Displaying reports 84981-85000 of 88488.Go to page Start 4246 4247 4248 4249 4250 4251 4252 4253 4254 End
Reports until 09:08, Thursday 26 July 2012
X1 SUS
james.batch@LIGO.ORG - posted 09:08, Thursday 26 July 2012 (3605)
Tripleteststand survived the night
The tripleteststand had the One-stop cable and cards (between the computer and the I/O chassis) replaced yesterday in an effort to solve the mystery of the models freezing and the cards in the I/O chassis becoming invisible.  The x1sushxts27 model was started Wednesday 7/25 at 14:06 PDT and is still running this morning.  
LHO VE
john.worden@LIGO.ORG - posted 08:21, Thursday 26 July 2012 (3604)
END X vented

The END X volume was vented yesterday so work may proceed at BSC9. During turbo pump startup we found that the QDP80 was rotating the wrong way. This was corrected and the turbo was spun up as a precaution.

LHO VE
john.worden@LIGO.ORG - posted 08:18, Thursday 26 July 2012 (3603)
Vertex volume pumping down.

I started pumping the LVEA vertex volume yesterday.  Roughing was paused overnight and will continue today. Pressure is currently 60  torr.

H2 ISC
bram.slagmolen@LIGO.ORG - posted 23:54, Wednesday 25 July 2012 (3601)
PLL servo

We looked into the PLL servo. First we checked the temperature feedback signals to the laser. They did seem ok, although the green had a 1mV offset (although not being written to it). We disconnected the green temp feedback.

The IR laser crystal temperature feedback was ok, but only after we managed to reset it to zero. Even the EPICS display was not showing all the digits (we got an intergrator gain of 1e-6). The EPICS screen displays voltage, which is good to know.

We had to adjust the temprature on the laser to find the beatnote, it was set back to 42.1 deg C. The knob on the front panel is very 'coarse', so the beatnote was within 10 MHz from the nominal 39.7 MHz. We engaged the temperature servo and we saw the beatnote move towards the 39.7 MHz. The Phase-Frequency Discriminator has a flat gain when the beatnote is far away from the LO frequency (39.7 MHz). Although not a problem, with low gain you do wait for it:) You can speed it up by engaging the CMB-A servo, which feedback to the PZT. Matter of fact, the temp signal is a plain copy of the PZT signal, which goes through the Beckhoff system and has it sown little servo.

We looked on an oscilloscope at the temperature feedback signal. There are a few ripples in the signal at ~1 micro second, ~5 microseconds and ~2 milli seconds. I think we should add an analog 10 Hz low pass filter at the output to remove these. The temperature feedback has a bandwidth of up ~0.5 Hz anyway.

Looking at the PZT feedback signal. It has ~1.5Vpp 'oscillations' with a ~10s period appearing and then fading away. This is of course the 'equivalent' noise the laser tries to follow. The PZT frequency to volts conversion is ~3 MHz/V, so that indicates that the laser frequency fluctuates by ~4.5 MHz!

Looking a the I-mon from the Phase-Freq Discriminator it is flat when locked (and around the 39.7 MHz). When further away the signal looks like 'pulse-widht-modulated' with an average voltage which correspond to how far away the beatnote is and is expected. I don't know how far the beatnote needs to drift, at which point the frequency discriminator takes over from the phase discriminator. All-in-all the I-mon doesn't seem to be bad or noisy.

H2 ISC
bram.slagmolen@LIGO.ORG - posted 19:30, Wednesday 25 July 2012 - last comment - 23:58, Wednesday 25 July 2012(3598)
Cavity lock with large VCO drift

We looked into the PLL which seemed to be ok (see other entry 3601). We didn't pay much attention to the RefCav yet, as we want to to make the cavity lock again. To make this happen we had to reset the ETMY HEPI, lucky Fabrice was here to help. The output on ISC BLEND_RZ was off. All is well.

We have fringes again, and the REFL_PWR_MON seems to be at its previous healthy ~11000 counts level. When engaging the cavity locking (CMB-B), it seemed to be ok until is starts the oscillation at 10-20 sec period. I turned the first boost filter off which didn't seem to help much. The VCO frequency drifts upto 39.78 MHz (from 39.603 MHz nominal). It almost looks like there is a sign wrong, it locks, fluctuates around 0 then creeps to the -10V limit. When you look at the VCO frequency it keep slowly climbing. At the same time the cavity power drops. Hmm, maybe still something in the PLL servo is not right.

