Displaying reports 6681-6700 of 89075.Go to page Start 331 332 333 334 335 336 337 338 339 End
Reports until 16:50, Thursday 05 June 2025
H1 General
anthony.sanchez@LIGO.ORG - posted 16:50, Thursday 05 June 2025 (84837)
TCS Monthly Trends

TCS Monthly Trends FAMIS 28461

ITMY SLED power is decreasing in power.
I trended these channels back to before the vent and all of these plots seem to have abnormal values due to the vent and various other tinkerings, like swapping out the SLEDs.

Images attached to this report
H1 General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:28, Thursday 05 June 2025 (84835)
OPS Eve Shift Start

TITLE: 06/05 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: Ibrahim
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 13mph Gusts, 8mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.11 μm/s
QUICK SUMMARY:

(This is Oli)

We just lost lock while trying to run a calibration measurement, so we're working on relocking.

H1 CAL
ibrahim.abouelfettouh@LIGO.ORG - posted 16:27, Thursday 05 June 2025 - last comment - 11:22, Tuesday 10 June 2025(84834)
(Incomplete) Calibration June 5, 2025

(This is Oli)

Once we had been at 60W for two hours, I started a calibratoin measurement. I started with Simulines since yesterday I had gotten a broadband measurment done (84808). A couple minutes into the measurement, we lost lock. The cause is unknown, but I've attached the output for the simulines measurement (txt).

Images attached to this report
Non-image files attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 16:56, Thursday 05 June 2025 (84836)

Lockloss happened as Calibration signals were ramping on, see attached. First glitch in L3, see attached.

Images attached to this comment
francisco.llamas@LIGO.ORG - 11:22, Tuesday 10 June 2025 (84925)

Attaching trend of OMC DCPD sum during LL. Plot suggests the DCPDs were not the cause of the lock-loss.

Images attached to this comment
H1 PEM (ISC)
jennifer.wright@LIGO.ORG - posted 15:57, Thursday 05 June 2025 (84830)
PSL periscope coupling to DARM?

Jennie W, Robert S, Sheila, Camilla, Georgia

 

We are worried about jitter peaks in DARM and input pointing just now so Camilla and Sheila asked me to look at the PEM accelerometer we have on the main periscope in the PSL.

The first image is a time series of periscope acceleration on the top, lock state in the middle and range on the bottom. The first vertical cursor shows a time when we were locked at NLN before the vent on 1st April, and the second is during a quiet time with no squeezing injected that Camilla and co. were using for squeeze measurements yesterday 4th June. One can see that the rms motion increased from around 670 counts before the vent to around 1200 after the vent.

The second image shows the spectra of the accelerometer on the top left plot, the darm spectra on the bottom left, and the coherence from accelerometer to darm on the top right plot - plotted for both times.

Ref 0 periscope asd now

ref 1 periscope asd pre-vent

ref 2 darm asd pre-vent

ref 3 periscope to darm coherence pre-vent

ref 4 periscope to darm coherence post-vent

ref 5 darm asd post-vent

After looking over these with Robert, he thinks that the jitter is not much higher up to about 200 Hz but noticeably worse between 500 Hz and 1kHz. There have been vacuum pumps attached to HAM1 post-vent, but these would not cause the broadband features we can see in this region and would instead be reponsible for narrow peaks.

 

He wants to check the air handling in the PSL enclosure to rule this out as a source.

Since the coherence with DARM is not big for these peaks this will not be causing our jitter problems currently.

Images attached to this report
H1 ISC
camilla.compton@LIGO.ORG - posted 15:14, Thursday 05 June 2025 - last comment - 17:01, Thursday 05 June 2025(84827)
PRMI ASC, edited but untested and unimplemented

Georgia, Sheila, Camilla

PRMI ASC feedback on PRM hasn't been successfully used since the vent. The operators have been by hand touching up PRM.

We looked at this data for PIT (attached today plot) and YAW (attached yesterday plot). Using the same sensor, REFL_A_RF9_I, is fine, zero crossings of signals are good. The YAW sign is wrong. Have changed the gain in ISC_DRMI.py  for ASC-PRC1_Y_GAIN from -0.1 to +0.1 and reloaded. It will get set back to zero by the guardian so shouldn't effect anything else.

