Displaying reports 85741-85760 of 88367.Go to page Start 4284 4285 4286 4287 4288 4289 4290 4291 4292 End
Reports until 21:43, Thursday 26 April 2012
H1 PSL
oliver.puncken@LIGO.ORG - posted 21:43, Thursday 26 April 2012 (2710)
Disassembly of the PSL (Part 4)
PSL installation team


The diode boxes had been craned over from the H1 LDR to the H2 LDR and installed into the diode rack.

The gantry crane had been disassembled, cleaned, and reassembled inside the H1 LAE. It had been used to get the PSL oscillator from the optical table to a set of dollys. It still stored in the ante room and will be brought to the H1 LAE with the facility crane. The DBB, the MOPA and a big part of the optics from the PSL table are wraped and stored in the H2 LDR.

The cameras for monitoring H1 PSL activities inside the H1 LAE are installed and the rooms have been cleaned.

The TV screens needed for work inside the laser enclosure are unmounted from the H2 LAE walls and ready to be reassembled inside the H1 enclosure.
Images attached to this report
H2 SUS
deepakmanoj.nandakumar@LIGO.ORG - posted 17:58, Thursday 26 April 2012 (2698)
MC3 Assembly Notes

[Jeff B, Deepak K, Andres R and Gerardo M2]

Wednesday 25th April 2012

 - All the subassemblies were built alongside the MC1 subassemblies.

 - The Lower mass was assembled and weighed (2890g) and checked with the weight on the nebula page (2993g).

 - The intermediate mass was assembled and weighed with the add-on mass. The extra weight for the lower mass is added to the intermediate mass bringing the total weight of the mass to 2996g.

 - The lower blades were assembled and 1/4th of the total intermediate and lower weights are hung to each blade (1472g).

 - The distance from the frame to the blade is measured from 2 extreme points (Near the Clamp and at the neck of the blade).

 

Thursday 26th April 2012

 - After about 3 trials the blade clamps for the lower blades are chosen such that with the blades remain parallel to the frame when the weight is added. The different trials and the clamps used are recorded in the MC3 Traveler.

 - The upper mass was then assembled and weighed with the add-on mass (3115 g).

 - The upper wires were pulled and the intermediate wires are pulled too.

 - The upper blades were assembled to the frame along with the blade guards.

 - The EQ stops are were assembled on to the frame.

H2 AOS
douglas.cook@LIGO.ORG - posted 16:58, Thursday 26 April 2012 (2709)
BSC^ IAS alignment ready to go
We setup the alignment equipment at END y including the PLX in situ. Surprising enough we actually have a return autocollimator signal. At first look the ETM is pitch ~350 uradians (target is <160 uradians) and yaw first look is 1200 uradians (target is <160 uradians). When the ISI folks finish up balancing the optic table we will continue with the axial, translation, elevation measurements.
Doug/Jason
LHO General
jonathan.berliner@LIGO.ORG - posted 16:43, Thursday 26 April 2012 (2707)
Thursday Ops Log
- EY: IAS, SEI, SUS, and TMS usual work. Newtonian noise accelerometer installation. h2pemeyaux crashed due to poorly installed board...then fixed.
- BSC8: SEI, SUS, COC usual work by BSC8. Viewports swapped out at BSC8. Richard sorting out cabling.
- PSL: Plumber arrived to investigate suspected leak in chiller line. Continued migration of PSL from H2 to H1
- OSB: Unusually heavy rains in the morning. Doors locked at 4:05pm
H2 PEM
jenne.driggers@LIGO.ORG - posted 16:41, Thursday 26 April 2012 (2708)
Newtonian noise array installed!
[Jenne, Jan, with much help from Rich and crew, DaveB and crew]

We have finished installing our 44 accelerometers out at End-Y.  Again, please be mindful of the cones and cables.  Everything should be secure, and except for the cones which are nice and bright orange, there shouldn't be any trip hazards.  

