)
Channels added to the LSC not monitored list

Many of the gain changes I just accepted into the LSC OBSERVE.snap are showing as differences in the safe.snap.  With conference of JeffK, we are pretty positive these are values changed by Guardian.  So, I am adding these values to the safe.snap Not Monitored list--see attached.  They are ASAIR, POPAIR, POP, REFLAIR, & REFL: A & B, RF18/90/9/45, I & Q gains.  18 total channels.  This makes 125 not monitored channels yet with these additions, there are only 62 differences for all setpoints.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 11:36, Friday 18 November 2016 (31606)

I think these should be re-monitored in the safe.snap file.  These values (the ones that are the setpoints in the safe.snap screenshot) are written in the ISC_LOCK DOWN state.  If they are not correct, we may have trouble locking.  They are then changed by guardian to the values in the Observe.snap screenshot when we reduce the modulation depths of the 9 and 45 MHz.  So, the values that we want will be different in the safe and observe snap files, but we probably want to be monitoring them in both.

Actually, rethinking on it, Hugh's not-monitoring of these channels in the safe.snap file is totally consistent with everything we've been doing lately (not-monitoring channels that are written explicitly by guardian).  Whether our current strategy makes any sense is a larger conversation, but these channels are probably fine not being monitored.

H1 PEM (OpsInfo, SYS)
richard.mccarthy@LIGO.ORG - posted 09:41, Friday 18 November 2016 - last comment - 10:07, Friday 18 November 2016(31590)
End X VEA temperature
Raised the Heater setpoint from 8ma to 9ma.  We had approximately a 1/2 deg F drop in temperature in the VEA last night.  
Also raised AHU-3 heaters from 3ma to 5ma to turn one stage on.
Comments related to this report
john.worden@LIGO.ORG - 10:07, Friday 18 November 2016 (31592)

I noticed that the LVEA dipped a little yesterday morning so I increased 1A, 1B, 4, 5 all by 0.5 ma to 8.0 ma.

H1 CAL (CAL, DetChar)
jeffrey.kissel@LIGO.ORG - posted 09:16, Friday 18 November 2016 - last comment - 15:33, Friday 18 November 2016(31589)
PCALX Roaming Calibration Line Frequency Changed from 4301.3 to 4501.3 Hz
Beautifully high duty cycle over the past few says. Nice work team! 

Current Schedule Status:
Frequency    Planned Amplitude        Planned Duration      Actual Amplitude    Start Time                 Stop Time                    Achieved Duration
(Hz)         (ct)                     (hh:mm)                   (ct)               (UTC)                    (UTC)                         (hh:mm)
---------------------------------------------------------------------------------------------------------------------------------------------------------
1001.3       35k                      02:00                   39322.0           Nov 11 2016 21:37:50 UTC    Nov 12 2016 03:28:21 UTC      ~several hours @ 25 W
1501.3       35k                      02:00                   39322.0           Oct 24 2016 15:26:57 UTC    Oct 31 2016 15:44:29 UTC      ~week @ 25 W
2001.3       35k                      02:00                   39322.0           Oct 17 2016 21:22:03 UTC    Oct 24 2016 15:26:57 UTC      several days (at both 50W and 25 W)
2501.3       35k                      05:00                   39322.0           Oct 12 2016 03:20:41 UTC    Oct 17 2016 21:22:03 UTC      days     @ 50 W
3001.3       35k                      05:00                   39322.0           Oct 06 2016 18:39:26 UTC    Oct 12 2016 03:20:41 UTC      days     @ 50 W
3501.3       35k                      05:00                   39322.0           Jul 06 2016 18:56:13 UTC    Oct 06 2016 18:39:26 UTC      months   @ 50 W
4001.3       40k                      10:00                   39322.0           Nov 12 2016 03:28:21 UTC    Nov 16 2016 22:17:29 UTC      days     @ 30 W (see LHO aLOG 31546)
4301.3       40k                      10:00                   39322.0           Nov 16 2016 22:17:29 UTC    Nov 18 2016 17:08:49 UTC      days     @ 30 W            
4501.3       40k                      10:00                   39322.0           Nov 18 2016 17:08:49 UTC                
4801.3       40k                      10:00  
5001.3       40k                      10:00
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 13:44, Friday 18 November 2016 (31611)DetChar
The 1083.7 Hz calibration line was turned OFF for a brief period (~1-2 hours) during this current 4501.3 Hz stretch. See LHO aLOG 31610 for details.
jeffrey.kissel@LIGO.ORG - 15:33, Friday 18 November 2016 (31618)
1083.7 Hz calibration line restored just after the lock loss at 2016-11-18 23:30 UTC.
H1 ISC
hugh.radkins@LIGO.ORG - posted 09:12, Friday 18 November 2016 - last comment - 16:01, Friday 18 November 2016(31588)
High Precision ASC & LSC Round off changes saved in OBSERVE.snaps

