T240 Huddle Test - Shipment Load #4386 - Pressure Readout Investigation

JimW, HugoP,

We recently huddle-tested the T240s received in LLO's shipment #4386. We took power specra that look fine. We also checked the pressure readouts which appeared surprisingly low: ~40kPa instead of the usual ~100kPa.

We investigated this issue and found that it was caused by a model discrepancy at X1, which does not match what is installed at ETMY and ITMY (see attached screenshots of the models: X1, ETMY, ITMY).
Pressure signal processing at X1:                      Pressure_Displayed   =   Pressure_Input * 2.879e-3
Pressure signal processing at ETMY/ITMY:       Pressure_Displayed   =  (Pressure_Input * 5.065e-3 ) + 30.625

If we reverse the processing applied at X1, and then apply the one of ETMY/ITMY we then obtain:
( 40kPa / 2.879e-3 * 5.065e-3) + 30.625 = 101 kPa    
... Which is what we expected in the first place. The four T240 pods received in shipment #4386 were huddle-tested OK at recption. Results are available under the seismic SVN.

 

Other measurements performed during the investigation, at X1:
-We read 0 kPa when nothing is plugged into the T240 interface
-We read ~40 kPa with the T240s are plugged in
-We measured 8.36V at the T240 interface (D1002696) "to-Anti-Alias" output
-The power supplied to the T240 interface is:
   -17.96V
   +17.75V

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 16:11, Tuesday 18 September 2012 (4228)
Day Shift Summary

Today marked the official end of the 1-Arm Test (laser powered down at EY [laser safe there now], venting of Y-Beam Manifold, etc.)

H1 SUS
betsy.weaver@LIGO.ORG - posted 15:14, Tuesday 18 September 2012 - last comment - 16:05, Tuesday 18 September 2012(4238)
MC3 Phase 2a testing Prep

MC3 has all 6 top BOSEMs plugged in and backed off in prep for new OLVs and gain settings.  As well, we've attempted to fix the side BOSEM flag cross coupling - we indeed found the flag to be mounted quite crocked and have straightened it.  TFs will tell us if the cross-coupling is alleviated.

Comments related to this report
betsy.weaver@LIGO.ORG - 15:57, Tuesday 18 September 2012 (4240)

While rechecking the open light voltage offsets on the MC3 INMONs, I noticed that the T2 BOSEM gain was set to 1.405 (likely instead of 1.045).  Possibly this is what was causing heart ache during the testing phase immediately after the build across the street in the staging building on this sus.  The gain should now be set to 1.049 since I remeasured with the sus on the production cables/electronics.  Attached is a snapshot of the inmon setting before my work today.

Images attached to this comment
betsy.weaver@LIGO.ORG - 16:05, Tuesday 18 September 2012 (4241)

And the new settings from today snapshotted below - mostly small number tweeks except for the T2 gain noted above.

 

The burt restore file to be used should be the cds auto one at:

/ligo/cds/lho/h1/burt/2012/09/18/17:00/h1susmc3epics.snap

Images attached to this comment
H1 CDS
david.barker@LIGO.ORG - posted 13:14, Tuesday 18 September 2012 (4237)
restart of models on h1sush2b and h1susauxh34

The user models on h1sush2b (IM) and h1susauxh34 were found to be stopped. Also the IOP models on these front ends had a large timing offset, consistent with a timing/Dolphin error.

I restarted the models on both of these front ends with no problems.

H1 INS
jodi.fauver@LIGO.ORG - posted 12:40, Tuesday 18 September 2012 (4235)
BSC9 ICC
All brushing was completed this morning. First vacuum was completed this afternoon and wipe-down got started.
H1 SUS
jeffrey.bartlett@LIGO.ORG - posted 11:04, Tuesday 18 September 2012 - last comment - 14:13, Wednesday 19 September 2012(4232)
H1-PRM Cross Coupling
   There was a transverse to yaw cross coupling noted in the TFs for H1-PRM (orange trace). To isolate the problem we moved the side BOSEM to the other side of the suspension and re-tested. With the BOSEM on the opposite side, the cross coupling disappeared (black trace). Before moving the BOSEM back to its correct side position, I found the magnet/flag base to be misaligned. This was corrected and the BOSEM was re-centered to 50% light. Subsequent testing shows the cross coupling has been removed (purple trace). 
 