We have two new indicator on the OAT screen, 'RefCav Trans (V)' and 'Beatnote at (Hz)'. The first one is nominal at 1.1 V (has a green box when above 0.8V, and a red box when <0.4V), and indicates if the RefCav is locked. The Beatnote shows the VCO frequency in Hz, nominal at 39.603 MHz.

I left the cavity unlocked, but the PLL engaged.

A good .snap time is Wed July 25 2012, 20:00h (and half hour from now).

Comments related to this report
bram.slagmolen@LIGO.ORG - 23:58, Wednesday 25 July 2012 (3602)

Could the 'pulse-width-modulation' effect (lack of a better discribtion), and the drift of the beatnote away from the LO, be the reason that the laser is behaving strange?

H2 PEM
bram.slagmolen@LIGO.ORG - posted 19:11, Wednesday 25 July 2012 (3600)
Dust monitor alarm

The H2 dust monitor alarm went off. Not sure what button to press, so I pressed silince for one hour ...

LHO General
bram.slagmolen@LIGO.ORG - posted 19:11, Wednesday 25 July 2012 (3599)
Tumble weeds cleaning

At 7:08 the tumble weeds are being gathered.

H1 AOS
jeffrey.kissel@LIGO.ORG - posted 19:09, Wednesday 25 July 2012 (3597)
Oplev ASDs (Preliminary Calibration)
J. Kissel, T. Vo

Now that the optical lever signal chains are functional, it's straight forward to include Thomas' calibration into the signal chain and grab a spectra. Attached are the results for ETMY and ITMY. I'm not sure if I believe the amplitude of the results though. Even though Fabrice has been making excellent progress with H2 ISI ITMY, I don't think we're down to the sub- nrad / rtHz at 0.5 Hz. We'll go through the calibration more thoroughly tomorrow, and see where I've screwed up.

Anyways, for posterity, my calibration is as follows (which, although Thomas only has official calibration for ETMY, I used the same calibration for both assuming the signal chains and lever arms are roughly the same):
 
DOF     ADC Gain         Oplev Calib.   (order of mag.)
Pitch: 40/2^16 [V/ct] * 1666 [urad/V] * 1e-6 [rad/urad] = 1.0168e-6 [rad/ct]
Yaw:   40/2^16 [v/ct] * 1727 [urad/V] * 1e-6 [rad/urad] = 1.0541e-6 [rad/ct]

Non-image files attached to this report
H2 SEI
fabrice.matichard@LIGO.ORG - posted 19:01, Wednesday 25 July 2012 (3596)
ITMY Longitudinal Isolation
Blend Filters were refined on ITMY. The current state is:

750 mHz in Stage 1 RX and RY
250 mHz in Stage 2 All dofs, and Stage 1 X, Z, RZ
100 mHz on Stage 1 Y

The plot attached shows the latest isolation results (Red is Damped, Blue is Isolated).

We are converging toward a configuration that we should be able to copy/paste on other units.


Otherwise, I was having to turn the loops in the low blend configuration. The "boost" filters were making glitches in the actuators output, tripping the watch dogs. I modified the output compensation filters to filter out the glitches. The turn on/off process is now smooth and do not trip the watchdogs anymore.


Non-image files attached to this report
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 18:52, Wednesday 25 July 2012 (3591)
Optical lever updates
J. Kissel, T. Vo, R. McCarthy

After installing the new QPD.mdl library part and getting the channels reflected onto the the QUAD MEDM screens, we found nonsense coming out after the normalisation step of the signal processing. Here, "nonsense" is defined as 
Input to the normalization:
Pin = -2400
Yin = -2900
SUM = -10700
Output of the normalization:
Pout = Pin / SUM = 2.4e+9 = nonsense
Yout = Yin / SUM = 2.9e+9 = nonsense

Given that this library part is working quite well for the rest of the LIGO world that's using it, it implies that there's something screwy going on with our signal chain.

We then tried turning off the signal input and inserting offsets with small (off order 1), known values to provide simple tests to see if the normalization was functional. With just offsets, the signals make sense. DAH! After a little more head scratching and a few more rounds of guess and check, I realized the difference between the input signals and the offsets I was trying: the raw input signals are negative (which Thomas informs me is expected from the electronics). *ACHOO!*

Inverting the sign in the SEG (input filters), all works great. My guess is that the RCG Saturation Part, which has its limits set to [1e-6,1e12] treats the negative numbers as the lower limit, and divides the signal by 1e-6. (Hence 2400 / 2.4e9 = 1e-6).

An analog signal chain red-herring that led to some interesting discoveries:
We'd suspected initially that there was some high-frequency content saturating the ADC (that made it not visible in EPICS variables). A spectra of the raw segment channels, up to 7 kHz, later revealed no such features.

