Displaying reports 63001-63020 of 88171.Go to page Start 3147 3148 3149 3150 3151 3152 3153 3154 3155 End
Reports until 01:01, Thursday 03 March 2016
H1 ISC
sheila.dwyer@LIGO.ORG - posted 01:01, Thursday 03 March 2016 (25853)
ASC tonight

Rob, Lisa, Matt Evan Sheila Patrick

Tonight we were able to get back to locking on RF, but were unable to engage the soft loops.  (we were stable with all other ASC on)  We spent some time trying to understand the problem. It seems possible that 90MHz centering will help aleviate this problem.  

We watched all the top mass control signals as we turned on CSOFT P, with the SRC1 loops open and the AS centering on DC.  We saw that all test masses move as expected, but so do the other optics, including PR3, PRM, SR3, and BS.   The second attached screenshot shows how the OMs are driven by the centering loops, which see the CSOFT change.  We hypothesize that this is how CSOFT couples to the BS and other loops, and also see this signal in the 90MHz centering signals wich are out of loop here.  

We looked a little bit at using 90 MHz centering, but see some problems.  

For one, the 90MHz signals are not normalized by the sum, they are normalized by the input power.  It seems like we should be using the signals normalized by the sum, and that this would be a fairly simple model change replacing the input power normalization with the sum.  If we normalize this way we can simply use 1s in the input matrix and the centering loop gains should stay the same.  

The sum on ASARF90 is negative, so this centering loop might have a sign flip compared to the DC centering.  

We measured the MICH ASC looop to do a comparison between the gain with 90MHz centering on and with DC centering on.  While doing this we turned off the centering loops, and saw that the MICH loop was not stable this way.  This probably means that the MICH ASC loop stability somehow depends on the centering loop, and that we need to make sure we keep the centering loop BW the same when we change sensors.  

For the first people to come in the morning to work on locking, some good steps would be:

1) Add normalization of the 90 MHz centering to the ASC models. 

2) Measure the MICH ASC loops (templates available /ligo/home/evan.hall/Public/Templates/MichPitchSweep.xml and MichYawSweep.xml ) with the DC centering on.

3)measure the centering loop OLGs, for DC centering and 90 MHz centering.  

4) measure the MICH ASC OLGs with the 90 MHz centering on.  Make sure the gain is the same as for DC centering.  

Images attached to this report
H1 ISC
evan.hall@LIGO.ORG - posted 00:23, Thursday 03 March 2016 (25852)
DARM-to-OMC modematching at 2 W

Matt, Lisa, Evan

We wanted to remeasure the modematching of the DARM mode into the OMC. At 2 W, the mode mismatch is 2% to 2.5%.

To do this, we used the eLIGO technique of looking at the DARM signal in the OMC reflection QPDs, with the OMC locked and unlocked. Whatever DARM residual is still present in reflection of the locked OMC indicates the amount of mode mismatch.

The attachment shows some of the test mass violin mode first harmonics, as seen in reflection of the OMC. Only about 2% to 2.5% of the DARM signal remains after the OMC is locked.

We need to get data at 20+ W in order to infer the mode mismatch during low-noise operation.

The OMC was unlocked from 07:16:00 to 07:21:00, and it was locked from 07:24:30 to 07:29:30 (all times 2016-03-03 Z).

Images attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 00:11, Thursday 03 March 2016 (25851)
Ops Evening Shift Summary
0:29 UTC Kiwamu to hartmann table by HAM4 to take pictures
0:43 UTC Kiwamu back

Evan, Sheila, Jenne, Matt and Lisa working on ASC.
H1 AOS
sheila.dwyer@LIGO.ORG - posted 23:06, Wednesday 02 March 2016 (25850)
AS36 B phases reverted

Since we are looking at ASC we reverted the AS36 B phases which were adjusted durring the day.  The settings are attached (the setpoints were the AS90 team phasings)  just in case people want a record.

Images attached to this report
H1 AOS
hang.yu@LIGO.ORG - posted 21:28, Wednesday 02 March 2016 (25849)
ASC WFS w/ 90 MHz Centering

Jenne, Hang

We tried more WFS phasing with AS 90 as our centering loop today. 

## AS B 36 I:

We first looked at AS B 36 I and tried to use it for SRM sensing. We excited a length signal first and phased each segment s.t. the signal showed up in I phase, to fix the relative phase between the segments. We found that the demod phase of segs. 3 & 4 was 90 deg diff than that of segs. 1 & 2. Then we drive SRM in pitch (yaw) and rotated the demod phase for all quardrants together to optimize the angular signal in I phase. However, we could not close the SRC loop even after re-phasing. By applying a static misalignment to SRM, we found the AS 36 B I responsed only to one direction but not the other. No clue why this was the case yet.

