Reports until 12:48, Wednesday 19 February 2014
H1 PSL (PSL)
corey.gray@LIGO.ORG - posted 12:48, Wednesday 19 February 2014 (10177)
H1 PSL Operator Check

Laser Status:

PMC:

FSS:

ISS:

Non-image files attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 12:33, Wednesday 19 February 2014 (10178)
ITMX 120[.4]Hz peak

So I took spectra of this, saved some references, controlled down Stage2, brought it back up to the same state and the peak was gone.  However, after a short time the peak started growing.  Starting out at the Isolation boosts, I found that by disabling the boosts on the X & RY dofs, the peak reversed and started shrinking.  It went down but there may be more dofs where this is coming in or the disturbance may come & go or grow and shrink because now I see the peak going up and then dropping down.  The first plot shows the full peak  (refs) and the currents are with the boosts disabled.  The PEM MAG channel is also shown.

Fabrice suggests we likely have a broad area of marginal stability and this feature which doesn't look like the Main 60Hz harmonic according too Robert (looking at Mag channels) is just a symptom.  It could be a DC motor that has locked here and maybe restarting a few things and it may go away but we need to fix the marginal stability if we can confirm it.  We will run a TF when able to look at the MIMO loop and go from there.

Images attached to this report
H1 ISC (ISC)
evan.hall@LIGO.ORG - posted 11:29, Wednesday 19 February 2014 (10176)
Antiwhitening filters for LSC PDs

I have added three stages of 1:0 antiwhitening filters for LSC_POP_A_RF9 I and Q and LSC_REFL_A_RF45 I and Q.

The following now all have three such 1:0 filters:

H1 SEI (CDS)
hugh.radkins@LIGO.ORG - posted 10:04, Wednesday 19 February 2014 - last comment - 10:15, Wednesday 19 February 2014(10172)
Using Dataviewer for frequency analysis--Beware

Not that this can't be operator error but see attached.  Jim noticed a large output from the ITMX Stage2.  1000s of counts is of concern; 100s is normal.  Anyway, looking at dataviewer of the fast channels, I thought this was ~8Hz; but the spectum  and the DTT time series says this is 120Hz.  Still looking for this peak source.

Images attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 10:15, Wednesday 19 February 2014 (10174)

OK Robert solved my problem--The Dataviewer by default comes up at 128 hz resolution and this 120Hz peak is very large.  When I go to a higher 'resolution' in dataviewer it looks correct.  User beware.

H1 ISC
kiwamu.izumi@LIGO.ORG - posted 07:42, Wednesday 19 February 2014 (10168)
done with the morning red lock

I am done with the morning red locking.

Status of the interferometer:

 

PRMI doesn't lock

I have no luck for locking the PRMI this morning -- I was never able to catch a fringe even for a short period of time for some reason. The alignment seemed OK because I could see a build up of about 10000 counts at maximum in POPAIR_B_RF18_I_ERR. I only tried the demod phase of 133 deg in REFLAIR_45. I didn't try to change the LSC gains at all because I ran out the time. Also, all the settings were once set by Stefan's old script, setPRMI, instead of guardian's up-script and then I changed the MICH and PRCL gains to be 40 and -0.4 respectively.

H1 ISC
sheila.dwyer@LIGO.ORG - posted 07:36, Wednesday 19 February 2014 (10167)
Arm modulation frequency
After finding that we weren't able to stably lock the arm cavity with the half Anderson modulation frequency, we switched it back to the rf source 24.407079MHz. I used the 4392A to confirm that there is about 0.1 dBm going to the eom
H1 ISC
kiwamu.izumi@LIGO.ORG - posted 05:54, Wednesday 19 February 2014 (10165)
PRMI guardian not accessible

Help me, Jamie! I want to use LSC_PRMIsb! crying

H1 SEI (ISC)
kiwamu.izumi@LIGO.ORG - posted 05:41, Wednesday 19 February 2014 (10164)
HAM3 ISI is back to business

HAM3 ISI was found to be down. So I brought it up with the level 3 isolation as noted by Hugo (alog 10114). According to its watchdog medm screen, it tripped because the payload had tripped at 1076806396 (which corresponds to Feb 19 2014 00:53:00 UTC).

H1 ISC (SUS)
kiwamu.izumi@LIGO.ORG - posted 05:27, Wednesday 19 February 2014 - last comment - 07:23, Wednesday 19 February 2014(10163)
ETMX intentionally misaligned

Until the blue team starts working on the WFS.

Also, I disabled the oplev damping loop to avoid unnecessary kick because the oplev beam is almost off from its QPD. I did the following commands:

ezcaswitch  H1:SUS-ETMX_L2_OLDAMP_Y OUTPUT OFF

ezcaswitch  H1:SUS-ETMX_L2_OLDAMP_P OUTPUT OFF

Comments related to this report
kiwamu.izumi@LIGO.ORG - 07:23, Wednesday 19 February 2014 (10166)

ETMX is back aligned for Keita and Jax who will do some EX WFS business. The oplev loops are also activated again.