We checked the data briefly, and all of the channels look good so far.  We'll have a look at the overnight data in the morning to make sure it's all okay.  One of the Isotrons (accelerometer power / amplifier box) that we have out there doesn't have the 10x gain that the other 2 do, so we may decide to change it out if the quiet nighttime ground motion is sitting on the ADC noise.  We'll switch out the box tomorrow if necessary.  

Some photos are attached, which show most of the array.

Thanks for all the help over the past 2 weeks, and we'll be back after the One Arm Test is complete to clean up and remove the array.
Images attached to this report
H2 PEM
gregory.mendell@LIGO.ORG - posted 13:13, Thursday 26 April 2012 (2706)
NNARRAY channels added to PEM RDS frames
Starting from

 1019424512 GPS
 == Apr 25 2012 14:28:17 PDT
 == Apr 25 2012 21:28:17 UTC

the PEM RDS frames at LHO (frame-type PEM_RDS_A6) contain the NNARRAY
channels. 

These are all H2 channels, such as H2:PEM-EY_AUX_NNARRAY_ACC_1_OUT_DQ.

These frames are written to directories under

 /archive/frames/A6/PEM_RDS/LHO

at LHO and are transferred to Caltech.

They will also be available via NDS2, which is the protocal 2 NDS server
run by LDAS at LHO, LLO, and CIT.

In total, from the above time, 748 channels matching NNARRAY were added
to the PEM RDS frames. This includes 44 that are sampled at 1024 Hz.

With this same change, I also picked up 97 new channels that match
IOP-PEM_EY_AUX, and these two channels:

H2:IOP-PEMEYAUX_DCU_ID
H2:PEM-EYAUX_DCU_ID

(Note the PEM RDS frames contains any channel that has PEM in the name,
though I have to up date the list by hand, any time the PEM channels
change names.)
H2 AOS
keita.kawabe@LIGO.ORG - posted 12:27, Thursday 26 April 2012 - last comment - 10:03, Tuesday 01 May 2012(2705)
TMS and HAM6 inspection (Frank, Betsy, Calum, Keita)

We inspected several things. More pictures were taken than shown here, which are to be posted to resource space by Calum.

1. Washers that were stuck

There are four stainless washers used for TMS temporary restraint that were stuck to the aluminum bracket (see  picture). I tried to lift them all gently, and they wouldn't move at all. Might be possible to ply it off using some tool, but we agreed it's not worth the risk of flipping and flying them to break wires.

2. A cable that is not connected

There was one cable that is not connected yet, and we identified it as the ring heater cable connecting CB-3 and the vacuum feed through (F3-3C2). This is going to be taken care of later.

One thing I noticed is that the floor order for this bracket is reversed. CB-3 first floor (closest to the  ISC table) should be one of the ETMY SUS cables, and the second floor should be the ring heater according to D1101478, but in reality it was the opposite (see the second picture, the white-ish cable is for the ring heater).

It's easy to tell the difference because of the color, but I think it's still a good practice to install things as specified for future workers.

3. One of the TMS cables was brushing the HWS mirror

The cable sagged, apparently. We fixed this (see the third and the fource picture).

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 10:16, Monday 30 April 2012 (2727)

Boo. BSC6, not HAM6.

betsy.weaver@LIGO.ORG - 10:03, Tuesday 01 May 2012 (2732)
Note - When I assembled the cable connectors on those brackets, I fed back all of the changes I made to the layout guys (SYS).  I am waiting for an update to the cable layout drawing based on these.  The order of the "flooring" of the connectors in the bracket make more sense the way they are now, hence redlines to the drawing.
H1 PSL
oliver.puncken@LIGO.ORG - posted 20:57, Wednesday 25 April 2012 (2703)
Disassembly of the PSL (Part 3)
PSL installation team

