Sudarshan, Jim and Dave
We power cycled h1iscey as part of the investigation to fix some dodgy ADC channels, we were not successful.
sequence:
take h1iscey out of dolphin, stop models, power down CPU, power down IOChassis, power down PEM AA chassis.
power up AA, power up IOChassis, power up CPU.
Sudarshan, Gabriele
To try to reduce as much as possible the beam pointing sensitivity of the ISS photodiodes, we wrote a python script that reads the PD signals and demodulate them with the excitation sent to IM3. In this way we could send a 12 Hz, 1000 cts sinusoid in yaw and a 17 Hz, 1000 counts sinusoid in pitch, and look at time domain traces of the demodulated signals, as shown in the first attached plot. We moved a bit the picomotors, and we could improve quite a lot the situation. As shown in the second plot, right now we almost can't see the sinusoids in the PD signals, since they're below the noise background. Here are therefore upper limtis on the dP/P/dx:
Photodiode | Pitch [1/m] | Yaw [1/m] |
PD5 | 18 | 105 |
PD6 | 18 | 64 |
PD7 | 20 | 107 |
PD8 | 21 | 79 |
The optimal position we found is not exactly with the QPD centered (both x and y are around 0.3). Maybe we could improve this, but for the moment we guess the situation is good enough.
Per the weekly Tues Maintenance task, the chiller was topped off to the MAX level mark (needed ~250ml to do this). The stopper for the Chiller isn't ideal (seems a bit big and sheds a bit to make it seat in the inlet). Last time the chiller was filled was on 9/15/14.
I measured the beam pointing sensitivity of all the eight ISS second loop diodes. The naming is the one corresponding to the new slow channel acquisition, we'll check tomorrow the correspondence to the PD1-8 signals. For some diodes, in pitch, I was not able to see any significant modulation
Channel | dP/P/x [1/m] PITCH | dP/P/x [1/m] YAW |
CH24 - PD1 | - | 560 |
CH25 - PD2 | 140 | 910 |
CH26 - PD3 | 170 | 340 |
CH27 - PD4 | - | 150 |
CH28 - PD5 | - | 370 |
CH29 - PD6 | 220 | 1610 |
CH30 - PD7 | 780 | 520 |
CH31 - PD8 | 270 | 540 |
For those not familiar with the meaning of these numbers, the typical values measured for the ISS array before installation were between 1 and 30, depending on the array and on the diode. So the numbers I got are in general quite large.
This beam position on the PD is maybe not the best one, since we are not at the maximum power for all the diodes simultaneously. For each diode, it is possibile to find a beam position that gives maximum power. This also corresponds to undetectable coupling of beam motion to dP/P (at least at this level of excitation). However, the good position is different for each diode, and the non optimal one can have a significant loss of power and large coupling of beam motion to dP/P. The table above is representative of what we normally get.
Here is the procedure in details
Comparable to other Level3s.
Weekly report of various things. There are daily spikes in the H1 chiller and diode room relative humidity. The spikes also occur in the chiller room temperature but not in the diode room, or at least the ones in the diode room are not as large.
Relative power noise looks nominal. Better than the reference measurement below 10 Hz and a factor of a few worse between 10 Hz and 4 kHz. The ISS was locked at the time with a diffracted power of ~9%, REFSIGNAL -2.03 V, and output DC of 10.01 V on PDA, 10.19 V on PDB. Gain slider on 10 dB. Frequency noise is better than the reference measurement above ~500 Hz, worse below. Otherwise the same as per previous weeks. Beam pointing looks nominal. All better than the reference measurement. Mode scan looks nominal. Higher order mode count slightly higher than last week, 55 cf. 56. Higher order mode power slightly higher too, 4.7% cf. 4.6%. Nothing to worry about. ISS relative power noise looks good. The out of loop measurement (PDB) is flat from 3 Hz to ~100 Hz, at ~1.3E-8. Rising to ~2E-8 at 1 kHz.
no restarts reported
Kiwamu, Jenne, Alexa, Sheila, Daniel,
Today we locked ALS COMM. We chaanged the locking sequence compared to our old sequence. One difference is that we have moved the notches in MC2 to M2, so we can have a higher crossover between the slow and fast actuators (CARM gain is 240 now, instead of 80). We also got rid of a z5 p20 filter we had in the CARM filter module. The rest is the same as it was in late May. This seems to be locking fairly robustly. The ugf is 1 kHz, with a phase of -80 deg. A measurement of the cross over is attached.