First attachment is the ASC changes accepted.  All the ones accepted are gains that have been rounded off to 4 places rather than 10.  I did miss one matrix value (circled) but I've corrected that in the file directly and reloaded that to the FE.  The 23 remaining differences are filters, offsets and matrix changes requiring more scrutiny.

For the LSC, the same applies.  There is one offset difference remaining--see attached.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 11:23, Friday 18 November 2016 (31605)

The one channel remaining in the LSC SDF was H1:PSL-POWER_SCALE_OFFSET, which is changed by the LASER_PWR guardian as it changes the PSL power into the vacuum.  This will be different every lock, so I have un-monitored it in the Observe.snap file.  Also, TJ has changed the guardian to round it to 4 decimal places, which is more than plenty of precision.

jenne.driggers@LIGO.ORG - 11:46, Friday 18 November 2016 (31608)

Looking right now, everything left in the ASC SDF is stuff that is actively being worked on (SOFT offsets, input matrix for PRC2, etc), so we don't know yet what we'll run with for O2.  These should all stay monitored.

All of the filters in the DC loops were notches that were turned on for a sensing matrix measurement, and should have been turned off.  When I turned the notches off, the diffs went away, so we already had the correct settings accepted.

hugh.radkins@LIGO.ORG - 16:01, Friday 18 November 2016 (31621)

Thanks for the fine-tuning and details--just what we need for good control--Thanks Jenne--H

LHO General
thomas.shaffer@LIGO.ORG - posted 08:46, Friday 18 November 2016 (31587)
Morning Meeting Minutes

SEI - All good.

SUS - All good.

ISC - Sheila and Nutsinee were moving PR3 last night to increase optical gain. Pop beam diverters are still open due to REFL WFS trouble.

CDS - HW - Running, anemometers are all up except at EY. Heading to the vault today.

         - SW - Stable. Working on installing Debian8 on various work stations. Seems sucessful so far. Impressed enough that they may want to replace everything with it, please be giving them feedback.

PSL - Still running. TCS as well.

Vac - Today Chandra would like ot tune the filaments on the RGAs, can be done from the CR. Looking for partial pressure changes in locklosses.

Fac - If you find something broken, please just call the appropriate person rather than emailing because they may not get to the email in a timely manner.

Cal - Got the last set of measurements last night, about ready to update the calibration.

Reviewed Fault reports

Robert and Annamaria will be coming to do PEM injections next week.

if you see cds macbooks 3 & 7, please bring them back to Carlos or Jim B.

H1 General
nutsinee.kijbunchoo@LIGO.ORG - posted 08:13, Friday 18 November 2016 (31584)
Ops OWL shift summary

TITLE: 11/18 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC

STATE of H1: Observing at 66.2053Mpc

INCOMING OPERATOR: TJ

SHIFT SUMMARY: Locked for 22 hours and counting. 