The new diode rack is now prepared to be packed. Also, the laser diode boxes and power  supplies are moved out of the old rack, but still stored in the LVEA. The pump light fibers / communication fibers had been pulled from the H1 LDR and the H1 LAE. The spools are stored on the rail inside the LDR (see attached picture).
Images attached to this report
H2 SUS
jeffrey.garcia@LIGO.ORG - posted 20:43, Wednesday 25 April 2012 (2702)
Measurements running on H2 SUS ITMY
The gps time when the measurements began is: 1019445220
Date and time now (Pacific Time): 04-25-2012 20:13

Measurements are running on CDSWS1 in the LVEA through an ssh -X session as "controls" on Jeff G.'s laptop.
LHO General
patrick.thomas@LIGO.ORG - posted 19:00, Wednesday 25 April 2012 (2701)
plots of dust counts
Attached are plots of dust counts > .5 microns.
Non-image files attached to this report
H2 SUS
jeffrey.garcia@LIGO.ORG - posted 18:32, Wednesday 25 April 2012 (2700)
H2 SUS ITMY M0/R0 TFs
The attached are transfer function measurements on the ITMY QUAD M0/R0 top masses from the night of 04/24/2012.  There are some apparent higher-frequency resonances above 50Hz.  The measurements were taken up to 50Hz with 0.1Hz resolution from 3Hz to 31Hz. From 29Hz to 51Hz, the resolution is 1Hz.  To note, the ISI had one of it's stages locked, while the other was floating.  The resonances seen in the OSEM data could be attributed to this ISI condition. This state appears to have had a significant effect particularly on the R0 Transverse DoF. The data is indicative of a locked mass that cannot swing freely. Also, the resonances are at the same three frequencies for both chains, which would suggest the ISI table is creating them.

As of tonight, the BSC 8 ISI is floating on both stages and has been balanced.

Tonight, new measurements will be run on ITMY with higher resolution above 30Hz and with the bandwidth expanded to 100Hz.  This will slightly increase the measurement time.



Non-image files attached to this report
H2 ISC
daniel.hoak@LIGO.ORG - posted 17:56, Wednesday 25 April 2012 (2699)
ALS table work (Alberto, Frank, Dan, Aidan on the phone)
We got the alignment of the ALS table, including the various Hartmann wavefront sensor paths, into an almost-final state.

We discovered that one of the lenses in the TCS pickoff from the returning ALS beam was converging instead of diverging.  This has been temporarily swapped for a correct, but 1064-coated, lens from the optics lab.  A lens coated for 532nm is on its way.  With a correctly-shaped lens in the path, the beam on the HWS is now about the right size.  (A quick beamscan made us think it's a little larger than it's supposed to be; we'll let experts wrestle with it at a later date.)

After considering the periscopes for quite a while, and thinking about drilling holes in various places, we decided the most elegant solution to the ALS/HWS periscope problem was to swap the vertical periscope mounts, so we would have more screw holes to work with.  This allows us to mount the ALS periscope baseplate as intended, and kludge a HWS beam periscope below that.  Pictures attached (from my iPhone - d'oh!).

Modulo some further tweaking, the table layout and alignment should now reflect D1100607-v7.
Images attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:46, Wednesday 25 April 2012 (2695)
BSC3 iLIGO SEI Extracted
Apollo-Mark Randy Zack Caleb & Scott

No real issues to report.  We should fuss with the bungees on the cleanroom ceiling but otherwise she slipped right out and Dale has his Springs and seats.  Everything else is ready for the recycler.  A few photos for proof.  Thanks Crew!
Images attached to this report
H2 CDS
david.barker@LIGO.ORG - posted 16:42, Wednesday 25 April 2012 (2697)
Newtonian Noise Front End Installation
Jim, Cyrus, Dave

we installed the Newtonian Noise front end system at the EY end station. It is part of the aLIGO H2 system, using a spare DCU_ID.

The new machine is called h2pemeyaux. It has the IP address 10.201.0.40 and is on the H2 IPMI system.

Its IOP is called h2ioppemeyaux, dcu_id=40. The user model is h2pemeyaux, dcu_id=41 running at 2048Hz. The model reads 44 accelerometers and acquires them to the frame at 1024Hz.