 

## AS A 36:

We then decided to use only AS A 36, with Q phase for BS and I for SRM. The demod. phase was set by maximizing BS angluar signal in Q (w/ 90 centering, DRMI locked). 

The new (old) demod phase for the 4 quardrants were:

-165 (-140); -145 (-140); -145 (-140); -135 (-140)

At this config., for BS, the Q signal was factor ~ 10 of the I signal, and for SRM, the I signal was factor ~3 of Q.

 

## Difficulties w/ locking the IFO:

After that we tried to go further in the locking sequence, but kept losing lock at RF_DARM/DHARD_WFS. 

We first noticed that the DARM gain at RF_DARM was too large for the new config. We set it to 400 instead of increasing to 1000. Also the DHARD pit & yaw gains were too high. We decreased it by a factor of 10 and saw some oscillation at 15 Hz when offloading was almost done. Then we reverted all settings and handed the IFO to noise-hunting team. 

 

## Things to do:

Rephase the 90 centering WFS. The last time we did it we did not open the MICH ASC loop. Then recheck all other WFS' phasing again. If we still have trouble locking at the DHARD_WFS, stage, we may further decrease the DHARD pit/yaw gains by another factor of ~4ish. We may also just commented out the new offloading gains.

H1 TCS (TCS)
aidan.brooks@LIGO.ORG - posted 19:28, Wednesday 02 March 2016 (25846)
TCS IFO SIM model updates - arm cavity g-factor, PRC/SRC RT Gouy Phase, arm cavity HOM spacing

I updated the TCS IFO model/simulation page. The major changes and additions are summarized below:

OPTIC LENS/ROC model (left side of screen):

IFO SIMULATOR:

This is a set of calculations of interferometer values that are dependent on ROC and ITM lenses

The MEDM screen is being (slowly) updated to illustrate these parts

SITEMAP > TCS > MASTER > SIMULATION

 

Images attached to this report
H1 ISC (ISC)
matthew.evans@LIGO.ORG - posted 18:28, Wednesday 02 March 2016 - last comment - 10:27, Monday 07 March 2016(25847)
DARM noise fluctuation vs. LVEA Temperature

Plotting the cross-correlated DARM noise (band 5) and LEVA temperature on the same plot doesn't show any obvious relationship.  The .fig is included in case someone has a good idea of how to use this data.

Images attached to this report
Non-image files attached to this report
Comments related to this report
lisa.barsotti@LIGO.ORG - 19:23, Wednesday 02 March 2016 (25848)
This analysis has been inspired by the recent investigations on the  L1 noise , that shows some correlation of DARM variations vs LVEA temperature.

By superimposing the current best L1 curve and the best H1 curve from O1 (see plot), one can see that the noise in the L1 bucket seems to have more "scattering looking" peaks (which can be modulated by temperature-induced alignment variations), while the H1 noise less so. 

The noise at high frequency is notably lower in L1, mostly due to the higher cavity pole frequency. 

Non-image files attached to this comment
kiwamu.izumi@LIGO.ORG - 14:50, Friday 04 March 2016 (25882)DetChar

I have extended Matt's previous analysis to the entire O1. In addition, I added another interesting channel, the vertical sensor of the top stage of ITMY. Here is the result.

I went through trend of some interesting channels where I was looking for signals showing similar variation to the band limited rms of the cross spectra. I came across ITMs' top stage vertical monitors and found them showing two relatively big bumps (actually dips in the raw signals) which seemingly match the ones in the band limited rms on Dec 2nd and Dec 29th. However, even through they look like showing a good agreement in the last half of the O1 period, the first half does not show an obvious correlation. Does this mean that the modulation mechanism of the noise level changed in the middle of the run and somehow noise level became sensitive to vertical displacement of ITMs or in-chamber temperature ?

Images attached to this comment
Non-image files attached to this comment
kiwamu.izumi@LIGO.ORG - 10:27, Monday 07 March 2016 (25910)

For completeness, I have looked at other vertical monitors. Here is the result. They all show qualitatively the same behavior more or less. The fig file can be found on a server.


 

Images attached to this comment
H1 CDS
david.barker@LIGO.ORG - posted 17:18, Wednesday 02 March 2016 (25845)
/ligo file system filled this morning

Carlos, Dave:

The /ligo file system filled up  this morning. Carlos did an emergency move of /ligo/backups/alog over to the ops-home disk. Later we built a file system on a spare 2TB disk Carlos had installed on cdsfs0 and we moved the Guardian log files backup directory over to it. This freed up 112GB of disk space. Along with other cleanup work /ligo currently has 143GB of disk available. We hope this carries us through to the install of the new cdsfs0 NFS server scheduled for Tuesday 8th.