This is untested and left off: to test you would need to change line155 of /isc/h1/guardian/lscparams.py to set PRMI ASC to True.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 17:01, Thursday 05 June 2025 (84839)

Elenna, Jennie, Camilla

We tested these before turning on, YAW worked great, PIT did not, see attached error signal not coming to zero as alignment is improved. Unsure what has changed but Elenna and Sheila saw similar weirdness in PRX this AM. Can try again next week.

Images attached to this comment
H1 CDS
david.barker@LIGO.ORG - posted 14:42, Thursday 05 June 2025 (84828)
DARM FOM stopped updating, DMT issue found

Jonathan, Georgia, Dave:

The DARM FOM on nuc30 stopped updating. After verifying there had been no recent network disconnection, I tried restarting the DARM with no success. I then failsafed back to the CDS only XML (no reference spectra from DMT) and this started running.

Jonathan found there was indeed a DMT issue, starting around 11:50 this morning. He is investigating. In the mean time Georgia says the local DARM is sufficient.

Images attached to this report
LHO VE
janos.csizmazia@LIGO.ORG - posted 14:14, Thursday 05 June 2025 - last comment - 17:16, Thursday 05 June 2025(84826)
HAM1 annulus leak hunting, IP3 troubleshooting
Jordan, Gerardo, Travis, Marc, Fil, Janos - WP 12591

Today, starting at 8:00 am Gerardo and Jordan leak checked the HAM1 annulus system, by connecting a leak checker to the annulus pumping turbo, and of course valving out / switching off the annulus IPs. At first, the all-metal parts of the system have been checked, mostly on top of HAM1. Those were found OK. Then, the Y- door was checked with sniffing He in the leak checking grooves, then after a few seconds flushing it with Nitrogen. Y- door was found OK, too. Then, the Y+ door was checked with the same method, and the bottom half of it showed huge leaks. Therefore, the chamber needs to be re-vented, most likely the O-rings replaced, and the door reinstalled. This will take place tomorrow (06-06).

In the meantime, IP3 was diagnosed, and troubleshooted. Travis and myself swapped the 2 HV cables on the Ion pump, and the same half of the pump remained functional, which indicated that there is a cable failure (together with the consequences of aLog 84761). So we pulled in a legacy H2 (former IP7) cable, and tested, but without success.
Then Marc and Fil jumped in, and after a while we figured that in the MER we plugged the wrong cable in the controller, due to wrong cable labeling. In the end, Marc and myself went back into the LVEA, made sure that the LVEA-end of the currently plugged cable is indeed not connected, then we searched for the appropriate cable-end in the MER, plugged it in to the controller, and so now the IP is working again. The only last thing remaining is to valve it back in to the main volume.
Comments related to this report
gerardo.moreno@LIGO.ORG - 17:16, Thursday 05 June 2025 (84840)VE

Filiberto and I went to the mechanical room to look the different components on the vacuum racks, primarily the location of the ion pump controllers, and to our surprise we found the controller for IPFCC1, see trend for time it was off.  Found that the power cable can be easily shaken off, we removed and replaced the power cable, much better fit with the new one.  As power is restored the controller powered back on and restored high voltage to the pump.

Images attached to this comment
H1 GRD
ryan.short@LIGO.ORG - posted 14:09, Thursday 05 June 2025 (84823)
ALIGN_IFO Error with INIT Request from Protected State

Sheila and Elenna noticed strange behavior with the ALIGN_IFO node early this afternoon where they were doing the 'OFFLOAD_PRC_ALIGN' state and mistakenly requested 'DOWN' and 'INIT' before the offloading was finished, and the Guardian jumped mid-offload, leaving things in a weird state.

This is not ideal, as the offloading states in this node are meant to be "protected" (redirect=False) and the Guardian should not leave these states unless they return True, even with a redirect request. I've highlighted in the Guardian log below that the initial requests for the 'PRX_LOCKED' and 'DOWN' states were correctly ignored, but a request for 'INIT' prompts an "INIT redirect," which then waits for one second for worker completion, which finishes, then terminates the worker. This restarts the code, which starts the node at 'INIT.'