Initially it was found that the duotone signal on the first ADC (chan31) was bleeding into channel 15. Relocating the second ADC to its correct PCI slot has fixed this problem. The IOChassis has a DAC card installed, but the front end does not see this card at all. The DAC card is not immediately needed for the NN project.

The channels in the DAQ are named H2:PEM-EY_AUX_NNARRAY_ACC_n_OUT_DQ when n is in the range 1..44
H2 DAQ
david.barker@LIGO.ORG - posted 16:35, Wednesday 25 April 2012 (2696)
H2 DAQ data corruption
After a transition to partial mode (not writing frames) and back it was found that h2fw0 was creating corrupt data frames. The transition was made to support LDAS QFS disk reconfiguration.

So data written by h2fw0 and served by h2nds0 in the following time period is corrupt. You should use h2nds1 to serve data in this time period

start:
4/24 22:21UTC 3:22pm local
end:
4/25 17:25UTC 10:25am local

We (CDS and LDAS) are investigating what happened. We will put in checking software to alarm if this happens again.
H1 INS
cheryl.vorvick@LIGO.ORG - posted 16:06, Wednesday 25 April 2012 (2694)
H1 iLigo ITMX deinstall - optic removed from BSC3:
The new 5/16 bolts worked well with the adaptor plate, and the optic was removed from the chamber.  The optic was wrapped and secured on the Straddle Lift, and the Straddle Lift was lowered to it's lowest level, for transporting the optic to the optics lab. 

FYI: the class-B hardware for lifting the "lift table" in and out of the chamber, was installed in a way that didn't make sense to me, and others agreed, so we reworked the hardware configuration for lifting the lift table - picture will be attached.
H1 CDS
cyrus.reed@LIGO.ORG - posted 15:07, Wednesday 25 April 2012 (2693)
CDS Core Network Changes Complete
Cyrus, Jim B., Dave B.

Beginning Monday (and finishing Tuesday), we cut over to the new CDS core switch.  From the network perspective, this is the last major central change required to support both H1 and H2 installation and is the foundation for implementing everything else remaining.  What is left is to install are the new edge switches that support the vacuum and auxiliary systems, which will likely happen in the coming weeks/months.

The initial cut over took about an hour, and we used the remaining time to clean up cabling and the configurations of the switches that will remain in the near and long term, and to perform testing.  The 'old' cdsnat0 and cdsnat1 have been decommissioned.  cdsnat0 has been replaced by rtr-msr-nat0, which is a PC running the Vyatta open source router system.  It handles the NAT functionality for the CDS control network, and the port forwarding for the limited CDS services available to the open internet.  The functionality of cdsnat1 (which never actually performed any NAT...) in routing between the internal CDS subnets is now provided directly by the Layer 3 core switch, a Cisco Catalyst 4503E/Sup7e.  The core switch also handles forwarding the udp broadcasts from the ops network to the front end network for diaggui/dtt testpoint discovery on port 5355.  Attached to the core switch are all the edge switches that support, for example, the H1 and H2 FE networks, the Ops network, and (for now) what remains of the legacy iLIGO Foundry equipment (running the vacuum and FMCS networks).
H2 CDS
dan.moraru@LIGO.ORG - posted 14:47, Wednesday 25 April 2012 (2692)
changed QFS mount options for ldas-h2-frames
Unmounted ldas-h2-frames yesterday afternoon from all LDAS systems (gateway, lhoarchive, qfs-nfs1) and CDS h2gw0.  Explicitly enabled the 'writer' mount option on h2gw0 to avoid caching, replacing the following line in /etc/vfstab:
ldas-h2-frames                  -               /ldas-h2-frames          samfs   -       yes     -
with:
ldas-h2-frames                  -               /ldas-h2-frames          samfs   -       yes     writer

Per the man page,

# man mount_samfs
...
writer    Sets the file system to type writer.  There can be
               only one host system that has the file system
               mounted with the writer option at any one time.
               If writer is specified, files are flushed to disk
               at close and directories are always written
               through to disk.  The option atime = 1 is set for
               writer.