H1 General
cheryl.vorvick@LIGO.ORG - posted 16:17, Wednesday 02 March 2016 - last comment - 08:20, Thursday 03 March 2016(25843)
Ops Day Summary:

Day Shift 16:00-23:59UTC (08:00-16:00PT)

State of H1: DRMI lock for Jenne

Shift Summary:

Site Activities:

- 19:30 Kyle - LVEA to survey for upgrade

- 19:45 Kyle - out of LVEA

- 21:27 Corey - optics lab

- 21:15 Ed - LVEA to reset PSL watchdog

- 21:25 Ed - out of PSL

 

Locking / Initial Alignment:

- locking X arm in red was very fast, and had good power

- ITMY needed more of an offset during SRC alignment

- PRMI needed to adjust BS for DRMI

- DRMI is well aligned and relocking quickly for the last 2-3 hours of the shift

 

Control Room:

- Video0 froze, now fixed after a reboot

- Video4 had the wrong striptool displayed, now fixed

Comments related to this report
cheryl.vorvick@LIGO.ORG - 16:40, Wednesday 02 March 2016 (25844)

ITMY mis-alignment issue tracked down to offset, now fixed.

ITMY drivealign_P2L_gain change from 1.05 to 0.6 accepted after the OK by Sheila, had been 0.6 for at least 10 days.

Images attached to this comment
edmond.merilh@LIGO.ORG - 08:20, Thursday 03 March 2016 (25854)

The Front End watchdog reset takes place in the LASER Diode Room, not in the LVEA/PSL enclosure. :)

H1 SEI (ISC)
jim.warner@LIGO.ORG - posted 14:34, Wednesday 02 March 2016 - last comment - 09:44, Friday 04 March 2016(25842)
Plans for wind fence testing at LHO

I've been slowly trying to get stuff figured out for testing a wind fence set up at LHO, and am getting ready to try to set something up. I'll summarize where I think things are here.

Currently, I want to try a small, cheap wind fence at EX, mostly to explore how effective screens are at slowing wind, effects on ground motion and tumbleweed build up. The fence would be a couple of 4x4-ish 12-15 foot posts and some fine polymer netting like that used around tennis courts, gardens and the like. It may be necessary to add guy lines, as well.  In addition to the fence, Richard has said he will help me get an STS buried at EX, similar to Robert's set up at EY, and we are ordering 3 anemometers with stand alone data collection so no changes need to be made to CDS for this. I think this set up will allow me to look at a few of the concerns that people have brought up. So far the concerns I've heard are:

1. Increased ground motion. Fences slow wind by applying a force to the airstream, this is transmitted to the ground and produces increased tilt and other high frequency motion. I think the tilt can be addressed by placing the fence some few tens of meters from the building, per Robert's measurements of building tilt. Higher frequency motion can hopefully be addressed by design of the fence support structure, but we'll have to see how bad the motion is.

2. Similarly, the fence could make airflow more turbulent. I suspect that airflow at the building level is probably turbulent anyway. Hopefully, a well designed fence push turbulent flows around the building, while slowing most of the air makes it through.

3. Tumbleweed build up. Anything that blocks the wind will gather tumbleweeds around here, which could make a fence a fire hazard and maintenance issue.  This  could be addressed by leaving a gap at the bottom. The airflow below a few feet probably isn't a significant source of problems for us, but I don't know how big this gap would need to be. I also plan on using a mesh fine enough that tumbleweeds won't stick to the fence very easily. Industrial fences are flame resistant, and won't ignite on their own.

4. Wind damage. We have seen winds above 100 mph during a storm, this would create very high loads on any fence. I haven't been able to figure out how to calculate wind loads on a permeable wall yet, but Civil Engineers have building codes dealing with this. For my test, I'm trying to get some idea of the loads involved with moderatewind, and just making the fence so that the mesh will tear free in a way that won't damage the EX building if the wind gets too bad. Industrial fences are designed to stand similar wind loads, and their screens are held in place with replaceable break-away clips to prevent damage.

5. Cost/size. BrianL talked to a company that makes industrial fences a few months ago. The ball park figure for a 40 x 200 foot fence was about $250,000. That was a first pass at a price and the company had some suggestions at how to cut down on the cost. This price also needs to be weighed against the 10-15 % of down time we have due to wind. Something of that size would also probably have to be approved by the DOE. It's also unclear if we would have to completely surround each endstation, or if we could get away with less coverage. Probably, we don't need to "protect" EY along the X-axis, or EX along the Y-axis.

Comments, criticism, praise are all welcome.

Comments related to this report
john.worden@LIGO.ORG - 08:29, Thursday 03 March 2016 (25855)

Comments;

Any break away components will need to be constrained so the EPA doesn't come after us for polluting the desert. I suggest that even a temporary test fence be built to withstand any expected wind/snow/tumbleweed loads.

