mark.barton@LIGO.ORG - posted 10:06, Monday 24 September 2012 - last comment - 12:16, Tuesday 25 September 2012(4278)
Resuming BSFM02 testing
Mark B.

Picking up where I left off on Friday, aiming towards getting TFs.
Comments related to this report
mark.barton@LIGO.ORG - 09:48, Tuesday 25 September 2012 (4287)
Mark B.

Done for the day. Had chronic problems trying to get TF scripts to run, so reverted to a free-swing test to at least get the mode frequencies. Most of the LF modes seem to be where they're supposed to be but there's a huge anomalous peak at 11 Hz in all DOFs but especially V and R.
Non-image files attached to this comment
travis.sadecki@LIGO.ORG - 12:16, Tuesday 25 September 2012 (4290)

I went in to diagnose what might be causing the anomalous 11Hz peak and found that the Top Stage blade EQ stop (aka the goalpost) was locking the right side blade down.  I released this, then made a few small adjustments to correct for the now fully suspended chain/BOSEM alignment.

H2 CDS
david.barker@LIGO.ORG - posted 08:26, Saturday 22 September 2012 (4276)
H2 CDS code tagged in SVN as H2OAT_RCG2.5.1

We have put all of the H2 CDS code into the cds_user_apps SVN repository. I have created a One Arm Tag to archive the code base for H2 as it was at the end of the OAT run. H2 BSC6 commissioners may now transition the code away from the OAT configuration.

H1 IOO
cheryl.vorvick@LIGO.ORG - posted 17:38, Friday 21 September 2012 (4275)
3" steering mirror behind PR2 installed in HAM3
- Cheryl, Deepak, Luke

The 3" steering mirror behind PR2 was installed in HAM3.  The 3" black glass that sits behind the mirror in it's mount turned out to be more like 2.8", so the set screw is almost fully through it's threaded hole, and does firmly hold the black glass in place.  The 3" optic had the First Contact removed from the back surface, and there appeared to be possible FC left  around the very edge in a number of places.  I wiped the edge with acetone, and some features were removed, but most remained, and after looking at it with Betsy, it seemed like the features could be the edge of the AR coating.  I put the optic in it's mount, with the HR side still covered with FC, and we installed it into HAM3.

Work installing into HAM3 will continue on Monday.
H1 ISC
keita.kawabe@LIGO.ORG - posted 16:11, Friday 21 September 2012 (4274)
ISC misc. notes for HAM3

* Black glasses and clips used for all ISC mirrors were found and are ready to be installed (but IO black glasses are not yet ready). As noted before, this can be done later.

* Sled is ready as noted before.

* Picomotor interface and the manual driver are ready so we can test picomotors in chamber once they're installed.

* Ditto for QPD.

H1 SEI
hugh.radkins@LIGO.ORG - posted 16:07, Friday 21 September 2012 (4273)
LHO HEPI System Status
The final distributed piping on HAM4 was completed today.  The distributed tubing from BSC8 has been reinstalled on BSC1.  And a little more of the temporary tubing was removed.
The main supply & return lines are what remains.
H1 SUS
betsy.weaver@LIGO.ORG - posted 16:03, Friday 21 September 2012 (4272)
IMCF06, IMCF09 secondary prisms removed

Due to concerns of improper strains placed on the glass via the metal secondary prism, the prisms were removed from the MC1 and MC3 optic barrels.  These will be reglued on with a new curing procedure shortly.  The debonding process, E1200821, took ~3-4 hours of continual "baby sitting" by me and Gerardo to keep the prism joint wet with acetone.

H1 SEI
hugh.radkins@LIGO.ORG - posted 16:03, Friday 21 September 2012 (4271)
BSC2 BS ISI Assembly Status
JimW MitchellR & GregG

The crew got a portion of the Sensors installed on to the ISI.  These included the Trilliums and the Vertical L4-Cs & 1 Horizontal GS-13.  
Images attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 15:04, Friday 21 September 2012 (4269)
dust monitor in clean room over ISI
I put a dust monitor in the clean room over the ISI. It was set to location number 2 in the LVEA. It is in there but does not seem to be running correctly.
X1 SUS
mark.barton@LIGO.ORG - posted 14:16, Friday 21 September 2012 - last comment - 15:47, Friday 21 September 2012(4268)
BSFM02 TF work starting
Mark Barton

Travis reports that the OSEMs on the BSFM02 are adjusted so I'll be trying to take TFs. The Matlab scripts are a bit old, so it may be more debugging than taking data to begin with.
Comments related to this report
mark.barton@LIGO.ORG - 15:47, Friday 21 September 2012 (4270)
Mark B.

As expected a lot of time was consumed in debugging (mostly getting the actuation going). Damping now works on L, T, P and Y, but enabling it on T or V produces ringing. Didn't get to TFs yet - need to go home now. Edited to add: By applying individual OSEM offsets I was able to confirm that the M1 magnet signs are correct. 
X1 SUS
betsy.weaver@LIGO.ORG - posted 10:14, Friday 21 September 2012 - last comment - 11:25, Friday 21 September 2012(4266)
BSFM02 Phase 1 - Using H2 FMy model/controls

We'll be using the BSC8 cables/controls/models to test BSFM02, so the FMy MEDM settings will be changed for this testing phase.

