Displaying reports 86261-86280 of 88268.Go to page Start 4310 4311 4312 4313 4314 4315 4316 4317 4318 End
Reports until 18:15, Tuesday 24 January 2012
LHO General
patrick.thomas@LIGO.ORG - posted 18:15, Tuesday 24 January 2012 (2079)
plots of dust counts
Attached are plots of dust counts > .5 microns.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 10:46, Tuesday 24 January 2012 (2077)
dust monitor LVEA 1
I attached an isokinetic probe to the dust monitor at location 1 in the LVEA and turned it back on. It is sitting near the floor in the area by BSC3.
LHO General
patrick.thomas@LIGO.ORG - posted 18:55, Monday 23 January 2012 (2075)
dust monitors. plots of dust counts
I replaced the fuse in the breakout box for dust monitor 7 in the LVEA (near the previous location of the H2 electronics racks). It had turned off at what looks like around January 22, 2012 12:00 UTC (from a plot of H0:PEM-LVEA_DST7_MODE).

I turned off the dust monitor at location 1 in the LVEA, which had previously been sampling the enclosure around ISCT4, as it was sitting on the floor without an isokinetic probe attached. It has probably been running without one since ISCT4 was removed. I would not use its data since then.

Attached are plots of dust counts > .5 microns.
Non-image files attached to this report
H1 ISC
daniel.hoak@LIGO.ORG - posted 18:01, Monday 23 January 2012 - last comment - 15:29, Tuesday 24 January 2012(2074)
Uninstall of HAM6 OMC
Keita, MikeL, JohnM, DanH

We un-installed the OMC and associated cabling, QPDs, and optics from HAM6 this afternoon.  The OMC SUS is currently clamped down and double-wrapped in aluminium foil and AmeriStat on the top level of a rolling cart next to HAM6.  The SUS frame is dog-clamped to a cleaned optics bench on the cart.  We'll crane the whole thing over to its temporary home inside the ISCT4 meat locker soon.

From the top of the HAM6 ISI, the optics, tip-tilts, balance masses, hardware and cables were removed and were wrapped in aluminum and double-bagged in ameristat.  We put everything in five plastic containers next to the ALS table (in the mini optics lab) in the LVEA.  There are many hockey puck weights on the floor next to HAM6.

The components removed from HAM6 and stored in the containers are:

Black glass beam dumps:

3 double-glass V-shaped dumps
2 single-glass dumps
2 L-shaped dumps
1 flat dump (from overhanging the edge of the table)
some small black glass pieces

Tip-tilts:  TT0, TT1, TT2, optics removed.

Optics:

3 mirrors (from tip-tilts, individually bagged and labeled)
3 hi-reflectors: part numbers IP122-32, 33, and 37
1 CVI BS1-45P
1 CV1 mirror
1 CVI mirror-type-thing, with wedge, and with a chip on the side
1 CVI lens, PLCX-50.8-250.5C 

Optic Mounts:

5 2" DLC mirror mounts, one with a bad pitch adjustment (bagged individually, labeled as such)
2 2" lens mounts (one was used for a hi-reflector)

Dog clamps & clamps for mirror mounts

1/4-20s, separated by Ag-plated, SS, and vented SS

OMC QPD1 & 2, with cables, and cable connector bracket
Comments related to this report
daniel.hoak@LIGO.ORG - 15:29, Tuesday 24 January 2012 (2078)
OMC on the move!
Images attached to this comment
LHO VE
kyle.ryan@LIGO.ORG - posted 16:07, Monday 23 January 2012 (2073)
LN2 delivery today @ Y-end, CP7 alarm should go away in a cycle or two


			
			
H2 PSL
richard.savage@LIGO.ORG - posted 17:05, Saturday 21 January 2012 (2072)
H2 FSS tune-up
PeterK and RickS

Today we used the Agilent RF analyzer to investigate the FSS OLTF.  We tried to make this measurement from outside the LAE, but found that the necessary cables (In1, In2, Test2 in) were not run from the TTFSS to the field box.
We found that the common gain (and likely FAST gain) sliders were not able to take advantage of the full range of the AD602 variable gain stages.  The conversion from slider units (0 to 1) to gain (-6 to 24 dB) is 0.031 slider units per dB with 0.5 slider units corresponding to 10 dB.  It seems that the channel is set up to give +,- 500 mV range and the AD602 needs +,- 625 mV to give the full -10 to 30 dB range.