LOG:

07:50 Started ITMX HWS script (left it off to test some other script on Wednesday and forgot to run it)

08:01 Increased violin mode damping gain for ETMY 508.585

08:08 Chaged CO2Y power upper limit so the ODC bit is green. Accepted the change in SDF.

12:43 LLO lost lock. Took IFO out of Observing so I can do some PRM test for Sheila. Here's what happened:

13:36 LLO back to Observe. Slowly revert PRM gain and took some DARM spectrum in the process.

13:51 Back to Observing

~15:20 Joe moved a ladder from Mid of sec1 Y beamtube to Y12.

15:10-15:15 Weird noise in AS90/POP90 (see attachment). I was looking at Sheila's Build_ups striptool and only POPAIR_B_RF90 seems to see this.

Images attached to this report
H1 ISC
terra.hardwick@LIGO.ORG - posted 05:22, Friday 18 November 2016 - last comment - 11:05, Friday 18 November 2016(31583)
Mode Temperature Dependence cont.

Aidan, Terra

A continuation of alog 30522

Previously we'd found that frequency drift over a lock stretch is mode dependent - differential drumhead mode drifts more than that same optic's drumhead mode - but surmised that the ratio of (change of frequency / frequency) between two modes would be constant. However, this assumed a spacially uniform change in temperature --- fm = g(T) --- when a more realistic assumption is some radial dependence of T, so: 

fm = g(T(r)), where r is radial vector

Since the energy distribution of a given mode is also dependent on r, we can expect some modally unique self heating response. In other words, the more overlap between a given mechanical mode and the hot spots of the optic, the larger the frequency drift we'd expect that mode to have. 

I've looked at ETMY 15009 Hz diff drumhead mode shift compared with ETMY 8158 Hz drumhead shift during twelve hours of a recent lock. 15009 Hz relative frequency change is larger than drumhead relative change and the ratio begins to level off towards a constant after about six hours. We expect (and model) the opposite - the drumhead mode would have more thermal overlap and thus would shift more. This assumes a mostly centered beam spot (or equivalently, assumes r = 0 at the center of the optic). Looking at Jenne's recent beam spot investigation, ETMY spot position was fairly centered during this time, off in yaw by a few mm. The 15009 Hz mode is differential in pitch. (I still suspect some dependence on torsional vs. longitudinal mode movement as suggested in alog 30522.)

We've started having operators run a2l more regularly and before and after powerup at times to get assurance of beam spot position. 

Images attached to this report
Comments related to this report
terra.hardwick@LIGO.ORG - 11:05, Friday 18 November 2016 (31600)

Quick look at the frequency drift for ETMY 15009 Hz and Drumhead during the first 12 hours of the current lock. Ignore the giant vertical line of glitch terribleness. Also I tried fitting the Drumhead df/f with a sum of weighted exponentials (though note that tau == b is the same for each series element) as a very preliminary comparison with thermal lens response to power step. 

Images attached to this comment
H1 General
nutsinee.kijbunchoo@LIGO.ORG - posted 02:43, Friday 18 November 2016 (31582)
(Late) Ops OWL shift Transition

TITLE: 11/18 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC

STATE of H1: OBSERVING
OUTGOING OPERATOR: Corey
QUICK SUMMARY: H1 has been locked 16 hours and counting. Sheila sent me an instruction and asked me to play with PRM. I'm waiting for LLO to be out of Observing before doing that. If that doesn't happen I will do it towards the end of shift.

H1 ISC
terra.hardwick@LIGO.ORG - posted 02:29, Friday 18 November 2016 - last comment - 11:14, Friday 18 November 2016(31577)
32 W PI modes update

After getting wack values for PI mode ring ups (many orders of magnitude off from expected) earlier in the week, I've refit ring ups and taken new ones and gotten much more reasonable values (I wasn't looking at long enough time stretches to get accurate ring up data before). Note that we haven't had any instability in Mode3 in many days so I haven't been able to remeasure it. 

