Displaying reports 79781-79800 of 88261.Go to page Start 3986 3987 3988 3989 3990 3991 3992 3993 3994 End
Reports until 22:23, Tuesday 26 November 2013
H1 PSL
sheila.dwyer@LIGO.ORG - posted 22:23, Tuesday 26 November 2013 (8757)
Ref Cav power budget, AOM alignment

Stefan, Sheila

This morning Stefan and I returned to the PSL.  First we adjusted the AOM alingment to improve the diffraction efficency.  In the end we measured (with the filter on the power meter) 

33mW before AOM 
27.4mW after (single pass)
24.35mW after double pass

at around 74% double pass efficency, this is pretty good now.  Stefan adjusted the efficiency of the first pass by moving the AOM (mostly in pitch) and the second pass efficiency by aligning the retro reflecting mirror.  

After this the beam looked low in the apperatures of the EOM, so we moved it down, effectively undoing what Kiwamu and I did yesterday to keep the beam centered in the apperatures.  Once we had realinged the ref cav, the beam spot on the reflected camera was again in approximately the center, but now the beam spot clearly has 2 lobes when the cavity is unlocked.  Stefan removed the ND filter on the camera to make sure this wasn't an artifact, and the lobed shape remained.  

We then double checked the ref cav power budget, now making all measurements with the filter off:

23mW incident
refl (after PBS for circulator) 21.1mW (130mV on refl PD when unlocked)
locked cavity refl PD 29mV (this means 4.7mW refl unlocked)
the dark offset on this PD is 0.8mV (measured yesterday)
transmitted: 12.2mW (trans PD voltage 1.21V)

This is a visibility of 78%, but we are still lossing 25% of the power, as we were yesterday.  

We found one gost beam, which seems to be coming from the veiwport.  This light gets onto the refl PD, and causes an offset of about 1.6mV, not really significant in our power budget.

Once we were done I moved the razor blade dump that is behind the retroreflecting mirror for the AOM back about an inch so that there was room to add an iris on the leakage beam through that AOM.  
Cheryl suggested this as a way of monitoring if the beam position there drifts.  I left the iris opened so that the beam is normally dumped on the razor blade, but when the iris is closed the beam 
is right on the center. 

I also looked with the beam leveler (the aluminum one inside the PSL that Doug Cook had made, with lines scribed on it and small pin holes.)  
The path between the PMC and the ref cav is consistently silghtly below 4 inches on that leveler, but this is probably just because a different reference was used when leveling the beam. 

H1 SUS
arnaud.pele@LIGO.ORG - posted 19:02, Tuesday 26 November 2013 (8746)
HSTS TFs comparison

[Jeff K Arnaud P]

Following the DTT round of transfer functions ran during monday on the 5 HSTS suspensions of HAM2 and HAM3 chambers, we processed the data today, and the results are plotted in the attached doc. Those measurements have been taken after the optics were cleaned up and the doors were put on. ISIs were damped, HAM3 HEPI unlocked, HAM2 HEPI locked. The first attachment shows a comparison between MC1 MC2 MC3 PRM PR2 of LHO and MC3 of LLO. The second attachement is a zoomed version of the first between 0.1 and 10Hz.

Most of the results look very good and consistent with the model, and there are only a few things to notice :

* MC1 and MC3 have an extra resonance at 0.85Hz in the roll DOF which corresponds to the first vertical mode. This feature will certainly disappear with the vertical DOF damped (to try)

* MC2 has successive poles (1.516Hz and 2.07Hz) and successive zeros (1Hz and 1.094Hz) in the L DOF, which is not something we are used to see in our TFs with collocated actuation and sensing. Though, the feature is very small, and shouldn't raise concerns.