We adjusted the half wave plate for the RefCav path to 190 on the dial to give more power such that we could achieve the desired UGF (to take advantage of the phase bubble) of about 450 kHz where we have about 52 deg. of phase margin (see attached plot, not that the UGF is at -10 dB on this plot).  The Common/FAST gains are 0.969/0.930.

After adjusting the gains, the Lock Acquisitions counter is at 277 when we left the LAE.
Images attached to this report
H2 AOS
robert.schofield@LIGO.ORG - posted 12:48, Friday 20 January 2012 (2071)
Arm cavity baffle: installation photos, glint search and contamination control

Summary: Photos show arm cavity baffle installation and the view of the baffle from the ITM and ETM. Part of a reflective bellows can be seen from the test mass through the H1 hole. I include a photo of the interior baffle surface that could be used as a dust witness plate near the test mass. Particle counts measured during installation did not exceed 100/ft^3 (>=0.5um).

 

Installation photos:

Figure 1 is an annotated selection of installation photos that Lisa A. took.

Glint search:

Figures 2 and 3 show photos taken to look for potential retro-reflections  - in particular, to find surfaces that reflect light scattered from the beam spot on one of the test masses back to the beam spot. This retro-reflection, and reflection to the beam spot on the opposite test mass, are thought to be the dominant paths for scattered light noise. For the side of the baffle viewed by the ETM beam spot, Figure 2, the camera and flash were set up in the beam path many meters from the baffle. The brightest retro-reflections from within the clear aperture were from the diodes and their mounting screws and from the edges of the bends in the baffle.

For the ITM side of the baffle (wide-angle scattering side), Figure 3, I placed the camera at the location of the beam spot on the test mass, except that I had to use the side that didn’t have an optic. The baffle is close to symmetrical so I believe that the actual beam spot would have a similar view of retro-reflections from the inside of the baffle. The brightest retro-reflectors (at least at visible wavelengths) are the backs of the photodiodes, screw heads, and the bellows on the spool between the manifold and BSC8, which can be seen through the hole on the opposite side of the baffle. The outside of this bellows would be a good place to mount a shaker to test for scattering problems. It would be possible to block the view of this bellows with a divider between the two sides of the baffle.

Contamination control:

The large equipment was first staged in the Y-manifold while the dam was located in the spool piece, separating cleaned BSC8 from the un-cleaned manifold. I had recently found that particle levels were ten times higher in the manifold than in BSC8 for similar activity levels, here, and wanted to use the dam to keep manifold activities from contaminating BSC8 and the ITM. Immediately after transport, I measured particle levels in the manifold next to the dam to be about 1000/ft^3 (0.5 um or larger). After the particle level reached about 150/ft^3 (~20 minutes of sitting), I removed the dam and left carefully. As I was leaving, I measured the particle level at about 200/ft^3.  

For our work in BSC8, we had to walk a short distance into the manifold to retrieve the staged equipment, so I wanted to have clean air flowing out of  BSC8 into the manifold (clean to dirty) rather than the other way around. I made sure that the clean room at BSC8 would overpower the clean room at the spool piece, where the Y manifold was open, driving air into BSC8 from its clean room and down the manifold to the opening at the spool. To do this, I turned off the purge air, had the C3 removed from over the BSC8 ISI, removed the C3 from the manifold opening and pulled aside some of the clean room curtains there to reduce pressure in the clean room at the spool. Previous experiments had shown that this produced a good air flow from BSC8 into the manifold and out at the spool.  Most of the air was coming in through the BSC8 dome opening so I checked the particulate level, finding under 50/ft^3 inside BSC8, even when a person was on the upper level working on the ISI.

Immediately after installation we carried the railing down the manifold, and I measured particle levels of about 50/ft^3 in BSC8 as Art walked down the manifold.

Figure 4 is a photo of the inside bottom surface of the baffle, showing a few dust particles. This surface is quite close to the test mass and may be a good witness plate to monitor accumulation of dust. I think we should photograph it again when we button up.

Robert S., Lisa A., Scott S., Art R., Manuel R., Thomas V., Jodi F., Chris K.

Images attached to this report
H2 AOS
douglas.cook@LIGO.ORG - posted 15:47, Thursday 19 January 2012 - last comment - 16:40, Thursday 19 January 2012(2069)
H2 ITMy suspension initial alignment and the ACB centering
(Doug, Travis, Hugh, Annamaria, Jason)

The final pointing is PITCH ~ 9uradians to the required beam line
                      Yaw ~ 10 uradians to the required beam line

Having the Cartridge alignments and the GAP/parallel alignments accuracies close was very useful as the laser collimator return reflection was swinging through when the optic was released from the EQ stops.

