Reports until 17:26, Thursday 10 April 2014
H1 ISC
gerardo.moreno@LIGO.ORG - posted 17:26, Thursday 10 April 2014 (11276)
ALS Shutter Replacement

(Joseph D., John W., Justin B., Sheila D.,  and Gerardo M.)

Attempted to install new ALS shutter, but as soon as we started we found 3 scratches on the viewport (inside side), see photo, John was consulted and the decision was to abort the rest of process, first contact was not applied to viewport, and the rest of the components were staged to finish work tomorrow.  GV7 will remain soft closed until then.

Images attached to this report
H1 SEI
sheila.dwyer@LIGO.ORG - posted 16:51, Thursday 10 April 2014 (11274)
ITMY trips

ITMY tripped twice while we were switching blends, guardian brought it back fine

H1 CDS (PEM)
david.barker@LIGO.ORG - posted 16:33, Thursday 10 April 2014 (11273)
overview pem medm for front end fast channels

I have built overview MEDM screens showing the EPICS monitor of all PEM fast channels. To add these for CS, EX and EY to the sitemap I had to give PEM two related pull downs. All weather screens are in the right pull down, dust and others in the left.

Currently the BLRMS signals are missing because they have different name suffixes, I'm in the process of adding them.

LHO General
gerardo.moreno@LIGO.ORG - posted 16:20, Thursday 10 April 2014 - last comment - 17:00, Thursday 10 April 2014(11272)
Operator Summary

- 9:00 am, Apollo to LVEA, prep for beer garden transformation.
- 9:15 am, David to LVEA, check on TCS cable short.---> done by 10:05 am.
- 9:30 am, Aaron to LVEA, cable run for photodiode amplifier.
- 9:41 am, Betsy and Travis to Y-End, SUS hardware retrieval.
- 10:14 am, Pablo to LVEA, hunt for a spare VCO.
- 11:30 am, Robert and guests to LVEA beer garden, installation of microphone.
- 1:00 pm, Kyle to Y-arm, open gate valves, not GV18.
- 1:10 pm, Karen to Y-End, cleaning.
- 1:10 pm, Corey and Cyrus to YBM, gigE camera testing.---> done by 1:35 pm.
- 2:00 pm, Apollo crew to LVEA, setup to move items around beer garden, remove stairs, support platforms, etc.
- 2:54 pm, Sheila and Justin to H1PSL laser enclosure, block ALS path for change of shutter.
- 3:15 pm, Joe and Gerardo to LVEA, remove and replace ALS path shutter.
- 3:24 pm, David and Greg to LVEA, TCS plumbing work.
- 3:49 pm, LVEA transitioning to laser safe.

Comments related to this report
gerardo.moreno@LIGO.ORG - 17:00, Thursday 10 April 2014 (11275)

GV7 was soft closed for ALS shutter work.

LHO VE
john.worden@LIGO.ORG - posted 15:49, Thursday 10 April 2014 (11270)
Y2 Accumulation RGA data

2 days of RGA accumulation data for Y2 Beam Tube.

Files attached are;

Y2accum.txt - time vs ion current

04102014_y2_accumulation.txt - as written by RGA software.

Y2accumCC.txt - Cold cathode PT246

 

Termperature data yet to come but it has been 80F in the afternoons lately.

 

The volume under test includes CP4 and CP7 at either end of the two kilometers. GV 18 and GV11 were hard closed for the duration.

Images attached to this report
Non-image files attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 15:27, Thursday 10 April 2014 (11271)
Opened GV6 and GV11 -> Valved-in IP11
Preparations for opening the Corner Station to the Y-end for a few hours tomorrow 

Note: Indicated IP11 alarm is the result of incorrect signal conversion values to CDS -> Actual voltages and currents are nominal for pressure conditions 
H1 AOS
daniel.sigg@LIGO.ORG - posted 12:01, Thursday 10 April 2014 - last comment - 07:51, Friday 11 April 2014(11269)
ITMY AOS baffle PD

(Filiberto, Aaron, Thomas, Daniel)

We installed the baffle PD amplifiers for ITMY. This is a new double chassis, so we replaced the old single unit. This should also fix channel 4 for the ITMX diodes. Previously, channel 4 was connected to channel 3, but now is back on channel 4. The TwinCAT system has been reconfigured to recognize the new channels.

Comments related to this report
daniel.sigg@LIGO.ORG - 07:51, Friday 11 April 2014 (11282)

Activated the ETMY baffled diode amplifier in TwinCAT.

LHO FMCS
mark.lubinski@LIGO.ORG - posted 11:53, Thursday 10 April 2014 (11268)
Fans switched at Y end
I switched from fan 1 to fan 2 at Y end
Fan 2 on at 11:39
Fan 1 off at 11:40
Fan 2 set to 12K flow 
H1 ISC
sheila.dwyer@LIGO.ORG - posted 11:05, Thursday 10 April 2014 - last comment - 12:07, Thursday 10 April 2014(11263)
ITMX also tripped earlier

ITMX has tripped twice this morning, no known cause for the first trip, the second one we caused.

Comments related to this report
sheila.dwyer@LIGO.ORG - 11:29, Thursday 10 April 2014 (11266)

ITMX and ITMY both tripped in the last few minutes.  Jim is recovereing.  Phil and Aaron are pulling cables, these might be a good example of times when overly sensitive watchdogs make it difficult to commision while there is normal install activity in the LVEA. 

sheila.dwyer@LIGO.ORG - 12:07, Thursday 10 April 2014 (11267)

Jim, Rich, Sheila,

several more trips, BS, both ITMs. 