Is INIT a special state which overrides a protected state? Why did the worker crash in this case? These are questions still under investigation.

ryan.short@cdsws25[~]: guardctrl log ALIGN_IFO -a 1433187576 -b 1433187587
2025-06-05_19:39:18.240855Z ALIGN_IFO [OFFLOAD_PRC_ALIGNMENT.main] ezca: H1:SUS-RM2_M1_LOCK_Y => OFF: INPUT
2025-06-05_19:39:18.241603Z ALIGN_IFO [OFFLOAD_PRC_ALIGNMENT.main] ezca: H1:SUS-RM2_M1_LOCK_Y_GAIN => 0
2025-06-05_19:39:18.241978Z ALIGN_IFO [OFFLOAD_PRC_ALIGNMENT.main] ezca: H1:SUS-RM2_M1_OPTICALIGN_Y_TRAMP => 10
2025-06-05_19:39:18.242418Z ALIGN_IFO [OFFLOAD_PRC_ALIGNMENT.main] ezca: H1:SUS-RM2_M1_OPTICALIGN_Y_OFFSET => -836.7946
2025-06-05_19:39:18.242518Z ALIGN_IFO [OFFLOAD_PRC_ALIGNMENT.main] waiting for ramps to finish...
2025-06-05_19:39:22.706911Z ALIGN_IFO REQUEST: PRX_LOCKED
2025-06-05_19:39:22.708302Z ALIGN_IFO calculating path: OFFLOAD_PRC_ALIGNMENT->PRX_LOCKED
2025-06-05_19:39:22.709109Z ALIGN_IFO new target: DOWN
2025-06-05_19:39:22.709931Z ALIGN_IFO GOTO REDIRECT IGNORED: redirect=False for state OFFLOAD_PRC_ALIGNMENT
2025-06-05_19:39:25.447181Z ALIGN_IFO REQUEST: DOWN
2025-06-05_19:39:25.448398Z ALIGN_IFO calculating path: OFFLOAD_PRC_ALIGNMENT->DOWN
2025-06-05_19:39:25.448771Z ALIGN_IFO GOTO REDIRECT IGNORED: redirect=False for state OFFLOAD_PRC_ALIGNMENT
2025-06-05_19:39:27.193260Z ALIGN_IFO REQUEST: INIT
2025-06-05_19:39:27.194773Z ALIGN_IFO INIT redirect
2025-06-05_19:39:27.194773Z ALIGN_IFO REDIRECT requested, timeout in 1.000 seconds
2025-06-05_19:39:27.197640Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:27.269261Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:27.328470Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:27.395177Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:27.448378Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:27.516500Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:27.581382Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:27.638191Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:27.709034Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:27.773263Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:27.828997Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:27.881440Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:27.949812Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:28.014862Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:28.077071Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:28.132765Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:28.203338Z ALIGN_IFO REDIRECT wait for worker completion...
2025-06-05_19:39:28.204112Z ALIGN_IFO REDIRECT timeout reached. worker terminate and reset...
2025-06-05_19:39:28.214558Z ALIGN_IFO worker terminated
2025-06-05_19:39:28.227354Z ALIGN_IFO W: initialized
2025-06-05_19:39:28.254897Z ALIGN_IFO W: EZCA v1.4.0
2025-06-05_19:39:28.254897Z ALIGN_IFO W: EZCA CA prefix: H1:
2025-06-05_19:39:28.254897Z ALIGN_IFO W: ready
2025-06-05_19:39:28.256840Z ALIGN_IFO worker ready
2025-06-05_19:39:28.261318Z ALIGN_IFO EDGE: OFFLOAD_PRC_ALIGNMENT->INIT
2025-06-05_19:39:28.262024Z ALIGN_IFO calculating path: INIT->DOWN
2025-06-05_19:39:28.262914Z ALIGN_IFO new target: DOWN
2025-06-05_19:39:28.273539Z ALIGN_IFO executing state: INIT (0)
2025-06-05_19:39:28.274460Z ALIGN_IFO [INIT.enter]
2025-06-05_19:39:28.275951Z Warning: Duplicate EPICS CA Address list entry "10.101.0.255:5064" discarded
2025-06-05_19:39:28.316393Z ALIGN_IFO REQUEST: PRX_LOCKED
2025-06-05_19:39:28.322564Z ALIGN_IFO calculating path: INIT->PRX_LOCKED
H1 ISC
elenna.capote@LIGO.ORG - posted 13:58, Thursday 05 June 2025 - last comment - 14:49, Thursday 05 June 2025(84824)
DHARD P 1 Hz peak appears in low bandwidth state