   H1-MC3 and H1-PR2 also show the same cross coupling. We will check the side magnet/flag base alignment on these two suspensions and re-align as necessary.  
Non-image files attached to this report
Comments related to this report
stuart.aston@LIGO.ORG - 14:13, Wednesday 19 September 2012 (4247)
[Stuart A, Jeff K and Jeff B]

Adjustment of the PRM (HSTS) side flag mounts rectified the Y to T cross coupling observed in previous measurements.

But something else appears to have cropped up. The plots below (allhstss_2012-09-19_0940_All_Phase1b_PRMs_ALL_ZOOMED_TFs.pdf) show a comparison between the latest two complete data sets of un-damped M1-M1 TFs, with the most recent being the orange trace. It can be seen that these recent TFs exhibit signs off:-

- Roll (slide 4) looks to show stronger vertical mode coupling at ~0.85Hz
- Pitch (slide 5) looks to show stronger vertical mode coupling at ~0.85Hz

Most likely, these are sensor-related cross couplings -- as in the usual imperfect subtraction of common mode signal (Vertical) in the differential signals (Roll and Pitch). But they were not so apparent in the 2012−09−06_2000 data, and we wish to be sure that they are not related to the re-alignment carried out on PRM to rectify the Y to T cross coupling.

To demonstrate the significane of these Pitch and Roll cross couplings, we provide a plot showing similar couplings for ALL HSTSs from both sites (allhstss_2012-09-19_1040_All_Phase1b_HSTSs_ALL_ZOOMED_TFs.pdf). This demonstrates that compared to other HSTSs the feature in pitch (again the orange trace) is less of a concern. However, the feature in roll could be considered egregious.

It should be noted that the most recent PRM TFs were taken during the middle of an active day. Therefore, the next data will be taken at a quieter time, when the common mode (Vertical) signal is reduced (or by just turning on the Vertical damping loops while taking the Pitch and Roll measurements with loops open).

All plots and scripts have been committed to the sus SVN as of this entry.
Non-image files attached to this comment
H1 FMP
jodi.fauver@LIGO.ORG - posted 11:02, Tuesday 18 September 2012 (4231)
BSC8 De-Install/BSC1 Install Prep
Christina and Karen will do a gross cleaning of the uncovered Test Stand and vicinity this morning. That should give us some idea of how many cleanings will be required to get things into reasonable shape to receive the cartridge.
H1 FMP
jodi.fauver@LIGO.ORG - posted 10:55, Tuesday 18 September 2012 (4230)
BSC2 Install Prep
Phase 1 Cleaning of the HAM cleanroom is complete and signage posted. 
LHO VE
john.worden@LIGO.ORG - posted 10:25, Tuesday 18 September 2012 - last comment - 14:30, Tuesday 25 September 2012(4229)
ENDY Pumpdown - slope change??

There appears to be a favorable slope change starting ~ Aug 8 (65 days on this log/log plot) Browsing the aLOG I find that near that time there were ring heater operations, and one week prior to this Kyle disconnected a small turbo pumping the BSC6 annulus. I don't think either of these explain the slope change. I also looked at the big ion pump voltages during this period - there were no step changes anywhere near this time.

GV18 was cycled on August 7-8 -Rai might have been making RGA measurements?

Images attached to this report
Non-image files attached to this report
Comments related to this report
rainer.weiss@LIGO.ORG - 12:27, Tuesday 18 September 2012 (4234)
John, You are correct I was making measuremants and moving the gate valve on both August 7 and 8. It seems that the slope 
became 1/t after the measurements. It is not easy to understand this. The first thought would have been a leak
in the valve between the RGA and the chamber with a poor vacuum in the RGA. This is not the case as the 2 liter/sec 
ion pump was holding the pressure in the RGA volume below that in the chamber. Another possibility is that the annulus system
was leaking but you rule this out from Kyle's measurements. I am stumped.
RW
 
john.worden@LIGO.ORG - 13:03, Tuesday 18 September 2012 (4236)

Kyle decoupled the annulus turbo pump on July 31 - probably  not this.