Mode # Freq Optic tau Q
3 15606 Hz ITMX TBD TBD
26 15009 Hz ETMY 316 s 15 M
27 47495 Hz ETMY 92 s 5 M
28 47477 Hz ETMY 89 s 5.2 M

Mode 3 hasn't been unstable in many days and Modes 27 & 28 are only unstable during the initial ~ 1-2 hours of transient. Attached are two 30 hour stretches of the damping output of the three modes during recent long locks (Mode3 had no output so I left off) and the simulated HOOM spacing to get an idea of when the modes are ringing up enough to engage damping loops. Left is a few days ago and right is the current lock. Note that Mode26 looks continuously unstable during the 11/16 lock, but it could be that the damping gain is triggering below an actual unstable amplitude; compare to the current lock where we set the gain for Mode26 to zero just after 19:30 (so there would be no damping output) but it has remained stable and low since then with no need to damp. 

Operators and myself are currently turning off gain and measuring ring ups during different times of lock stretches to get gains at different stages of the thermal transient. 

Images attached to this report
Comments related to this report
terra.hardwick@LIGO.ORG - 11:14, Friday 18 November 2016 (31602)

Current damping status of this now > 25 hour 32 W lock: no damping required after the first 2 hours. Attached plots again show damping loop output over the past 26 hours and HOOM spacing for reference. 

Images attached to this comment
LHO General
corey.gray@LIGO.ORG - posted 00:05, Friday 18 November 2016 (31576)
OPS Eve Shift Summary

TITLE: 11/18 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Commissioning
INCOMING OPERATOR: Nutsinee
SHIFT SUMMARY:
Did not get to ANY of my ToDoList!  Because H1 has been locked the whole shift (going on 14hrs).  So I passed these items on to Nutsinee.  Nutsinee did notice big Violin Modes.  I talked to the LLO Operator to check their status (Robert still doing PEM injections), so Nutsinee will try to damp the violins (because if they get rung up more it will make locking difficult.).  LLO will contact us when they go to OBSERVING.

LOG:

To Do:

H1 SEI (ISC)
hugh.radkins@LIGO.ORG - posted 16:25, Thursday 17 November 2016 - last comment - 23:03, Thursday 17 November 2016(31573)
ETMY ISI Tripped after LockLoss this monring--TIDAL RED TRIGGER lag

With full lock, the H1:LSC-Y_TIDAL_REDTRIG_INMON has a value of 175000.  The H1:LSC-Y_TIDAL_REDTRIG_THRESH_OFF had a value of 10 and it takes almost 4 seconds to reach that threshold.  Meanwhile, the ISC was still driving HEPI and does so quickly causing the ISI T240s to be driven to trip.

In the attached 10 seconds trend, the lock loss is clear with the ASC TR SUM dropping along with the REDTRIG power.  The signal finally reaches 10 almost 4 seconds later seen on the TIDAL_CMD trace.  Meanwhile, ISC has rapidly driven HEPI >100um, quite quickly.  By then the T240s are too far gone (Red Trace #1) and will trip the WD.

Sheila & Daniel have increased the ON/OFF thresholds to 8000/5000.  This should work for 2 watt lock and reduce our delay to under two seconds--maybe enough.  But why is this suddenly a problem?  Or is it some series of unfortunate events that made it happen this time?  Scaling the thresholds with power is the better albeit complex solution.

Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 23:03, Thursday 17 November 2016 (31580)

Not all lock losses are the same. Some will loose power fast (thru the AS port) while other are much slower (REFL port).

H1 ISC
daniel.sigg@LIGO.ORG - posted 17:14, Wednesday 16 November 2016 - last comment - 10:42, Friday 18 November 2016(31554)
Frequency Noise Spectra

The attached plots show the frequency noise seen by the reference cavity (green), the IMC (red), the REFL port (blue)  and the POP port (brown). The first plot also shows the estimated in-loop suppressed noise in a lighter color as well.