We also aligned the DIFF beatnote, 800mVpp. We have locked this at low gain a few times. We need to feedback to the top mass of the ETMs to keep the DIFF PLL within the VCO range, but we have had trouble engaging the tidal feed back.
[Jim, Fabrice]
To help comparing and finding the best of the blend configurations used at each sites, we loaded the LLO blend configuration on ITMY. Unlike for previous transfers of filters from site to site, we did not export the filters from LLO foton files into different continuous or digital forms before to re-convert them, simplify and re-install them into LHO foton file. We directly copied and pasted the second order sections from one foton file to another. [We used the filter file logged in the repository Keith has set up (very useful!): https://daqsvn.ligo-la.caltech.edu/websvn/]. A few blend filters take two banks, we left it that way.
We performed measurements with the initial configurations (called "before" in the figures) and with the LLO filters configuration (called "after" in the figures). The blend configurations are summarized at the end of the report.
- The first two figures show the ISI motion for each configuration. Using the LLO config (after), the X and Y motion is lower at the suspension resonances at the cost of more motion at higher frequencies (good compromise). The rotational motions appear higher at most frequencies.
- The next two figures show the suspension point motion for each configuration. In the initial configuration, the suspension point motion is dominated by ISI longitudinal motion at almost all frequencies. With the LLO blend, the RZ motion takes over around 1 Hz.
- The last two figures show the optical lever motion for each configuration. In this example the Pitch RMS motion went from 5.8 nRad (before) to 4.1 nRad (after). The Yaw RMS motion went from 6.6 nRad to 4.2 nRad. [These numbers seem very small (calibration issue?) but the relative comparison is probably fair.]
We leave it on for tonight for making a comparison over a longer stretch of time.
---------------
Blend configuration used for the "before" and 'after" measurements.
DOF: Before / After
Stage 1 X : Tbetter / 45mHz
Stage 1 Y: Tbetter / 45mHz
Stage 1 RZ: TCrappy / Off
Stage 1 Z: T750mHz / 90mHz
Stage 1 RX: Tbetter / [250a & 250b for CPS and T240, 250 for L4C]
Stage 1 RY: Tbetter / [250a & 250b for CPS and T240, 250 for L4C]
Stage 2 X : T750mHz / 250 mHz
Stage 2 Y: T750mHz / 250 mHz
Stage 2 RZ: T750mHz / Off
Stage 2 Z: T750mHz / Off
Stage 2 RX: T750mHz / Off
Stage 2 RY: T750mHz / Off
After finding good whitening setting, the arm was aligned, I walked the beam on WFSB to find a good offset.
Demod phase was set after finding a good position on WFSB (PIT offset = -0.15, YAW=0). For WFSA I never set any offset.
See the first attachment for the demod phase.
See the second for the spectra after an offset of -0.15 was set for the WFSB PIT centering servo to balance the demod signal peak generated by an excitation to the PDH board EXC A.
Sudarshan, Gabriele
We significantly improved the beam centering on the ISS array: now we have good powers on all diodes, centered QPD and lower coupling of beam motion to dP/P
After a lot of steps in the LEFT direction and few in the UP direction (for picomotor 8), we could get the beam centered on the QPD and good power levels on all diodes. Actually, we believe we are quite close to the maximum power for each diode.
The following table compares the power levels (in counts) before our adjustment and at the end.
Photodiode | Power before [cts.] | Power after [cts.] |
CH24 - PD1 | 460 | 470 |
CH25 - PD2 | 500 | 507 |
CH26 - PD3 | 510 | 505 |
CH27 - PD4 | 560 | 563 |
CH28 - PD5 | 535 | 554 |
CH29 - PD6 | 460 | 520 |
CH30 - PD7 | 550 | 612 |
CH31 - PD8 | 530 | 564 |
Then, we measured again the coupling of beam motion to dP/P, and we got much improved numbers:
Photodiode | dP/P/dx PITCH [1/m] | dP/P/dx YAW [1/m] |
CH24 - PD1 | < 30 | < 90 |
CH25 - PD2 | 130 | 430 |
CH26 - PD3 | < 30 | < 60 |
CH27 - PD4 | 40 | 180 |
CH28 - PD5 | 310 | 90 |
CH29 - PD6 | 60 | 100 |
CH30 - PD7 | < 45 | < 50 |
CH31 - PD8 | < 50 | < 50 |
At this level it is difficult to find a better position looking only at the power levels. We might have to optmize the centering looking directly at the beam motion coupling.