               Prior to the 4.0 release, the writer option was
               specified as the shared_writer option.  The older
               syntax is supported for backward compatibility.

The mount options on all LDAS systems were left unchanged:

ldas-h2-frames                  -               /dcs-h2-frames          samfs   -       yes     reader

The filesystem was then remounted and NFS-shared out, first on h2gw0, then on the LDAS QFS readers.

The LDAS systems have not logged any more 'Bad directory validation errors' relating to ldas-h2-frames since the change.  There have been warnings pertaining to cds-h2-frames:

qfs-nfs1:~ # dmesg
...
Apr 25 08:28:35 qfs-nfs1 samfs: [ID 756621 kern.warning] WARNING: SAM-QFS: cds-h2-frames: inode 0x2bdbf has a Bad directory validation error
Apr 25 08:28:35 qfs-nfs1 last message repeated 3 times
Apr 25 08:55:10 qfs-nfs1 samfs: [ID 756621 kern.warning] WARNING: SAM-QFS: cds-h2-frames: inode 0x2bdbf has a Bad directory validation error
Apr 25 08:55:34 qfs-nfs1 last message repeated 7 times
Apr 25 09:19:34 qfs-nfs1 samfs: [ID 756621 kern.warning] WARNING: SAM-QFS: cds-h2-frames: inode 0x2bdbf has a Bad directory validation error
Apr 25 09:20:03 qfs-nfs1 last message repeated 7 times
Apr 25 09:44:05 qfs-nfs1 samfs: [ID 756621 kern.warning] WARNING: SAM-QFS: cds-h2-frames: inode 0x2bdbf has a Bad directory validation error
Apr 25 09:44:33 qfs-nfs1 last message repeated 7 times
Apr 25 10:09:03 qfs-nfs1 samfs: [ID 756621 kern.warning] WARNING: SAM-QFS: cds-h2-frames: inode 0x2bdbf has a Bad directory validation error
Apr 25 10:09:03 qfs-nfs1 last message repeated 3 times
Apr 25 10:35:36 qfs-nfs1 samfs: [ID 756621 kern.warning] WARNING: SAM-QFS: cds-h2-frames: inode 0x2bdbf has a Bad directory validation error
Apr 25 10:36:03 qfs-nfs1 last message repeated 7 times
Apr 25 11:00:05 qfs-nfs1 samfs: [ID 756621 kern.warning] WARNING: SAM-QFS: cds-h2-frames: inode 0x2bdbf has a Bad directory validation error
Apr 25 11:00:34 qfs-nfs1 last message repeated 7 times

The 'writer' mount option was added to /etc/vfstab on h2gw1 yesterday as well, but that filesystem has not been remounted and thus the change has not yet taken effect.
H2 AOS
jason.oberling@LIGO.ORG - posted 12:23, Wednesday 25 April 2012 (2691)
IAS Pitch/Yaw Measurements
IAS: D. Cook, J. Oberling
SUS: B. Bland
 
Performed final pitch/yaw alignment of BSC08 ITMy this morning:

These are within our spec for mechanical alignment adjustments (±160 µrad pitch/yaw), therefore IAS is now done at BSC08 and will begin to transition to BSC06 this afternoon.

H1 AOS
jim.warner@LIGO.ORG - posted 11:02, Wednesday 25 April 2012 (2690)
BSC8 Balanced and ready for IAS
I went back into BSC8 this morning to fix the ISI's weight problem. Ended up bolting 7 of SUS's dog clamps at various points around the optical table, mostly around the top of the quad. I tried to be careful to not to pinch any cables or interfere with any moving parts. We may not be exactly back to where we were ~2 months ago, but everything is back into spec, or at least as close as we can get. IAS is in now taking final measurements.
Displaying reports 85741-85760 of 88367.Go to page Start 4284 4285 4286 4287 4288 4289 4290 4291 4292 End