Since we slowly stepped through the LOWNOISE ASC state yesterday, I was able to plot ASDs of the DHARD P error signal and determine what exactly creates the 1 Hz peak. My hypothesis was it was something from the damping loops, but I was wrong! The peak appears after we engage the low bandwidth DHARD P controller. I will take a look at the loop design and adjust to reduce this peak. My guess right now is some gain peaking is present at 1 Hz.

Attachment shows the sepctrum of the error signal during the state. If you are looking at the calibration lines in DHARD P and getting worried- this was before we fixed the A2L gains, and in full lock low noise there are no cal lines present in either DHARD P or Y.

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 14:49, Thursday 05 June 2025 (84829)

We also have a 1 Hz ring up that sometimes appears after the lownoise ASC state. It has impacted our interferometer locking during this period, but "around the control room" we think that this has been a problem that appears time to time even before this vent recovery. It may show up during the ETMX transition states since it is a fairly slow ring up (occurs about 3-5 minutes after the control is changed).

I'm looking at the boosts we have engaged in DHARD to determine if we need them all, because they are stealing a lot of phase at 1 Hz and probably causing this problem.

H1 ISC
sheila.dwyer@LIGO.ORG - posted 13:10, Thursday 05 June 2025 (84819)
ALS X green camera not pointed well

It looks like the ITMX green camera is poorly centered.  We should repoint this soon, as we are using it for green alingment.

Images attached to this report
H1 ISC
elenna.capote@LIGO.ORG - posted 12:47, Thursday 05 June 2025 (84818)
Mystery PR3 yaw move

Ibrahim, Sheila, Elenna

We were having trouble in the "FIND IR" state, ans Sheila realized that it was due to the guardian thinking the x-arm alignment was poor. However, X arm had locked fine and Ibrahim had run the initial alignment. We asked Ibrahim to run it again, and noticed that it continued to lock the X arm green with a transmission of 0.6 (when it should be like 1). However, the convergence of the WFS and camera signals did not improve the arm alignment.

We saw that the COMM beatnote was also low, so I trended PR3 osems. The OSEMs show a few microradian movement in pitch and no movement in yaw. I tried moving PR3 pitch in the "right" direction according to the osems, but it only made the beatnote worse. Same moving in the opposite direction. Based on the ALS X camera, it looked like the beam was off in yaw, so I instead moved PR3 in yaw, which returned the beatnote to a good place and increased the X arm transmission to >1. So, we are baffled, but we trust our current table alignment so we are going to go with this PR3 placement. Overall, this is a 2 microradian movement in PR3 yaw to regain the beatnote/ALS X transmission.

The y cursor on the top plot shows the pitch position of PR3 two weeks ago when we originally aligned the table. There was not a significant change in PR3 yaw in the osem.

Images attached to this report
H1 ISC
sheila.dwyer@LIGO.ORG - posted 11:55, Thursday 05 June 2025 (84817)
removed BS bounce roll notch from LSC MICH2

In light of 84770 and 84811, I've taken BR0604 out of the MICH LSC loop.  This filter was added to try to address a line in DARM, but didn't ulitmately help with that line, 78205

The filter is costing us 50 degrees of phase at 16.9 Hz, where this loop has been ringing. 

This morning the DRMI problem wasn't happening, it seems to be happening in the evenings lately. 

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:33, Thursday 05 June 2025 - last comment - 15:10, Thursday 05 June 2025(84814)
Thu CP1 Fill

Thu Jun 05 10:09:05 2025 INFO: Fill completed in 9min 2secs

 

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 15:10, Thursday 05 June 2025 (84831)

TC-A stayed cold (<-80C) after the fill. I knocked an ice ball off the end of the discharge line which seems to have done the trick.