Non-image files attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 18:20, Tuesday 26 November 2013 (8756)
~0800 thru 1800 hrs. local -> continued "attended" pump down of HAM1,2,BSC1,2,3,7 combined volumes
Kyle 

Should be on Turbo at some point tomorrow 
LHO VE
kyle.ryan@LIGO.ORG - posted 18:18, Tuesday 26 November 2013 (8755)
Soft-cycled GV19 for Apollo to connect spool to GV20
Kyle
LHO VE
kyle.ryan@LIGO.ORG - posted 18:17, Tuesday 26 November 2013 (8754)
~0800 hrs. local - > Shut down LVEA purge air supply for service
Gerardo 

Replacing (4) each OE check valves
H1 CDS
james.batch@LIGO.ORG - posted 18:02, Tuesday 26 November 2013 (8753)
Repaired Burt Backup scripts
Added a line to source the epics-user-env.sh file for the proper version of epics in the burt backup scripts running on script0.  The environment was incorrect and the burt backup was failing.
H1 SEI
sebastien.biscans@LIGO.ORG - posted 17:26, Tuesday 26 November 2013 - last comment - 10:38, Wednesday 27 November 2013(8752)
SEI status

Here is the current status of the aLIGO SEI work at Hanford. The main updates of this week are:

- ITMX, HAM2 and HAM3 have been tested (chambers are closed)

- HEPI generic and local models have been updated, installed and tested

 

·         BSC1 - ITMY

o    ISI + HEPI - Unlocked, Previously commissioned.

·         BSC2 - BS

o    ISI + HEPI - Unlocked, Previously commissioned.
 

·         BSC3 - ITMX

o    ISI : Testing complete, in chamber. Report validated.

o    HEPI : Unlocked.

 

·         BSC9 - ETMX

o    ISI : Unlocked. Testing complete.       

o    HEPI : Unlocked, ongoing initial alignment.

·         BSC10 - ETMY

o    ISI : Currently installed in BSC6. Will be pulled out and installed in BSC10. Payload (SUS) will be moved then. Electronics are disconnected

o    HEPI : Unlocked.

         HAM 1

o    HEPI: Locked and vented.
      Low priority testing 

·         HAM2

o   ISI: previously commissioned with HEPI locked, currently unlocked, in vacuum

o   HEPI - IPS position loops and alignment offsets installed
     Locked

·         HAM 3

o   ISI: previously commissioned with HEPI locked, currently unlocked, in vacuum

o   HEPI - IPS position loops and alignment offsets installed
     Unlocked

·         HAM 4 

o   ISI: In chamber, Previously tested during assembly validation, currently locked, no suspension installed, in-vac cables not connected.
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Model is running, and MEDM screens are available in the Sitemap.

o   HEPI: Currently locked, to be commissioned
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Model is running, and MEDM screens are available in the Sitemap.

·         HAM 5

o   ISI: In Chamber, Previously tested during assembly validation, currently locked, no suspension installed, in-vac cables not connected,
     Chamber temporarily closed.         
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Model is running, and MEDM screens are available in the Sitemap.

o   HEPI: Currently locked, to be commissioned     
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Model is running, and MEDM screens are available in the Sitemap.

·         HAM 6

o   ISI: 
     in chamber.
     Unlocked, no SUS
     Mechanical adjustments complete
     Initial in-chamber testing complete, but not validated yet

o   HEPI: Locked

 

Happy thanksgiving everybody
Comments related to this report
hugh.radkins@LIGO.ORG - 10:38, Wednesday 27 November 2013 (8760)

Corrections to Status as of 26 Nov:

BSC9--ISI is Locked

BSC10--HEPI is locked (No Payload)

HAM6--ISI Locked

LHO General (CDS, PEM)
patrick.thomas@LIGO.ORG - posted 17:25, Tuesday 26 November 2013 (8751)
Tagged and moved to tested dust monitor code
This falls under WP 4303.

The dust monitor code tested under WP 4287 survived the weekend. The difference seems to be running it with 'procServ' instead of 'screen'.

I made tagged releases of the tested code and updated the target directories in /ligo/lho/h0/target. The support module was tagged as met_one_227b_comp_ctrl-1.2.0 and the IOC directory was tagged as dust_met_one_227b_comp_ctrl-1.2.0. I changed the startup scripts in the target directories to use 'procServ'.

I restarted the IOCs from the target directories on h0epics.
LHO General
cheryl.vorvick@LIGO.ORG - posted 16:04, Tuesday 26 November 2013 (8750)
OPS Summary

- EX feadthrough work

- dust monitor code change

- close GV19

- install spool X in LVEA

- reinstall cryopump EX

- test stand reinstall/level EY

- X arm spool oplev piers - drilled anchor bolts

- replace  SUS and ISC HAM-A coil drivers, which are actually IO optics

- pull cables HAM6 to electronics room

H1 IOO (IOO)
cheryl.vorvick@LIGO.ORG - posted 15:59, Tuesday 26 November 2013 - last comment - 12:34, Wednesday 27 November 2013(8749)
IM (aka HAM AUX, HAM-A, HAUX...) coil driver change

Coil drivers were changed for IM1, IM2, IM3, IM4, and all offsets required changes.  This was complicated by choosing to do this change on the day we started pumping down the vertex, i.e. optics are moving due to pumpdown - choose comparisson times wisely.  Spreadsheet attached shows times used and old and new offsets.