Be aware that any wind speed and direction measurements are likely influenced by ground effects until you are well above the ground and nearby obstructions - say 25- 50 feet???

brian.lantz@LIGO.ORG - 09:44, Friday 04 March 2016 (25879)FMP
Thanks John. 
The ones I saw advertised had a cable top and bottom which suspended the wind fabric. The top attachments from the fabric to the cable were "permanent" and the attachments to the lower cable were the break-away. This should allow it to yield to the wind load, but to keep it from blowing away and causing more trouble.
H1 ISC (ISC)
matthew.evans@LIGO.ORG - posted 14:12, Wednesday 02 March 2016 (25841)
DARM noise fluctuation

Along the same lines of earlier investigations into DARM noise fluctuations, I checked the "high frequency" (1-100mHz) spectrum of the DARM RMS in 2 bands between 80 and 100Hz.  The fluctuations in these BLRMSs are fairly featureless, though there appear to be small peaks at 30 and 70mHz (see plot).

The code used to generate these plots is:

gwd = GWData;
data7 = gwd.fetch('26 Dec 2015 8:00:00', 3*60*60, 'H1:SUS-ETMX_L2_DAMP_MODE7_RMSLP_OUT16', 'mDV');
dd7 = GWFilt.detrend(data7.data);
fs = data7.rate; tfft = 256;
[p7, ff] = pwelch(dd7, hann(fs * tfft), [], fs * tfft, fs);

data8 = gwd.fetch('26 Dec 2015 8:00:00', 3*60*60, 'H1:SUS-ETMX_L2_DAMP_MODE8_RMSLP_OUT16', 'mDV');
dd8 = GWFilt.detrend(data7.data);
[p8, ff] = pwelch(dd8, hann(fs * tfft), [], fs * tfft, fs);

loglog(ff, [p7, p8]); axis([0.005, 0.2, 1e-4 1e-2]); grid on
title('Flucutations in DARM noise (Boxing Day 2015)')
legend('80-100Hz band', '100-120Hz band')
xlabel('frequency [Hz]')
ylabel('Power spectrum of variations')

Images attached to this report
H1 General (PSL)
edmond.merilh@LIGO.ORG - posted 13:56, Wednesday 02 March 2016 (25839)
Reset PSL FE Watchdog

The watchdog was reset at 13:22PST as per FAMIS http:// https://ligo-wa.accruent.net/LB_Request_Update.asp?RequestID=3587

H1 GRD
thomas.shaffer@LIGO.ORG - posted 10:53, Wednesday 02 March 2016 - last comment - 12:52, Wednesday 02 March 2016(25837)
Testing PSL Guardian Node

I took advantage of the the earthquake and the higher winds this morning and went to test out a new PSL node. Much of the code was taken from LLO's PSL guardian, but I tweaked it for our uses and added a few things that they didn't have. After I created the node, I could not get "guardctrl medm" to pop up a medm for the node.  (shot of the error attached) In the interest in time, I continued just using the the log and other guardctrl commands. This is much more awkward that I expected and slowed me down quite a bit. After sorting through the few syntax errors, bringing the power up and down, and searching for home, I have some notes and will work on a few issues I found. Overall, it went well and it should, hopefully, be usable very soon.

I stoped and destroyed the node when I was done, I will recreate it next chance I get to test it (whenever that may be).

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 12:52, Wednesday 02 March 2016 (25838)

Completely spaced and did not use "guardmedm". This would have worked for what I needed.

H1 General (VE)
cheryl.vorvick@LIGO.ORG - posted 09:36, Wednesday 02 March 2016 - last comment - 10:02, Wednesday 02 March 2016(25835)
Site activities - H1 Update: at 17:35UTC (9:35PT)

Site activities:

- 17:16UTC Kyle and Gerardo - at EX and door X2-8 to work on cable for annulus ion pump

 

H1 Update:

- 17:53UTC all ISI platforms returned to nominal isolation

Comments related to this report
cheryl.vorvick@LIGO.ORG - 10:02, Wednesday 02 March 2016 (25836)

Ex work on hold until the road is cleared of tumbleweeds.

LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 15:55, Tuesday 01 March 2016 - last comment - 14:12, Wednesday 02 March 2016(25816)
X-End Neg Regeneration

(Chandra, Gerardo and Kyle)

Regenerated NEG pump with the aid of an aux cart.

Valved out NEG pump from X-End, then started regeneration of NEG pump ~19:00 utc.
2 hours later heating was complete, waited for temperature to drop down, valved in NEG pump to X-End volume at 21:45 utc and @ 92 deg C.

Comments related to this report
john.worden@LIGO.ORG - 14:12, Wednesday 02 March 2016 (25840)

Pressure plots attached.

-Chandra

Images attached to this comment
Displaying reports 63001-63020 of 88171.Go to page Start 3147 3148 3149 3150 3151 3152 3153 3154 3155 End