Comments related to this report
betsy.weaver@LIGO.ORG - 11:25, Friday 21 September 2012 (4267)

Attached are the new INMON settings for BSFM02 based on the OLVs measured this morning.

Images attached to this comment
X1 SUS
mark.barton@LIGO.ORG - posted 09:59, Friday 21 September 2012 (4265)
Created directory for BSFM02
Mark Barton and Betsy Bland

We created a directory, ^/trunk/BSFM/X1/BSFM02 , in the SUS SVN for the BSFM suspension about to be tested on the solid stack in the LVEA. Because it's Phase 1 testing, we declare it honorary X1, despite the facts that:

* It was originally intended as H1:BS.

* It is now slated to be repurposed as I1:BS.

* It will be tested with H2:ITMy cabling and channels.


H1 AOS
betsy.weaver@LIGO.ORG - posted 09:50, Friday 21 September 2012 (4264)
BSFM02 (I1 BS)

Travis, Betsy

The BS which had been built for H1 on the solid stack/test stand in the LVEA is now destined for India.  (The FMy from BSC8 is due to become the new H1 BS.)  Travis has resumed work on the BS in order to finish it and stow it for India, thus making space for the BSC8 rework for H1.  In line with the standard way we had been naming suspensions, this BS is now being dubbed "BSFM02" as it will be built and tested only to Phase 1 prior to storage.  BSFM02 has been coarsely aligned.

LHO General
patrick.thomas@LIGO.ORG - posted 18:31, Thursday 20 September 2012 (4262)
plots of dust counts
Attached are plots of dust counts > .5 microns approximately from 6 AM to 6 PM in particles per cubic foot.
Non-image files attached to this report
H1 ISC
keita.kawabe@LIGO.ORG - posted 16:54, Thursday 20 September 2012 - last comment - 06:51, Friday 21 September 2012(4261)
HAM3 POP IR QPD sled completed

We tuned the QPD sled Gouy telescope using the modemaster and a fiber coupled source. Basically copied LLO, however the difference in source parameter means that some of the things are different. Details about the source and the tuning parameters etc. will be detailed in T1200433, which is yet to be written.

Then we have centered the QPDs using hand held QPD LCD readout box (D1102092). QPD cables were clamped down on the sled.

(Turned out that the hand held box had a pin compatibility issue. I, Richard McCarthy and Rich Abbott talked, and Richard made a patch job so I can go on. Rich is going to modify the rest of the units at Caltech.)

We've wrapped it in a foil and put it in a big ameristat bag.

One caveat, though, is that it turned out that we don't have a suitable black glasses that fits the J-clamp for 1-inch optics (at least in the lab). Also, rectangular black glasses that are supposed to be installed just outside of the sled were too thick and didn't fit the V holders.

We will be able to install them when we go in to HAM3 for real alignment in the future, not this time.

Comments related to this report
corey.gray@LIGO.ORG - 06:51, Friday 21 September 2012 (4263)

Attached are a few photos from the build.  ALL photos from work are in ResourceSpace, here.

Images attached to this comment
X1 SUS
stuart.aston@LIGO.ORG - posted 16:40, Thursday 20 September 2012 (4258)
PRM (HSTS) M1-M1 Un-Damped Transfer Functions for Completion of Phase 1b Testing
[Stuart A, Jeff B]

Following previous M1-M1 TF measurements taken for PRM (HSTS) which exhibited signs of environmental noise coupling into the Role and Pitch DOFs (see LHO aLOG entry 4232), TFs have now been re-taken during a quieter period. 

The first plot (2012-09-20_1215_X1SUSPRM_M1_ALL_TFs.pdf) shows a comparison between PRM and the HSTS model.

The second plot (allhstss_2012-09-20_1445_All_Phase1b_HSTSs_ALL_ZOOMED_TFs.pdf) shows a comparison between PRM and every other HSTS suspension that has completed Phase 1b testing for both sites.  

The TFs obtained for PRM are in good agreement with the model, and fall within the scatter of modal peaks observed for other suspensions. Therefore, this should now finally complete Phase 1b testing of this suspension. 

All data, plots, results and scripts have been committed to the SusSVN as of this entry.    
Non-image files attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:38, Thursday 20 September 2012 (4260)
BSC2 BS ISI assem#3 in Cleanroom
JimW GregG & Hugh & the fantastic Cleaning Crew Karen & Christina!

The cleanroom was spotless and the can was polished.  We pulled the lid and drove the ISI on the container base into the cleanroom.  It will start getting podded tomorrow
H2 SEI
hugh.radkins@LIGO.ORG - posted 16:35, Thursday 20 September 2012 (4259)
H2 SAT HEPI Temporary Tubing is 95% gone
EricA JimP Keith Filiberto & Hugh

We continued emptying the last of the fluid in the lines.  Eric disconnected the BSC8 chamber tubing from the 4-way valves and plugged the tubing.  Then he removed the Accumulators from the Manifolds.  Jim & Keith then took the tubing out from the BSC.  The supply mains were then pulled east and cut to extract them from the OMC area.  THere are a few hangers etc on the chamber but those will be pulled in the AM.
All the cable pulling is compete, CPS racks are removed as are the Dial Indicator trees.

Do we have to pull the Cable trays to put in the Walking Plates?  Do we need the Walking Plates?
Displaying reports 84461-84480 of 88617.Go to page Start 4220 4221 4222 4223 4224 4225 4226 4227 4228 End