CH24 - CH 27 = PD1 - PD4 upper row, left to right CH28 - CH 31 = PD5 - PD8 lower row, left to right
Summary:
Some whitening settings for EY green WFSA I3, Q3 and WFSB Q2 channel don't work. It's probably the whitening chassis itself as the whitening request and the readback agree with each other.
For now I'm leaving both of the chassis in place as there are some usable settings, but note that these guys have a history of many troubles due to chassis and crappy cablings (12159, 12138, 12127).
Details 1:
For WFSA I3 and WFSB Q2, the measured whitening gain doesn't match the request and the readback (attached).
You can see that in both cases one of four stages (+3dB, +6dB, +12dB and +24dB) is failing. It's the 12dB gain stage for WFSA I3 and the 6dB stage for WFSB Q2.
These were measured injecting 20mVpp signal at 100Hz using a function generator and a breakout board.
Details 2:
For WFSA Q3, the third whitening filter doesn't turn on.
For now:
I set the gain to +27dB and turned all filters off.
Update: It was crappy connector shell.
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=14243
Alastair & Greg
Greg is running the TCS x-arm laser for a couple of hours (from 16:41 onwards) so we can start to get some data on stability at LHO. The beam to the CP is blocked so there is no output, and the laser is being run with the table closed.
Shut the laser off at 7:20pm. Rotation stage is non-functional right now, most likely due to the cable dressing that was done at the end of last week. Will try and restart the ethercat chassis during maintenance tomorrow.
Performance plots later. Lvl2 will be quick but later too.
Now with added "damped" plots. Note, the damping loops on the electronics test stand are hodge podge and so damping was poor for some regions of many loops. As well, like I mentioned in earlier logs, the coherence of this in-air QUAD is poor at lower frequencies. I spent some time trying to work out better excitation filtering/boosting but to no avail. Damping works on both M0 and R0 chains of Q6.
Attached below is a comparison of undamped and damped Phase 1b QUAD06 TFs, which are also compared to QUADs of similar construction. Summary: As already noted above, damping loops are in no way optimised on this test-stand, however, damping on all DOFs on both chains of QUAD06 can be observed. The most egregious damping behaviour occurs on the R DOF of the reaction chain. It should be noted that, since the undamped TF for this DOF appears clear, this indicates that issue is most likely filter configuration related when attempting to engage damping loops. Thus alleviating any concerns. All data, plots and scripts have been committed to the sus svn.
This morning I adjusted the x-arm alignment to obtain green locking. First I misaligned ETMX, and adjusted TMSX using the ITMX baffle PDs. See table below for configuration:
Old Average (alog 13741) |
Target PD1 | Target PD4 | new Average | |
TMSX (P,Y) | (-23.8, -320.1) | (-58.1, -292.7) | (9.6, -354.9) | (-24.25, -323.8) |
NOTE: he baffle PDs read 2.4V at 0dB gain.
Then, using the ETMX camera I centered the beam on ETMX by adjusting the ITMX alignment. I found ITMX (P,Y) = (74.7, -8.2). Finally, I maximized the flashes by aligning ETMX. H1:ALS-X-TR_A_LF_OUT reached about 0.85 cnts. With this alignment we were able to lock the green beam to the arm. The alignments are saved to the guardian.
The dither alignment in yaw helped bring the counts up to about 1. The pitch dither made things worse.