H1 ISC (SUS)
kiwamu.izumi@LIGO.ORG - posted 05:20, Wednesday 19 February 2014 (10162)
feedback left on PRM and PR2

I found that the LSC feedback was left on for the PRLC servo. This kept kicking PRM and PR2 without locking anything. Bad. I disabled it for now.

H1 SEI
sheila.dwyer@LIGO.ORG - posted 17:01, Tuesday 18 February 2014 - last comment - 08:03, Wednesday 19 February 2014(10160)
ITMX ISI

for some reason the ITMX ISI was using 750 blends, although Hugho left it on Tcrappy friday night (10114) and Hugh checked that things were OK this morning (10122.)

I moved it to Tcrappy on both stages

Comments related to this report
hugh.radkins@LIGO.ORG - 08:03, Wednesday 19 February 2014 (10169)

I was in a hurry; Jim was at the end station and sorely needed my assistance.  Anyway, despite several attempts, I was unable to transition either ITM to lower blends with the trilliums.  Oddly, the BS went fairly easily...

H1 ISC
sheila.dwyer@LIGO.ORG - posted 16:45, Tuesday 18 February 2014 (10158)
end x PLL beat note realinged

The IR path on ISCEX must have gotten misalinged, I tuned up the beat note and now we have -13.5dBm reported by the PFD. 

H1 ISC (ISC)
evan.hall@LIGO.ORG - posted 15:56, Tuesday 18 February 2014 - last comment - 17:22, Tuesday 18 February 2014(10155)
REFLAIR_A_RF45_Q_ERR RFAM

I misaligned the BS and ITMX and looked at the trended time series of REFLAIR_A_RF45_Q_ERR. Since the beam is (in theory) bouncing prompty off the PRM and onto the diode without any kind of Fabry-Perot interference, this signal should tell us something about 45 MHz RFAM.

The calibration (7.6 cts / nm) is from elog 10127.

Non-image files attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 17:22, Tuesday 18 February 2014 (10161)ISC

As Kiwamu pointed out, the calibration must be multiplied by R_PRM / T_PRM^2, since the PD experiences the reflection of PRM rather than the doubly-transmitted beam. The plot is now corrected.

H1 ISC
keita.kawabe@LIGO.ORG - posted 15:26, Tuesday 18 February 2014 - last comment - 10:04, Wednesday 19 February 2014(10147)
ALSX WFS RF check (Yuta, Jax, Keita)

We used AM laser to check up the ALSX WFS.

AM laser output: 1.8mW (measured with old ophir power meter, 978nm, filterr out)

Modulation source was set to 0.1vpp 24.389310MHz (this frequency was set before fixing the 1.002MHz that was mentioned in another alog).

WFS DC interface was set to low DC gain mode and the DC offset zero-ed.

Demod whitening gain was 21dB, first and the second whitening filter were on and the third off, a-whites were turned on though I don't know if they're put in yet (turns out that the awhites were not yet there when we did this measurement, so the "demod" numbers in the table below are 33dB higher than they should be.).

 
This produced the following outputs from WFSA and WFSB:
  WFSA DC WFSA demod (both I and Q) WFSB DC WFSB demod (both I and Q)
SEG1 3000 cts +-20k cts 2600 +-19k
SEG2 3070 +-20k 2900 +-9k
SEG3 2395 +-12k 2740 +-20k
SEG4 2930 +-18k 2960 +-20k

Seems like the demod signal out of WFSA SEG3 and WFSB SEG2 are both about a factor of 2 smaller than the others. On the scope it seemed that the RF signal coming from the WFS head was already small for these segments.

We confirmed that the whitening gain and filters are working.

Comments related to this report
keita.kawabe@LIGO.ORG - 15:28, Tuesday 18 February 2014 (10153)

Jax found that depending on how the cables were strained on the AM laser the amplitude of AM varies greatly (from nothingness to full). Crappy RF connection?

kiwamu.izumi@LIGO.ORG - 16:53, Tuesday 18 February 2014 (10159)

I didn't see such an effect when I used it at ISCT1 a month ago and the AM power was reproducable. This could be a new issue.

jaclyn.sanders@LIGO.ORG - 10:04, Wednesday 19 February 2014 (10173)

There may have been a miscommunication between me and Keita. When the cables were strained, they applied a torque to the laser, twisting it out of alignment with the WFS aperture (maybe 45 degrees rather than head-on? didn't exactly measure it, just corrected it.) So the power level issues were caused by cable strain, but on a purely mechanical level.