Tightening the setscrews on the pitch adjuster screws influenced the pitch pointing by ~ 150 uradians.

Care must be taken to determine the HR reflection from the AR reflection.

One full turn of the sus pitch adjuster = about 400urads of pitch change.

1/4 turn of the static ISI adjusters = about 240 urads. This was done by tightening one sid and loosening the opposite and working through the 8 adjusters.

The arm cavity baffle alignment visually as seen through the theodolite is well centered. The baffle apurature is not perfectly round and so I averaged the gap about the ITMy. Previous measurements from the corner cube gave us a quantitative number for its location. The pusher assembly needs to be removed yet.

In the end all went well, but patience is needed and damping ring down takes 15 minutes or so to see the readout.
Comments related to this report
travis.sadecki@LIGO.ORG - 16:40, Thursday 19 January 2012 (2070)

Just a clarification of Doug's statement that "One full turn of the sus pitch adjuster = about 400urads of pitch change.".  This is a result of a measurement taken by Jason (he might be able to give a more accurate figure, but this is what stuck in my head, and either way, is just a approximate figure for use by those tuning the suspensions) on ITMy during coarse pitch adjustment after welding.  A more accurate statement would be "One full turn of both pitch adjusters on the UIM yield about 400 uradians of pitch".  We have not used the Top Mass fine pitch adjusters for much of the real "fine" pitch due to the fact that the upper one is inaccessible once the tablecloth for the OSEMs is installed.  Perhaps we should consider modifying the tablecloth plates to allow access to these adjusters (specifically the top one) as using only the UIM stage adjusters may be less than ideal (those with Matlab/Mathematica mastery could speak to this better).

H1 PSL
robert.schofield@LIGO.ORG - posted 18:34, Wednesday 18 January 2012 (2068)
H1 PSL table motion passes test

We installed the H1 PSL table using our standard epoxy float technique here. The plot shows a comparison of the H1 table to the H2 table, installed in the spring. The lowest resonant frequencies are about where we want them.

Robert S., Rick S., Michael R., Bubba G.

Non-image files attached to this report
H2 SUS
travis.sadecki@LIGO.ORG - posted 17:41, Wednesday 18 January 2012 (2067)
Reaction chain attached to ETMy upper structure

A. Effler, G. Moreno, T. Sadecki

After yesterday's reapplication of First Contact on the ready-to-be-attached ETMy reaction chain, I peeled the new FC from the AR face of the ETM and cleaned up the edges with acetone.  Satisfied with the cleaner appearance, we began the delicate process of mounting the reaction chain next to the main chain on the upper structure.  With the assistance of the highly useful 5-axis table, and the keen eyes of Gerardo and Anamaria, the mating went smoothly.  Due to adverse weather, we decided that this is as far as the ETMy would progress today.  Currently it is attached to the US, but the wires between the Top Mass and the UIM still need to be attached in order to begin assessing alignment.  Also, the AOSEMs in the PenRe were removed to facilitate the mating by reducing interference with the flags, so these will need to be reinstalled and aligned before hanging the chain.  All in all, BSC6 is progressing, albeit slower than anticipated due to ongoing work on BSC8, travel of the installation team, and, now, weather.

Note: In spite of an attempt to locate the 'old-style' non-captive lower structure spacers, we wound up with one of the 'new-style' captive spacers with a non-captive, i.e. fully threaded, screw out of the 8 total spacers required.  We decided to see if it would work, and in so doing, decided to put in in the least intrusive place (the lowest, right hand position; it can be identified by looking at the backside of the screw opposite the head since we used a 2" spherical tip EQ stop screw) in case we desire to replace it in the future.  With a little help from a pair of needlenose pliers, we were satisfied that we were able to get it sufficiently tight.  Captive hardware for these is being ordered ASAP.

Images attached to this report
H2 SEI
hugh.radkins@LIGO.ORG - posted 16:17, Wednesday 18 January 2012 - last comment - 16:53, Wednesday 18 January 2012(2065)
Viton Added/Exchanged BSC8 ISI Vibration Absorbers
JimW MitchellR GregG Hugh

Greg & Mitchell Locked the ISI & used the crane to lift the four 150lb Keel Mass Stacks and placed eight 1x1x1/4"thk viton pads, two under each corner of the stack.

Meanwhile, Jim & I unbolted the six Optical Table Mass Stacks and replaced all the viton with approved material.  We also added a second metal washer under the shoulder of the Shoulder Screw to compress the viton a little less.  Now we'll see how those peaks look.