However, while we still suspected this was true, we dove into the whitening chassis just to better understand the signal chain (since it's the only thing between the QPD and the AA chassis). We discovered that, though originally designed to have one, the ISC whitening board (D1001530), which is internal to the Oplev Whitening Chassis (D1100013), did NOT have its daughter board that fixes the state of the typically-digitally-controlled, switchable-state filter board. Mohana had some extra, and will ship some over night. Once those are in place, we can play around with the whitening and gain to find a good state in which we can leave it.
LHO General
patrick.thomas@LIGO.ORG - posted 18:19, Wednesday 25 July 2012 (3595)
plots of dust counts
Attached are plots of dust counts > .5 microns in particles per cubic foot.
Non-image files attached to this report
H2 SUS
szymon.steplewski@LIGO.ORG - posted 17:32, Wednesday 25 July 2012 (3594)
Exciting ITMY and ETMY suspensions
Today from ~ 3:00 pm to 5:20 pm local time I excited the TOP stage of the Y arm suspensions (first ITMY, then later ETMY) in order to gather peak height data to help with diagonalizing the OSEM sensor readbacks.  Power spectra were recorded with damping at the top stage turned OFF, while an excitation of white noise was simultaneously injected into all 6 degrees of freedom of the top stage.  The XML templates are saved in the suspension directories:


/ligo/svncommon/SusSVN/sus/trunk/QUAD/H2/ETMY/SAGL2/2012-07-25_top_actuation_ETMY_4times_power.xml

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H2/ITMY/SAGL2/2012-07-25_top_actuation_test.xml


I also tried to drive the L2 stage of ITMY with damping OFF at the top stage, but failed to get any coherence in this power spectrum measurement.
H1 SEI
hugo.paris@LIGO.ORG - posted 17:01, Wednesday 25 July 2012 (3593)
HAM3 -- In Chamber Testing -- Preparation progress

Dave and I finished installing the models, and MEDM screens, for HAM3. 

I built the HAM3 testing folder arborescence, filled HAM3 matrices and started trying the scripts we will use for the in-chamber testing.

In-field cables arrived today. Richard and his crew started installing them.

HAM3 balancing is planned tomorrow. This balancing will be performed with the BNC outpus of the CPSs' ADE boxes.

LHO General
jeffrey.garcia@LIGO.ORG - posted 16:31, Wednesday 25 July 2012 (3592)
Ops Log
Various activities 
- rebooting of SUS models for QUADs in the morning, another in the afternoon
- Thomas Vo to End-Y station
- noisy work in the LVEA from ~1:00PM - 3:00PM
- leak detecting work in the Optics Lab

H1 SUS
jeffrey.bartlett@LIGO.ORG - posted 16:14, Wednesday 25 July 2012 (3590)
Testing MC3 After Creek Bake
   After creek baking and reassembling H1-MC3, the Lower Blade break off heights did not come back to their pre creek bake values. There was a greater than the 0.5mm vertical tolerance between the four blade tips. We tweaked several suspension adjustments but could not bring the tips into compliance. The best we could get was a maximum of 0.75mm height difference between the blade break offs. All other parameters are well within spec. 

   We ran transfer functions on the M1 level to see if the suspension would perform correctly with the Lower Blade heights a bit off. Jeff K., Andres R., and I looked over the plots and compared H1-MC3 with several other suspensions. H1-MC3 compares favorably with the other HSTS suspensions. It was decided to install the AOSEMs and start Phase 1b testing.       
H1 SUS
jeffrey.bartlett@LIGO.ORG - posted 15:46, Wednesday 25 July 2012 (3589)
Restart X1 Triple Test Stand after replacing cards in IO Chassis
   We continue having problems with Tripleteststand loosing communications with the IO Chassis. Tripleteststand did not recover after power down power up reset. Richard M. replaced cards in the IO Chassis and Jim B. restarted IOP, the x1sushxts27 model, and Burt restored the system from 20120622-x1sushxts27_PR2.snap. The Tripleteststand is up and  appears to be running normally.
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 15:36, Wednesday 25 July 2012 (3587)
Quick recompile, reinstall, restart, and restore of QUAD models
During the QUAD models updates last week, the
/opt/rtcds/userapps/release/sus/common/src/
corner of the userapps repository had not been updated, so we didn't receive Joe Betzwieser's PUM stage fix to the
/opt/rtcds/userapps/release/sus/common/src/CD_STATE_MACHINE.c
bit of c-code that controls the analog and digital filtering interaction between the coil drivers.