Non-image files attached to this report
Comments related to this report
cheryl.vorvick@LIGO.ORG - 10:10, Wednesday 27 November 2013 (8759)

Reset OSEMINF offsets to old values - changed alignment drives to recover optic positions, but we are saturating because the reduction in driver strangth is too much, and IM3 is still 300urad from it's aligned position - not good, won't work. 

Images attached to this comment
jeffrey.kissel@LIGO.ORG - 12:34, Wednesday 27 November 2013 (8768)CDS, INS, IOO, ISC, SUS
For more details, see LHO aLOG 8767.
H1 TCS (TCS)
greg.grabeel@LIGO.ORG - posted 15:33, Tuesday 26 November 2013 (8748)
Viewport Cover for TCS
Tyler G. Greg G.
Fabbed up some sheet metal covers for the BSC 1 and 3 viewports. These were installed to make the viewports compliant with our laser safe standards. They don't have warning labels on them saying not to be removed, so try and avoid removing them.
Images attached to this report
H1 SUS (INS)
jeffrey.kissel@LIGO.ORG - posted 15:27, Tuesday 26 November 2013 - last comment - 12:18, Wednesday 27 November 2013(8745)
SUS Closeout Measurements -- PR3 and ITMX Look Good. Yellow Flags but no Show Stoppers
J. Kissel

I've gathered full sets of close out transfer functions for H1SUSPR3 (and HLTS) and H1SUSITMX (a wire-suspended QUAD). The results look good enough to proceed with pump down!

Yellow Flags:
H1SUSPR3 -- The Q of the 1st first vertical mode appears to be reduced from previous measurements of the free in-air suspension. I attach the .pdf of the raw DTT results for this DOF as well, to show that the coherence is still good for this resonance, implying a real loss mechanism. This is also noticeable on the R and T degrees of freedom as well, again only on the first resonance. But all resonant frequencies are in the same place, so the dynamics are as expected and well-behaved. In the end, we want these modes damped anyways, right? However if it is a real source of loss, then it's a source of noise. However, given that these are all the lowest frequency resonance, and it's the V/R DOFs it means that the loss is most likely on the top blade springs -- well away from the optic, so what ever excess noise is present will be filtered by the otherwise free SUS.

H1SUSITMX -- The only thing awry here is that the R0 V and R DOFs show much higher response (an overall DC scale factor) than expected. However, it was immediately obvious that this is a result of calibration filters not turned on. Taking a look, we immediately discovered this to be the case -- the "to_um" filters has been turned off for ONLY the R0 LF and RT OSEMs. They're now turned on, and we will be sure to capture a new safe.snap so this problem doesn't arise again.


All data and common scripts (with updated meas:ists) are committed to the SusSVN as of this entry.
Non-image files attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 12:18, Wednesday 27 November 2013 (8765)

Sorry - that was my bad - I turned these 2 filters off in order to test before shutting the doors and did not get them turned back on.

H1 AOS
jason.oberling@LIGO.ORG - posted 14:32, Tuesday 26 November 2013 (8744)
ETMx ACB Alignment
IAS: J. Oberling
SLC: M. Vargas
 
Aligned the ETMx ACB this morning.
H1 SUS (SUS)
richard.mccarthy@LIGO.ORG - posted 14:23, Tuesday 26 November 2013 (8741)
ETM-X SUS cabling shield to ground check.
Tested the cables at the Sat. Amp connector to Ground.  Verifying Pin 13
Was attached to Shield then Pin 13 to Ground.
H1:SUS_ETMX-1 PASSED
H1:SUS_ETMX-4 PASSED
H1:SUS_ETMX-7 PASSED
H1:SUS_ETMX-16 PASSED
H1:SUS_ETMX-19 PASSED
H1:SUS_TMON-1 Failed.  Showed short to ground somewhere between Sat Amp and OSEM.
H1:SUS_TMON-4 PASSED
H1 SUS
richard.mccarthy@LIGO.ORG - posted 14:21, Tuesday 26 November 2013 (8740)
ETM-X ESD cabling
Hugh Radkins and Richard M