H1 SUS
thomas.vo@LIGO.ORG - posted 13:28, Tuesday 18 February 2014 - last comment - 16:29, Tuesday 18 February 2014(10146)
Arnaud at HAM4 @ 1:28 PM PT
Working on unlocking SR2 suspension. 
Comments related to this report
arnaud.pele@LIGO.ORG - 16:29, Tuesday 18 February 2014 (10154)

Andres and I are done. We unlocked the suspension, which seems to be free when looking at the L to L TF.

H1 ISC (ISC)
evan.hall@LIGO.ORG - posted 08:35, Tuesday 18 February 2014 - last comment - 15:17, Wednesday 19 February 2014(10127)
Michelson lock adjustments and measurements

[Yuta, Rana, Evan]

When Stefan left Friday evening, PRMI wouldn't lock. We poked around at MEDM screens for a while before deciding that a more systematic diagnosis was in order. We decided to attack just the Michelson first.

We parked PRM and misaligned ETMX. We then adjusted the LSC MICH filter bank to duplicate was was done for Kiwamu's and Yuta's previous Michelson lock characterization (elog 9698, 31 Jan 2014). Even with a 1:0 integrator engaged, we found that the Michelson would not lock for more than 30 s, and the error signal drifted by about a third of its peak-to-peak.

We were able to measure the OLTF, and found that it had a UGF of 3 Hz with no phase margin. Rana suggested we notch out the bounce mode of the BS suspension with filters from LLO. We got the filter, adjusted the frequency to the LHO BS (17.8 Hz, as measured from the REFLAIR_A_RF45_Q_ERR spectrum), and then added it to FM6 on LSC_MICH. After doing this, we found that the Michelson lock is much more stable --- it appears to lock indefinitely.

In order to calibrate REFLAIR_A_RF45_Q_ERR in terms of mirror motion, we let the Michelson swing freely and recorded the fringing. We know that the fringing amplitude (in counts) as a function of asymmetry l is A sin(4 pi l / lambda), so the linear portion has a slope of A * 4 pi / lambda, in counts per m. I took the swinging data, trended the minimum, median, and maximum, and then took the median of the trended minimum and maximum values. A histogram of these values is attached. From this I find A = 643 counts; this gives the conversion factor as 7.6 counts per nanometer.

We used this value to get a calibrated spectrum of the dark noise of REFLAIR_A_RF45_Q_ERR, which we measured with the modecleaner unlocked. A trended 10-minute time series is attached; we see that the drift is on the order of a few nanometers over this time period. Also attached is a spectrum of the dark noise, along with Yuta's estimate of the control signal (LSC_MICH_OUT) the Michelson, given in terms of length. The estimated length noise was 1.1 um RMS.

An OLTF of the improved Michelson loop is attached. The UGF is now 7.5 Hz, with a phase margin of 20 degrees. Also attached is Yuta's model of the expected OLTF; the agreeement is excellent around the UGF, except for the flat gain. This model uses already existing an already of the triple suspension of the BS (/ligo/svncommon/SusSVN/sus/trunk/Common/MatlabTools/TripleModel_Production).

We assumed that the suspension model gives BS actuation efficiency from H1:SUS-BS_M2_LOCK_L_OUTPUT to the actual M3 motion in m/counts. However, there is a missing factor of 1.7e-3 in this actuation efficiency to fit to the measured OLTF.

Images attached to this report
Non-image files attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 13:05, Wednesday 19 February 2014 (10175)

Written by Yuta

I found that I forgot to put 0.05 in my OLTF model (I forgot that the output matrix H1:LSC-OUTPUT_MTRX for MICH to BS was set to 0.05). I also forgot to put sqrt(2) to convert BS motion to MICH length change. I updated the OLTF figure, and now, the missing factor is 0.024.

Images attached to this comment
evan.hall@LIGO.ORG - 15:17, Wednesday 19 February 2014 (10188)

Written by Yuta

The missing factor 0.024 was from the conversion factor in uN/counts.
I assumed that the suspension model I use gives me the transfer function in m/counts, but it was actually in m/uN.
The conversion factor can be calculated using the parameters in G1100968 (for BS specific, see T1100479);

0.963 N/A * 0.32 mA/V * 20.0/2**18 V/counts = 2.35e-8 N/counts = 0.024 uN/counts

The OLTF now agrees well with the expected. Thanks to Jeff K. and Arnaud!
(But still, there is a missing factor in the PD signal chain. The measured value 7.6 counts/nm is used in this expected curve. See alog #9630 and #9857)

Note that this factor(uN/counts) is also missing in the current noise budget model which lives in /ligo/svncommon/NbSVN/aligonoisebudget/trunk/PRMI.

Displaying reports 73381-73400 of 83254.Go to page Start 3666 3667 3668 3669 3670 3671 3672 3673 3674 End