The second plot shows uncalibrated traces but with a 30 kHz bandwidth. The peaks at ~7250 Hz and at ~13.6 kHz are already present in the IMC spectra when the interferometer is unlocked, and, therefore, are not introduced by the REFL servo. The I' channels are the DAQ sensor channels closest to true in-phase signals.

Non-image files attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 10:42, Friday 18 November 2016 (31598)

A few notes to the calibrations:

  • The reference cavity calibration is based on the PZT sensitivity of the Innolight laser. It will be good up to the FSS crossover.
  • The in-loop curve is based on an FSS servo model which assumes a nominal ugf, but with a crossover a factor of 2 low. This in turn produces gain peaking around 2 kHz which is required to explain the coherence with MC_F.
  • The MC_F calibration is based on the VCO calibration.
  • The in-loop curve is derived from an IMC length model with an ugf of 64 kHz.
  • The LSC REFL calibration is based on alog 30549. It agrees with the IMC model and the VCO calibration.
  • The in-loop curve is derived from a interferometer REFL model with a ugf around 20 kHz.
  • The PRC calibration is based on a simple scaling so that it agrees with in-loop REFL at 7 kHz. This is motivated by a coherence of 100% at this frequency.
H1 OpsInfo (OpsInfo)
jim.warner@LIGO.ORG - posted 13:30, Wednesday 16 November 2016 - last comment - 02:36, Friday 18 November 2016(31543)
FAMIS Weeklies tab added to Sitemap

I've added a Weeklies screen to the Sitemap to make it easier for the operators to do FAMIS tasks. It can be found under the OPS tab. Pretty simple, there are a number of buttons that launch different scripts for different FAMIS tasks, so operators don't have to navigate from the command line. Operators and detector engineers should feel free to add tasks to this screen, I added the ones I could think of. Hopefully we can rely on this screen to make sure that operators use 1 version of a script, and give cognizant engineers some control over which version is used.

I also encourage anyone with any artistic inclinations to make it look nicer. I got nothin'.

Images attached to this report
Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 02:36, Friday 18 November 2016 (31581)

I gave the medm screen some colors. Blue indicates seismic related tasks, oplev gets red, and PSL gets purple. I can always organize them better if the number of tasks grow.

Images attached to this comment
H1 OpsInfo
edmond.merilh@LIGO.ORG - posted 17:25, Thursday 03 November 2016 - last comment - 08:41, Friday 18 November 2016(31182)
Running a2l scriptS now

There are now THREE a2l scripts that we will be running once during EACH lockstretch. Patrick mentioned them in his time log. I'm tagging Opsinfo with the information again.

cd /opt/rtcds/userapps/release/isc/common/scripts/decoup

./a2l_min_LHO.py

./a2l_min_PR2.py

./a2l_min_PR3.py

that is all :)

Comments related to this report
corey.gray@LIGO.ORG - 10:34, Monday 07 November 2016 (31280)

A note on the (3) A2L measurements.  

  1. The ...LHO.py file can improve H1 performance.
  2. The ...PR2 & PR3.py files are for data-taking purposes (Jenne alignment study).
corey.gray@LIGO.ORG - 08:41, Friday 18 November 2016 (31586)OpsInfo

As of this week, we want to run the ...LHO.py file at the beginning of locks (i.e. right after we reach NLN).  It takes on the order of 10min.  

Sometimes you might not want to run it.  If the DARM specrtra looks good around 20Hz, then you are good.  It's a judgement call, but in general, this helps with sensitivity.  Will put this in the Ops Sticky Note wiki & should get in the Ops Checksheet soon.

(Thanks to Jenne & Ed for sharing the alogs about this!)

Displaying reports 58941-58960 of 89678.Go to page Start 2944 2945 2946 2947 2948 2949 2950 2951 2952 End