H1 General (ISC)
oli.patane@LIGO.ORG - posted 22:18, Wednesday 04 June 2025 - last comment - 13:46, Thursday 05 June 2025(84811)
Ops Eve Shift End

TITLE: 06/05 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: None
SHIFT SUMMARY:

Just put the IFO in DOWN for the night after losing lock from ENGAGE_ASC_FOR_FULL_IFO. I was having trouble all evening getting DRMI to stay locked - we kept losing lock from the 16.2 Hz oscillation that Craig and Elenna had found yesterday (84769). I have no idea why it's only been appearing in the evenings - yesterday evening we had these issues, then this morning no issues at all, and then this evening issues again!! I would lose lock from it anytime after ENGAGE_DRMI_ASC, but even just in DRMI_LOCKED_PREP_ASC, the oscillation was there, just not ringing up.

One of the times I was able to get DRMI to lock, I stayed in DRMI_LOCKED_PREP_ASC and took MICH, PRCL, and SRCL OLG measurements. Later on, Sheila called and figured out it must be due to the MICH gain being too high, so I lowered MICH2 gain, originally at 1, by 30% to 0.7. After doing that, the 16 Hz oscillation went away (diaggui) and we were able to get through DRMI. Sheila said we probably needed that gain back to 1 for DRMI_TO_POP, so I paused at RESONANCE, reset the MICH2 gain to 1, and then continued. We lost lock during ENGAGE_ASC_FOR_FULL_IFO.

So the MICH2 gain is currently at its original gain of 1.

Evening task progress for today:

LOG:

23:30 Sitting in NOMINAL_LOW_NOISE while tests are being run
00:32 Started BB calibration measurement
00:37 BB measurement done
00:38 Lockloss due to earthquake
    - started a manual initial alignment
        - tried to leave SCAN_ALIGNMENT for UNLOCKED and got a Guardian node error about the time being in the past - had to manual before reloading to get out of it (txt)
    - After the initial alignment was done, I relocked SRY and left it there for a while while Vicky and Kevin worked on SQZ stuff
    02:24 Lockloss from ENGAGE_DRMI_ASC due to the 16.2 Hz oscillation (84769)
    02:37 Lockloss from TURN_ON_BS_STAGE2 due to the 16.2 Hz oscillation
        - I paused in DRMI_LOCKED_PREP_ASC and adjusted SRM to make POP look better, then went into ENGAGED_DRMI_ASC. We had an oscillatoni start, but we were able to survive it. Then I went into TURN_ON_BS_STAGE2 and we immediately lost lock
    03:24 Lockloss from ACQUIRE_DRMI_1F while trying to acquire. We had gotten it earlier and I stayed in DRMI_LOCKED_PREP_ASC and took MICH, PRCL, and SRCL OLG measurements, but we lost DRMI when I aborted the SRCL measurement and we weren't able to grab it again
    03:40 Lockloss from ACQUIRE_DRMI_1F
    - Ran another initial alignment
    04:20 Lockloss from TURN_ON_BS_STAGE2 due to the 16.2 Hz oscillation
    04:31 Lockloss from ENGAGE_DRMI_ASC due to the 16.2 Hz oscillation
    - Sheila called, I lowered MICH2 gain (originally at 1) by 30% to 0.7, then the 16 Hz oscillation went away and we were able to get through DRMI
    - Paused at RESONANCE, reset the MICH2 gain to 1, and then continued
    04:58 Lockloss from ENGAGE_ASC_FOR_FULL_IFO

Start Time System Name Location Lazer_Haz Task Time End
00:44 VAC Gerardo LVEA YES Moving a ladder by HAM4 01:21
Images attached to this report
Comments related to this report
oli.patane@LIGO.ORG - 13:46, Thursday 05 June 2025 (84821)GRD

I forgot to actually attach the text file for the ALS_XARM error I got last night, so here it is

Non-image files attached to this comment
H1 CAL
oli.patane@LIGO.ORG - posted 18:12, Wednesday 04 June 2025 - last comment - 10:44, Friday 06 June 2025(84808)
(Incomplete) Calibration Measurements June 5th, 2025

I was only able to take the broadband measurement due to an earthquake that knocked us out of lock a minute later. We had been at full power for around 5 hours at the time this measurement was run. Unfortunately since we weren't able to take the Simulines measurements, I am not able to run the report.