J. Kissel I was warned that -- though all the GND STS channels are mapped from the instrument to the frames correctly now (see LHO aLOG 14072) -- what actually gets fed into the sensor correction filter banks is a total mess in the corner station. I've scoured the front-end simulink models, toggled some switches at the racks in the EE bay, and stomped on the ground near the STSs themselves trying to map it out, and all I can say is WOW do I agree. I'll work with the SEI and CDS groups to clean up. Here're the facts, as they stand now, in order of my discovery: (1) In reality, we want the following seismometer-location-to-channel map for all 17 digital instances of the signals in the corner (6 HAM HPIs, 5 HAM ISIs, 3 BSC HPIs, 3 BSC HPIs): Just +X of HAM2 => STS A In the Beer Garden => STS B Just +Y of HAM5 => STS C as determined by D1002704, revised due to Integration Issue 45, and DCN E1400111. (2) I've confirmed that the above mapping is correct for ITMY (the "master" front-end model responsible for storing these STSs and "GND" channels in the frames) by performing my finest hill-billy hoe-down near the respective STS, and watching the ISI-GND channels on a CDS laptop. (3) Because of the STS-2 analog distribution chassis, and that the SEI BSC wiring diagram (D0901301), and SEI HAM wiring diagrams (D1101584, D1101576, and D1000298) were written before the ABC convention was established and not addressed in E1400111, there're 17-choose-3 = 680 possible combinations, and I'm pretty sure we used all of them. Front end models: (4) ALL HAM-ISIs use the library part, ${userapps}/release/isi/common/models/isihammaster.mdl. There is another library, isiham236master.mdl, that looks deceiving in the same directory, but it's unused according to the tar balls of source code for what's actually running on the IFO. This should be removed from the repo. (5a) The HAM-ISIs are reasonably consistent, in that, ADC_0 or ADC_2 Channels 24-26 => STS A XYZ ADC_0 or ADC_2 Channels 28-30 => STS B XYZ ADC_1 or ADC_3 Channels 24-26 => STS C XYZ where it's ADC_0/1 on the "first" HAM-ISI in the I/O chassis, and ADC_2/3 on the "second" HAM-ISI (HAM2, HAM4, and HAM6 are the "firsts," HAM3 and HAM5 are the "seconds."). (5b) EXCEPT HAM2, who has ADC_0 channels 24-26 mapped into BOTH STS A and STS B. (6) Because of an RCG "feature" even though different ADC *card* numbers are used between the seconds and firsts, the block name is always ADC 0 or ADC 1. (7) The HAM-HPIs all use the same library part, ${userapps}/release/hpi/common/models. (8a) HPIs HAM2-5 have GND STSs hooked up, also, reasonably consistent in that they all use ADC_0 or ADC_2 Channels 24-26 => STS A XYZ all piped into STS A, with STS B and STSC terminated. Again, the "firsts" use ADC0, and the "seconds" use ADC 2. (8b) EXCEPT HAMs 1 & 6 have all STS inputs terminated. (9) The BSC ISIs and the BSC-HEPIs are consistent, but consistently bonkers. BSC1 ITMY ADC_3 23-25 => STS A 26-28 => STS B 29-31 => STS C BSC2 BS ADC_3 29-31 => STS A 23-25 => STS B 26-28 => STS C BSC3 ITMX ADC_3 26-28 => STS A 29-31 => STS B 23-25 => STS C That's right -- the channels have been cyclically rotated between BSC chambers. Electronics Chain: To test out which STS chassis maps to which GNDSTSINF (for ISIs) or STSINF (for HPIs), just in case the STS distribution chassis had been used to rectify the front-end badness, I toggled the period switch on the front of each of the three chassis, in consecutive order, and followed which channels showed the characteristic flip to (more) AC coupled signal (1 [sec] period) and then drove off into tilt land after switching back to the low-frequency mode (120 [sec] period). Since I didn't want to disconnect any cables, and couldn't simultaneously look at all the channels needed with the tiny laptop while zydeco dancing, all I could determine which which *rack* affected which GNDSTSINf or STSINF channel. (10) BSC 1 (ITMY) ISI and HPI on-board sensors are read out in rack SEI-C4, BSC2 (BS) ISI and HPI are read out in rack SEI-C5, and BSC3 (ITMX) ISI and HPI are read out by rack SEI-C6. As such, I'll refer to the STS chassis that I switch as C4, C5, and C6, after the rack in which they're mounted, since I was unable to determine which was HAM2 (STS A), Beer Garden (STS