A signal we do not yet have is the BSC 6 annulus ion pump current as this chamber and it's pump were brought from the mid station. - I'll ask Dave about this.

john.worden@LIGO.ORG - 14:30, Tuesday 25 September 2012 (4292)

Kyle recalls that he disconnected the annulus turbo pump for noise reasons at the request of Robert rather than for vacuum reasons. Some days later he was surprised to find that the annulus ion pump had "come on scale"  as if the pressure had fallen in the annulus space to the point where the ion pump could start.

This suggests that there may be an inner oring leak from the annulus to the BSC6 chamber which might explain the slope change. Once the annulus ion pump began pumping, this gas load was removed from the chamber.

Richard has our electrician working at connecting up our new annulus ion pumps to the CDS system so that in future we will be able to trend these signals. At the time we did not assign any priority to this work.

LHO General
james.batch@LIGO.ORG - posted 08:35, Tuesday 18 September 2012 - last comment - 12:26, Tuesday 18 September 2012(4227)
GDS Control Room Software changed
A new version of gds software has been installed for Ubuntu and Mac OS X workstations.  The notable differences appear in foton and diaggui.

Widgets for displaying channel names have been made much wider, forcing the layout of several screens to be changed.  Diaggui measurement tab now shows 2 columns of channels instead of 3.  Diaggui excitation tab has two channel name widgets for each excitation, the wider length required these to be put on separate lines.  The plot options panel on the result tab is also wider to accomodate long names - this affects foton as well.  Since the plot options panel is wider, there's less room for the actual plot, but the option panel can be detached so it "floats" which should allow plenty of room for the plot.  The Export popup dialog in diaggui also has channel name fields that have been made wider, and there's now an option to add a header to the ASCII export file.  The header contains information to allow identification of the source of the data.

Complaints should be addressed to me or filed with bugzilla.
Comments related to this report
james.batch@LIGO.ORG - 12:26, Tuesday 18 September 2012 (4233)
I have reverted GDS tools to the previous version, 2.16.3 due to a bug discovered by Hugo.
H1 SUS
jeffrey.garcia@LIGO.ORG - posted 21:16, Monday 17 September 2012 - last comment - 23:24, Monday 17 September 2012(4225)
Remote Measurements on H1 SUS MC2 beginning
Measurements to begin at ~9:00 PM PST.
Comments related to this report
jeffrey.garcia@LIGO.ORG - 23:24, Monday 17 September 2012 (4226)
Measurements completed.
LHO General
patrick.thomas@LIGO.ORG - posted 18:34, Monday 17 September 2012 (4224)
plots of dust counts
Attached are plots of dust counts > .5 microns in particles per cubic foot.
Non-image files attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 17:15, Monday 17 September 2012 (4223)
Payload Installed HAM1 & Optical Table almost Level
ScottL & HughR

Payloaded HAM1 Optical Table per D1200524.  This is 310lbs which stays on in place plus 40lbs to substitute for the ISC equipment that will eventually go onto the Table.  I've got the Table level to ~+-0.15mm but the elevation is low by 15mm.  We'll continue to work this Tuesday.
H1 INS
jodi.fauver@LIGO.ORG - posted 15:38, Monday 17 September 2012 (4222)
BSC9 ICC
Hand brushing of the upper chamber was completed this morning. Half of the BSC flooring was stacked to expose half of the lower chamber: both pneumatic and hand brushing were completed on the exposed half. The flooring was replaced and the other half stacked to expose the other side of the lower chamber.
Displaying reports 84481-84500 of 88602.Go to page Start 4221 4222 4223 4224 4225 4226 4227 4228 4229 End