Broadband:

Start time: 1433118749 (2025-06-05 00:32:11 UTC)

End time: 1433093874 (2025-06-05 00:37:36 UTC)

Data found in: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250605T003226Z.xml

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 11:01, Thursday 05 June 2025 (84815)

Attached the screenshot of the broadband measurement as a quick reference for us before we have a chance to take the full measurements.

Images attached to this comment
elenna.capote@LIGO.ORG - 10:44, Friday 06 June 2025 (84862)

I added GDS CALIB to this plot from the same time.

Images attached to this comment
H1 ISC
matthewrichard.todd@LIGO.ORG - posted 17:42, Wednesday 04 June 2025 - last comment - 11:09, Thursday 05 June 2025(84809)
IMC refl-trans-wfs comparisons before and after vent

M. Todd, C. Cahillane, G. Mansell


We're curious if any of the IMC WFS channels (DC and RF) are seeing some of the peaks we witness in DARM. Most of the sensors seem dominated by phase noise due to being in air; IMC-TRANS seems the best witness. Not sure if there is anything meaningfull from these, indicating coherence with the DARM peaks.

List of Figures: references are from March 12th, 2025 -- lives are from June 4th, 2025

1. IMC REFL and TRANS PSD estimate comparison before (March 12, 2025) and after vent (June 4, 2025)
2. IMC WFS A/B DC/RF-I PITCH
3. IMC WFS A/B DC/RF-I YAW

 

The template to measure these again is found at /ligo/home/matthewrichard.todd/Templates/imc/imc_wfs_comparison.xml

Images attached to this report
Comments related to this report
craig.cahillane@LIGO.ORG - 11:09, Thursday 05 June 2025 (84816)
It seems like the summary of this is "input beam jitter was never good, but is worse now than in March 2025", especially at 500 Hz in IMC_REFL and IMC_WFS_DC.

H1 SQZ
camilla.compton@LIGO.ORG - posted 17:06, Wednesday 04 June 2025 - last comment - 13:42, Thursday 05 June 2025(84794)
SQZ FIS SRC Detuning Dataset

Vicky, Sheila, Kevin, Camilla

Followed plan outlined in 84762 apart from after each SRCL offset change we moved sqz angle roughly close to max sqz to allow SCAN_SQZANG_KHZ enough range to optimize sqz.
After each 3 minutes of data, Kevin and Vicky took a ADF scan.

Increased NLG (needed to adjust SHG waveplate) by taking OPO trans setpoint from 95uW up to 120uW. Measured NLG = 49 (numbers below) following 76542.

Sheila's fitting found that the SRCL  offset (H1:LSC-SRCL1_OFFSET) needed to get a zero degree SRC detuning is -455 counts. Have not accepted in sdf, Sheila added to ISC_LOCK.
Finally we went to FDS and adjusted FC detuning from -34 to -24.

Data attached and saved at /ligo/home/camilla.compton/Documents/sqz/templates/dtt/20250607_SRCdetuning.xml

Type Time (UTC) SRCL Angle DTT Ref
No SQZ 21:37:00 - 21:43:00 N/A N/A ref 0
FIS 22:17:30 - 22:30:30 -191 (CLF-) 242 ref1
FIS 22:35:00 - 22:38:00 -90 (CLF+) 120 ref2
FIS 22:49:30 - 22:52:30 0 (CLF+) 172 ref3
FIS 23:17:00 - 23:20:00 -390 (CLF-) 161 ref4
FIS 23:45:00 - 23:48:00 -455 (CLF-) 143 ref5
FDS ~ 00:00:30 -455 (CLF-) 143 ref6

Note that I left the OPO servo gain at -8, but we have previously left it there (83569) or used -12dB for 120uW OPO trans (83370)

opo_grTrans_ setpoint_uW Amplified Max Amplified Min UnAmp Dark NLG (usual) OPO Gain
120 0.018035 0.000119507 0.000316548 -2e-5 48.9 -8
Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 13:42, Thursday 05 June 2025 (84806)

Here are the plots of this dataset, showing that our SRCL detuning (in gwinc) would be 50 mrad with no digital offset in the SRCL loop.  Kevin tells us that this is a double passed SRCL detuning, so it's really 25 mrad, 1.4 degrees of SRCL detuning. 