Rich and I tried to put ITMX into a safe state:

GS13 and L4Cs in low gain mode, all blends on Start, raise T240 watchdog threshold, Sensor correction off.

After we heard that Fil and Aaron are out of the LVEA I tried switching back to the good performance state, it trippped again while I was switching blends.

Why do these trip while switching blends?  According to Rich that shouldn't happen, but it does.  The second attached plot below is the actuator trip that happened while I was switching blends. 

Images attached to this comment
H1 TCS
david.hosken@LIGO.ORG - posted 10:26, Thursday 10 April 2014 - last comment - 17:29, Thursday 10 April 2014(11262)
TCS status
Dave H, Alastair, Thomas, Greg

Quick summary of progress:

TCSX:
Laser was operated for a few hours on Monday with an output power of ~58.5W. Optics have been mounted and placed in position on the table. This table is now ready for alignment.

TCSY:
Optics/mounts have been staged, and are ready for table installation. Cabling is almost complete. Attempts were made on Wednesday to operate the laser/test the output power, however this was unable to be performed due to a fault with the paddlewheel flow meter (amongst other interlock/laser controller issues that are still to be tracked down). Some additional cabling is still to be installed. 

TCSX/Y periscopes have been partially assembled, still to track down one last component. Socket head cap screws with lower profile heads have been ordered, as it was observed that the cap screws for the periscope base sit proud. 
Comments related to this report
david.hosken@LIGO.ORG - 11:17, Thursday 10 April 2014 (11264)
TCSY paddle wheel flow sensor power checked and settings confirmed. Still unable to display water flow value. Will need to remove from system and check operation on the bench and/or replace.
david.hosken@LIGO.ORG - 17:29, Thursday 10 April 2014 (11277)
DavidH/Greg : Paddle wheel flow sensor removed, tested and was found to be working as expected. Reinstalled/reseated and now appears to be working correctly. As per installation instructions, for this install no teflon tape was used... previously used tape was removed.
H1 PSL
sheila.dwyer@LIGO.ORG - posted 10:17, Thursday 10 April 2014 (11261)
PSL restarted

Power watchdog trip, Gerardo is making plots to investigate.

H1 SEI
sheila.dwyer@LIGO.ORG - posted 10:01, Thursday 10 April 2014 (11260)
HAM 3 HEPI L4C trip

Threshold raised

Images attached to this report
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 08:20, Thursday 10 April 2014 (11258)
CDS model and DAQ restart report, Wednesday 9th April 2014

model restarts logged for Wed 09/Apr/2014
2014_04_09 07:27 h1fw1
2014_04_09 12:17 h1hpiham4
2014_04_09 12:17 h1hpiham5
2014_04_09 12:17 h1iopseih45
2014_04_09 12:17 h1isiham4
2014_04_09 12:17 h1isiham5

h1fw1 unexpected, all others due to power down of h1seih45.

H1 SEI (INS)
jim.warner@LIGO.ORG - posted 17:03, Wednesday 09 April 2014 (11257)
ITMY ISI tf running on OPSWS0

No touching, please.

H1 SEI (SEI)
richard.mittleman@LIGO.ORG - posted 16:50, Wednesday 09 April 2014 (11256)
BSC-ISI Diagram

This is to remind me (and anyone else who is involved) that we need to modify the BSC-ISI control diagram to allow all 6 degrees of freedom of stage 1 to stage 2 sensor correction

H1 SEI (SEI)
stefan.ballmer@LIGO.ORG - posted 13:02, Wednesday 09 April 2014 - last comment - 15:51, Thursday 10 April 2014(11244)
ETMX BSC ISI Performance
We Left ETMX running over night (it wasn't very windy so this should probably count as a quite time, I need to make a tool that will tell me that kind of thing).

Sensor correction was installed in three degrees of freedom last night and running. This is ground to stage 1, using Ryan's filter which is targeting the first suspension mode at 0.45Hz.

I've attached three sensor correction plots on/off, blue is sensor correction off the other colors are sensor correction on with various gains. The X direction gain ended up at 1 (which is what it was designed to be) Y and Z came out to be 0.6,
which is very weird.

  There are also three performance plots from last night, with the GS13 and T240 curves.  In general we are buried in the GS13 noise above 0.5Hz (red vs green) except at the BSC pier resonance, we do not have the HEPI L4C feed forward filters installed yet. GS13 rY and rX tilt coupling (yellow line) explains most of the low frequency gs13 signal.  There is clearly some room to relax rZ loop to reduce the gain peaking below 0.2Hz

and again none of this is Stephen's fault I can't figure out how to change the login to me

Rich 

Mabey I hope that I now have the correct plots
Images attached to this report
Comments related to this report
richard.mittleman@LIGO.ORG - 15:51, Thursday 10 April 2014 (11259)SEI

I added the projected motion at the suspension point (Longitudinal), where we aren't noise limited we are completely dominated by table X motion, which of course at low frequency is completely dominated by rotation motion (rY).

Yaw motion only couples to table rZ so I didn't plot that

 

added ETMX and ITMX optical lever signals

Images attached to this comment
Displaying reports 77221-77240 of 88163.Go to page Start 3858 3859 3860 3861 3862 3863 3864 3865 3866 End