In addition to updating that corner before the recompile, I also added two EPICs monitor blocks between the MTRX and normalization steps in the 
/opt/rtcds/userapps/release/isc/common/models/QPD.mdl
library part. This change has been committed to the trunk.

Finally, I made sure to capture the current status of the QUADs (as the ISC team left while trying to lock the cavity this morning), in
/opt/rtcds/userapps/release/sus/h2/burtfiles/itmy/h2susitmy_H2OAT_110725.snap
/opt/rtcds/userapps/release/sus/h2/burtfiles/etmy/h2susetmy_H2OAT_110725.snap

and then turned off the damping loops and master switches, left the latest P and Y offsets the offsets in place, and captured new safe.snap files, which are used here:
/opt/rtcds/userapps/release/sus/h2/burtfiles/itmy/h2susitmy_H2OAT_110725.snap
/opt/rtcds/userapps/release/sus/h2/burtfiles/etmy/h2susetmy_H2OAT_110725.snap
but are actually symbolic links to
/opt/rtcds/userapps/release/sus/h2/burtfiles/etmy/h2susetmy_safe.snap
/opt/rtcds/userapps/release/sus/h2/burtfiles/itmy/h2susitmy_safe.snap

With these two changes in place, I recompiled, reinstalled, restarted, AND restored.

The new epics variables are now visible on the optical lever screen (see attached), and Szymon is confirming whether the L2 drive is now functional.
Images attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 13:28, Wednesday 25 July 2012 - last comment - 10:10, Friday 03 August 2012(3586)
H1 HAM3 HEPI Actutors Attached & Released--IAS says OK! Prt Duex
OK now we have all the HEPI Actuators attached & released at the correct elevation and IAS has signed off on the position.

Elevation & level is 0.1mm below nominal of -250.5mm (wrt LIGO Global) with a +-0.1mm levelness.

Attached is my field notes of the final dial indicator readings and the level survey-enjoy.

Thanks to Mitchell & Jason
Non-image files attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 10:10, Friday 03 August 2012 (3712)
I misspeak above where I say wrt LIGO Global.  The number above, -250.5mm is the LIGO Global elevation corrected to the local leveling field.  The HAM ISI Optical Table is positioned to -252.9mm.  2.4mm is the correction to local level hence the -250.5mm; please pardon the confusion. -H
H1 AOS
thomas.vo@LIGO.ORG - posted 15:07, Monday 23 July 2012 - last comment - 08:50, Thursday 26 July 2012(3543)
H2 ETMY Optical Lever Calibration
I have taken the calibration data and analyzed it. The plot of the linear response curve is attached.

I used a polynomial fitting program in python to get these numbers.  This should give you the conversion from volts to micro-radians.

           Slope            Y-intercept
Pitch   [  1.01902201e+06   8.42886118e+00]
Yaw     [  9.83122943e+05  -1.19329010e+01]
Comments related to this report
thomas.vo@LIGO.ORG - 19:11, Monday 23 July 2012 (3550)
Please hold off on using these calibration parameters, it looks like the SUS readout channels that map out the quadrants on ETMY and ITMY were not correct and I will need to re-calculate if this is true. Updates soon to come.
thomas.vo@LIGO.ORG - 14:25, Tuesday 24 July 2012 (3564)
The QPD mapping did prove to be different than what was previously shown on the MEDM screens.

Here are the new values for the linear response curve. The units are micro-radians/volts. The lever arm is taken to be 6 meters still 

Pitch [ 1727.67131855    23.41350328]
Yaw   [ 1666.80728788   -33.14694715]


It is relevant to address that a positive pitch on the ETMY quad suspension MEDM on the m0 stage will yield a higher intensity on the two lower quadrants of the optical lever QPD, giving a negative pitch as viewed facing the QPD. 
Also, a positive yaw in the quad suspension MEDM will yield a higher intensity on the two left quadrants of the optical lever QPD, giving a negative yaw as viewed facing the QPD. For alignment purposes this will be important to note.  

The next step is to take measurements over the course of at least 2-6 hours and measure the drift as a function of time.
Images attached to this comment
thomas.vo@LIGO.ORG - 08:50, Thursday 26 July 2012 (3588)
I copy and pasted wrongly into the screen the pitch and yaw are reversed, this is signal(1/m) vs translation(micro-radians) which gives units of micro-radians*meters.
       Slope              Y-intercept
Pitch [1666.80728788   -33.14694715]
Yaw   1727.67131855    23.41350328]

Apologies
Images attached to this comment
Displaying reports 84981-85000 of 88488.Go to page Start 4246 4247 4248 4249 4250 4251 4252 4253 4254 End