Edited to add the last point (and have the correct plots).

Images attached to this comment
H1 ISC
elenna.capote@LIGO.ORG - posted 19:34, Tuesday 03 June 2025 - last comment - 13:51, Thursday 05 June 2025(84778)
ASC Problems may be related to bad DC centering loops

Oli, Georgia, Elenna

While we were taking care of several LSC items, Georgia pointed out that we are seeing the 0.8 Hz buzzing in INP1 yaw again, and to a lesser degree CHARD Y. While we did several useless things to debug, I noticed that the DC centering loops were also buzzing with the same frequency oscillation. I decided to try changing the DC centering loop gain (since I had raised the loop gain significantly last week), and noticed that NONE of the DC6 pitch or yaw filters were engaged, but a gain of 1 was engaged, essentially feeding the input signal right back to PM1. Bad!!

Searchingh DC6 in the guardian shows that in PREP_ASC_FOR_FULL_IFO, I found these lines of code:

ezca.get_LIGOFilter('ASC-DC6_P').only_on('INPUT','OUTPUT','DECIMATION')
ezca.get_LIGOFilter('ASC-DC6_Y').only_on('INPUT','OUTPUT','DECIMATION')

Not good! Since the gain of DC6 is set on, this effectively keeps the gain on but turns off all the filters and just feeds back the pure error signal to the suspension.

I commented those lines out of the guardian and loaded, and then reengaged all the proper filters. A large 28 Hz line that had been present in DARM disappeared at this point, likely because the DC centering loops require a 28 Hz notch to avoid some suspension mode.

After this, I then tried turning down the DC1 and DC2 pitch and yaw gains to -1. This seemed to help the buzzing in CHARD and INP1. Georgia and I were able to engage all the low noise ASC settings without any issues (CHARD P had been held in high bandwidth to avoid a ring up and the soft loops had high gain for the same reason).

We need to monitor for a while longer and also try relocking, but these changes may fix many of our ASC issues.

I have SDFed these gain changes.

Comments related to this report
georgia.mansell@LIGO.ORG - 23:30, Tuesday 03 June 2025 (84785)

While locking this arvo, we stepped through lownoise_asc slowly by hand trying to catch which step was causing the 1Hz ring up that caused locklosses yesterday.

One time we reduced the DSOFT_Y gain down, thought we saw something ring up, but when we gradually decreased it the ring up did not come back.

The CHARD_P filter and gain changes in this state seemed to cause some oscillations in the PRG, so we left CHARD_P in a high noise state for a while. This left a lot of noise in DARM (first screenshot). We later ran the lownoise_asc steps for CHARD_P, after Craig and pals phased the LSC-POP diode, and this seemed to fine (second screenshot).

Hopefully the reduced gain in DC1 and 2 and the existance of filters in the DC6 loops will improve the ASC. But if we still see ringups in lownoise_asc the next best thing to try is undoing the steps for CHARD_P.

Images attached to this comment
elenna.capote@LIGO.ORG - 13:27, Wednesday 04 June 2025 (84793)

We now have confirmation that the DC centering loops have been having a significant effect on the ASC and causing many of our problems.

The DC loops appeared to have a large amount of gain peaking at low power around 0.8 Hz (I turned up the gain too high and didn't check the gain peaking). After we powered up I measured CHARD Y, which is a loop whose gain we have not been able to raise until reaching high power during the past few days. Attached is a comparison of the CHARD Y OLG both with the DC centering loop gain high and low (cut by half).

We were able to turn up and turn down the DC centering gain to confirm that it is causing the right half plane zero in CHARD Y. We only measured CHARD Y so we don't know the effect on other loops, but it appears that other loops are also more stable with less gain in the DC centering.

Images attached to this comment
elenna.capote@LIGO.ORG - 13:51, Thursday 05 June 2025 (84822)

I have turned up the CHARD Y gain at engage ASC with no problems, this is now saved in the guardian.

Displaying reports 6681-6700 of 89075.Go to page Start 331 332 333 334 335 336 337 338 339 End