B), or HAM5 (STS C). (11) For the BSC-ISIs, the matrix of channels affected by the switching is as follows: ITMY BS ITMX C4 A A A C5 B B B C6 (bonkers) C C This indicates that, even though the ADC to model mapping is some crazy, cyclic thing, the cables from the STS distribution chassis have been arranged such that what goes into the ADC is "normal." The ITMY STS C channel doesn't make any sense to me. It didn't respond to any of the period-switch toggles, but still showed live tilt-full signals. Need to debug that one. (12) For the BSC-HPIs, it's different: ITMY BS ITMX C4 A B C C5 B C A C6 C A B This indicates, that the cabling matches the crazy-bonkers front-end mapping. (13) For the HAM-ISIs, it's different: HAM2 HAM3 HAM4 HAM5 HAM6 C4 A&B A (dead) (dead) A C5 (no change) B (dead) (dead) B C6 C C (dead) (dead) (no change) HAM2 is weird, but is consistent with the model layout described in (5b). HAMs 4 and 5 are receiving only ADC noise -- maybe this means the channels aren't hooked up? I didn't check. (14) And finally, the HAM-HEPIs, they're the worst off: HAM1 HAM2 HAM3 HAM4 HAM5 HAM6 C4 (n/c) A B (dead) (dead) (n/c) C5 (n/c) (n/c) (n/c) (n/c) (n/c) (n/c) C6 (n/c) (n/c) (n/c) (n/c) (n/c) (n/c) where "n/c" is not connected in the front-end model as described in (7a). Still no help as to why HAM4 and HAM5 are reading out ADC noise. And that's the anti-climactic end of the list. We've got some work to do! Step-one will be to update the SEI wiring diagrams to clearly define how each STS gets into each front-end via an ADC channel list. Next, change the top-level front end models to match the convention in the drawings. Third, change the cabling at the racks around so we get the expected behavior. At the moment, although it's don't in an icky way, the BSC-ISIs are our best case.
B. Abbott, J. Kissel Sorry for the belated post on this: I got a reply from B. Abbott on this, that is detailed enough that it should be put here for future reference. -------- Ben's reply --------- Looking at D0901301,, page 11 some things can be seen: In answer to item (12), i.e.: ITMY BS ITMX C4 A B C C5 B C A C6 C A B This is actually necessary, and had been planned as such. Each of the corner-station STS2s (HAM2, ITMY, and HAM5) are actually read out by the BSC chamber racks, i.e. the ITMX, BS, and ITMY chamber racks. These are the analog "home" where the STS is read out. Because the "Home" BSC chamber for each STS wants to bring in both the XYZ channels, and the UVW channels, the XYZ channels must come in to the local AA chassis on channels 23, 24 and 25, respectively (starting at channel 00, of course). That leaves the next STS-2 in the sequence to go into Ch26-28, and the next one to go into 29-31. This may not be optimal for ease of model-making, but it is necessitated by the desire for all six signals (which necessitates a 15-pin DSub cable). Looking at D1101576, Page 3, we see the HAM 2 (HAM3) mapping is: STS A on ADC0 (ADC2) Chs 24-27, STS B on ADC1 (ADC3) Chs 24-27, and STS C on ADC0 (ADC2) Chs 28-31. In D1000298, page 4, we see the analogous wiring to HAMs 2&3: the HAM 4 (HAM5) mapping is: STS A on ADC0 (ADC2) Chs 24-27, STS B on ADC1 (ADC3) Chs 24-27, and STS C on ADC0 (ADC2) Chs 28-31. Suggestions: (a) I like the way that HAMs 1&6 are hooked up, and suggest that we move all of the cables to match that mapping, with STS A coming in on ADC0 (or ADC2) Chs 24-27, STS B on ADC1 (or ADC3) Chs 24-27 and STS C on ADC1 (or ADC3) Chs 28-31. (b) I don't see any way to change the BSC mapping in the corner by moving cables, unless we fundamentally change the kind of cable (make a 15-9 pin converter) and don't care about the UVW channels. (c) I don't think there's much of any way to help out with the HEPI channels in hardware. I think this is solely a simulink model thing. ---------- End Ben's reply My thoughts on (a) and (c): I still have to do some research and talk with LLO on this. After conversing with Ryan DeRosa, he says "we have a functional system here!", so I want to make sure we don't re-invent the wheel and start another new convention before we write stuff down and change anything here at LHO. Regarding (b), fair enough. I had just forgotten about the need. But we at least need to make sure its consistent everywhere!