Tested the ETM-X ESC cable.  Hugh was kind enough to work inside the chamber while I checked the connection from outside.  ON first inspection 3 out of the 5 pins were making contact.  Hugh removed the connector then reseated it rocking it back and forth as he inserted it.  This seemed to work.  He then tightened the connection alternating between screws until the unit was tight.  I retested all of the pins and we have connection through the system.
H1 CDS
david.barker@LIGO.ORG - posted 14:09, Tuesday 26 November 2013 (8737)
h1oaf0, h1susey, h1seiey, h1iscey down for IO Chassis work

h1oaf0 was powered down to add a additional ADC and DAC to the IO Chassis. The computer remains down for now due to the EY systems being offline

At EY, h1susey, h1seiey and h1iscey are down to rearrange the cards in their IO Chassis to match the EX configuration.

H1 IOO
kiwamu.izumi@LIGO.ORG - posted 12:06, Tuesday 26 November 2013 - last comment - 15:01, Tuesday 26 November 2013(8731)
Rotation Stage is now functional and ready to go

Patrick, Kiwamu

This is a follow-up work of the PSL power control rotation stage (see #8606). The punch line is that:

This morning, we installed a +/- 24V power supply cable to enable the relay circuits for the interlock. This power cable connects the interface box, which is currently sitting on the PSL table next to the periscope (see #8606), and a LIGO-standard power strip underneath the PSL table. I confirmed that it lighted up an LED on the front panel of the interface box. Then I connected the two-pin motor power and DB15 cables at the Beckoff chasis which had been disconnected 10 days ago (see #8593) for a safety purpose. To plug them back in, I powered off the chasis for approximately a minute. Then, I powered it up again after I plugged them.

We tested the rotation stage to see if it is functional. At the beginning, because the interlock was at the disable position (the mechanical switch was in its down position), the rotation stage didn't move at all regardless of what kind of command I sent. This is good as this is how it is supposed to be. Then we switched the interlock to the enable position by toggling the switch. This then allowed the rotation stage to move. So it is working fine and ready to go.

Note that, at the moment, the rotational stage doesn't have a waveplate in it. Plus, the stage is sitting aside the main path, so it is not going to do anything for the main beam.

Comments related to this report
patrick.thomas@LIGO.ORG - 15:01, Tuesday 26 November 2013 (8747)

PLEASE NOTE THAT IT IS NOT CLEARED TO BE PUT IN THE LASER PATH.

Logbook Admin General
jonathan.hanks@LIGO.ORG - posted 10:48, Tuesday 26 November 2013 - last comment - 14:31, Tuesday 26 November 2013(8729)
LHO aLOG outage today at 12:15pm Pacific time - Please save all entries prior to this time.
I will be taking doing maintenance on the LHO aLOG today at 12:15pm
Pacific.

Please have all entries posted to the logbook or saved to a draft before
12:15pm.

It will NOT be safe to work on an entry after that point until I have
sent an all clear notification (which will include a comment on this aLOG entry).

If everything goes smoothly the aLOG will go through a few phases:

* total outage (a few minutes)
* read only while the system is being verified
* back to normal use

The work will not extend the functionality of the aLOG.  It is a
operating system upgrade and a relocation which will be a step towards
making the LHO computer users room an overflow for the control room.
Comments related to this report
jonathan.hanks@LIGO.ORG - 13:36, Tuesday 26 November 2013 (8732)
The upgrade is complete.  This comment is to verify that the L-mail works.
jonathan.hanks@LIGO.ORG - 14:03, Tuesday 26 November 2013 (8736)
Maintenance is largely done.  There is one outstanding issue, the L-Mail notifications are no longer working.

Feel free to use the aLOG, but note, the mail notifications may not be working.
jonathan.hanks@LIGO.ORG - 14:31, Tuesday 26 November 2013 (8743)
Mail notifications are working.  The aLOG maintenance is complete.
Displaying reports 79781-79800 of 88261.Go to page Start 3986 3987 3988 3989 3990 3991 3992 3993 3994 End