Since the ACB needs a little more tweking, we left the ISI locked.  HEPI remains unlocked.
Comments related to this report
greg.grabeel@LIGO.ORG - 16:53, Wednesday 18 January 2012 (2066)

A picture of the top masses on the viton pieces.

Images attached to this comment
H2 SEI
hugh.radkins@LIGO.ORG - posted 12:54, Wednesday 18 January 2012 (2064)
BSC8 HEPI State for Initial Alignment
As IAS told us last night we were 0.4mm South, we disconnected the Vertical Actuators and then based on the Dial Indicators moved a total of ~1/2mm North.  After this, IAS told us we were 0.9mm too far North...What gives?

Jason checked his numbers and confirmed.  We moved the HEPI back South ~1mm and now IAS says we are 0.03mm South.

So now the ACB is being aligned--when they are done, SEI will change/add Viton to vibration absorbers.
H2 SUS
betsy.weaver@LIGO.ORG - posted 12:00, Wednesday 18 January 2012 (2063)
BSC6 ETMy STatus
Bland, Sadecki
Yesterday, we worked towards attaching the lower reaction chain to the full QUAD.  We:

- Moved it to the 5-axis scissor lift
- Rerouted and secured the cables on this portion of the chain
- Maneuvered it under the ISI next to the main chain
- Pulled the FirstContact on the ERM HR surface (blew with filtered N2 and drag wiped residual ring around the edge near the ID of the gold coating)
- Pulled the FirstContact from the ETMy AR - found that there was sever streaking on the mass under the FC at the top 3 inches of the sheeting, as well as a smear of FC on centerline, right 3". <- Awww, game over.
- Repainted on new FC sheet with PEEK tab.
- Left it overnight to dry since it was so late in the day.

So, unfortunately we could not get the chain attached due to the FC process.
LHO General
david.barker@LIGO.ORG - posted 10:58, Wednesday 18 January 2012 (2062)
Control room and msr upgrade status

Photo shows that all racks other than the fibre opitcs patch rack have been removed from the MSR and the UPS rack is disconnected from the power circuits at the moment. Underfloor power upgrades are complete. We are still pulling out the old underfloor CDS cabling, carefully while maintaining active systems. A new cable tray has been installed under the floor which cuts across the centre of the main loop. Underfloor drawing is available on DCC 

<A HREF="https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=78581"> Link to D1200078</A>

Images attached to this report
H2 SUS
anamaria.effler@LIGO.ORG - posted 18:44, Tuesday 17 January 2012 - last comment - 09:18, Wednesday 18 January 2012(2060)
H2 ETMY Software
Betsy, Richard, JeffG, Anamaria

ETMY now has an iMac work station near the clean room.

The electronics chain will hopefully be closed tomorrow, once the feedthrough has been cleaned (to my knowledge the last piece missing).

The models are running on the front end, h2susetmy. We've loaded the filters and epics values necessary (using the load_medm_values and prepare scripts in SusSVN), so it *should* all be ok. In order to fix previously mentioned issues of sign flip and dc gain, we've entered dumb OSEM input filters by hand as a simple zero at 10 Hz and pole at 4 Hz. When the scripts are fixed, we will rerun them to get in whatever filters we decide on. We also copied over the damping filters from ITMY, by hand. Had to change some filter bank gains to match production electronics.

Saved a burt file with today's date in /opt/rtcds/lho/h2/userapps/release/sus/h2/burtfiles/etmy/ and committed it to svn. Just in case. 
Comments related to this report
anamaria.effler@LIGO.ORG - 09:18, Wednesday 18 January 2012 (2061)
Typo: pole at 0.4 Hz not 4 Hz.
H2 SUS
travis.sadecki@LIGO.ORG - posted 16:31, Friday 13 January 2012 - last comment - 10:04, Tuesday 24 January 2012(2039)
Status of SUS in BSC8

After the ACB crew had finished their work in BSC8, I entered the chamber to unlock FMy.  So, until further update, the status of the suspensions is: ITMy is LOCKED, FMy is UNLOCKED.  I'll leave it to the ACB and SEI crews to independently report their status.

Comments related to this report
travis.sadecki@LIGO.ORG - 10:04, Tuesday 24 January 2012 (2076)

As of 19th Jan., both ITMy and FMy are UNLOCKED.  ITMy is aligned to IAS specs.  Some further adjustments to the OSEMs are coming soon to finalize these suspensions. 

Displaying reports 86261-86280 of 88268.Go to page Start 4310 4311 4312 4313 4314 4315 4316 4317 4318 End