Displaying reports 11981-12000 of 89162.Go to page Start 596 597 598 599 600 601 602 603 604 End
Reports until 09:18, Wednesday 07 August 2024
H1 CDS
david.barker@LIGO.ORG - posted 09:18, Wednesday 07 August 2024 - last comment - 09:18, Wednesday 07 August 2024(79493)
Dolphin Card Temperatures

Following from the airflow changes yesterday at the end station Adnaco chassis, the h1cdsrfm cards have maintained their new temps of (ey, ex, cs) = (64C,75C,61C).

Scanning all the cards this morning, their temps are in the range 61C to 79C (full list below).

61C = h1cdsrfm,h1omc0

79C = h1seib2,h1seih45

 

Comments related to this report
david.barker@LIGO.ORG - 09:18, Wednesday 07 August 2024 (79494)

h1asc0.txt: 65C
h1cdsh8.txt: 72C
h1cdsrfm.txt: 64C
h1cdsrfm.txt: 75C
h1cdsrfm.txt: 61C
h1iscex.txt: 72C
h1iscey.txt: 71C
h1lsc0.txt: 64C
h1oaf0.txt: 63C
h1omc0.txt: 61C
h1seib1.txt: 72C
h1seib2.txt: 79C
h1seib3.txt: 74C
h1seiex.txt: 71C
h1seiey.txt: 70C
h1seih16.txt: 74C
h1seih23.txt: 71C
h1seih45.txt: 79C
h1seih7.txt: 74C
h1susb123.txt: 72C
h1susex.txt: 66C
h1susey.txt: 71C
h1sush2a.txt: 66C
h1sush2b.txt: 72C
h1sush34.txt: 72C
h1sush56.txt: 66C
h1sush7.txt: 65C
 

H1 TCS (TCS)
corey.gray@LIGO.ORG - posted 08:43, Wednesday 07 August 2024 (79492)
TCS Chiller Water Level Top-Off (Bi-Weekly, FAMIS #27795)

Addressed TCS Chillers (Wed [Aug7] 754-804am local) & CLOSED FAMIS #27795:

H1 PSL (PSL)
anthony.sanchez@LIGO.ORG - posted 08:36, Wednesday 07 August 2024 (79491)
PSL Status Report - Weekly

FAMIS: 26280
Laser Status:
    NPRO output power is 1.829W (nominal ~2W)
    AMP1 output power is 64.06W (nominal ~70W)
    AMP2 output power is 136.4W (nominal 135-140W)
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 28 days, 21 hr 1 minutes
    Reflected power = 19.8W
    Transmitted power = 107.1W
    PowerSum = 126.9W

FSS:
    It has been locked for 20 days 17 hr and 33 min
    TPD[V] = 0.6431V

ISS:
    The diffracted power is around 2.2%
    Last saturation event was 21 days 18 hours and 46 minutes ago


Possible Issues:
    AMP1 power is low
    PMC reflected power is high
    FSS TPD is low

LHO VE
david.barker@LIGO.ORG - posted 08:21, Wednesday 07 August 2024 (79490)
Wed CP1 Fill

Wed Aug 07 08:10:45 2024 INFO: Fill completed in 10min 41secs

Travis confirmed a good fill curbside.

Images attached to this report
H1 PEM
corey.gray@LIGO.ORG - posted 08:14, Wednesday 07 August 2024 - last comment - 12:19, Wednesday 07 August 2024(79489)
PSL102 Dust Monitor Looks Dead & Needs Power Cycle

Ran the Check_Dust_Monitor script and one of the PSL dust monitor is stuck at the same value & will need to be checked.

edit:  this is a KNOWN issue.  It's just that incursions into the PSL are somewhat rare & I had forgotten about this one.  This is a dust monitor in the anteroom--the dust monitor in the main PSL room is still operational.

Comments related to this report
jason.oberling@LIGO.ORG - 12:19, Wednesday 07 August 2024 (79498)

I went into the anteroom shortly after 19:00 UTC (12:00 PDT) and reset this dust monitor.  It came back to life and successfully completed a counting pass, so communication should be restored.

LHO General
corey.gray@LIGO.ORG - posted 07:41, Wednesday 07 August 2024 (79487)
Wed DAY Ops Transition

TITLE: 08/07 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
OUTGOING OPERATOR: n/a
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 4mph Gusts, 3mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.07 μm/s
QUICK SUMMARY:

Pumpdown of the Corner volume started last night---Janos just went out to continue Corner Pumping this morning.  (HAM7 also started to be pumped down yesterday.)

Les Guthman and film crew are here for day 2 of filming.

H1 CDS
david.barker@LIGO.ORG - posted 22:45, Tuesday 06 August 2024 (79486)
Instrument Air Pressure Trends added to ndscope trend web page

1,7 and 30 day trends of the INST AIR pressure signal can be viewed on the Ndscope Trend Web Page

1 Day

1 Week

1 Month

Images attached to this report
LHO VE
janos.csizmazia@LIGO.ORG - posted 19:30, Tuesday 06 August 2024 (79485)
8-6 vent vacuum diary
Today's activities:
- The relay tube was installed, and was leak checked: no leaks bigger than 1E-10 Torr have been detected
- The HAM5/HAM6 annulus system is being pumped down. The Turbo backing line is already at around ~4E-5 Torr
- The Mobile pumping station with 2 pcs. of ISP1000 pumping carts and with the mobile transformer has been installed next to the OMC Turbo station (see picture, and see the PID according to LIGO-E2300443-v1 Main volume Double Mobile Scroll Turbo Startup Procedure, Appendix II.)
- The checklist for pumpdown has been done according to LIGO-E2300169-v2
- The dew point at the OMC venting port in the chamber was measured -38.9 deg C, which is surprisingly good (details: https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=79483)
- The pumpdown of the corner has started. With the Double ISP-1000 carts it is pretty quick: the pumpdown started at 16:15, and at 19:07 the pressure is already 167 Torr, which means 1900 l/min (at the Turbo station, as the pressure is already <100, it is well over 2000 l/min, as it should be)
- The pumpdown of HAM7 has also started, it is pretty fast, as it was anticipated, since no doors were opened there. It is already at 1.2E-5 Torr. See details here: https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=79482

As you can see in both pictures, the HAM5-HAM6-HAM7 area is very busy with vacuum equipment, so please only go there if it is absolutely necessary, and if you do, be very careful. Especially the Pfeiffer pumping carts can tip over easily (remember last pumpdown), and in general, Turbo pumps don't like movement - they can easily trip off. Now there are 2 Pfeiffer pumping carts, 3 more small Pfeiffer turbos, a leak checker, a supersucker cart, the new double ISP-1000 mobile pumping station, and the HAM7 turbo up and running.

There were a couple of other issues, too:
- The PT-154 (MKS) gauge, between HAM7 and BSC3 on the FCT, falsely shows 1E-3 Torr. It needs replacement, which will be done after O4
- The instrument air compressor failed to switch on one more time at around 16:45. The aLog about the last failure is here: https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=79443. It was restarted with some struggle, but it seems that the only real solution is to replace it. A Nitrogen and a compressed air bottle was staged in the mechanical room, just in case
Images attached to this report
LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 19:22, Tuesday 06 August 2024 - last comment - 19:23, Tuesday 06 August 2024(79483)
Corner Station Dew Point Measurement

Dew point measurement taken this morning read at -43.7 oC. No demand on system, HAM5 and HAM6 all doors on.

Images attached to this report
Comments related to this report
gerardo.moreno@LIGO.ORG - 19:23, Tuesday 06 August 2024 (79484)VE

Blow down dew point measured at -38.9 oC before pump down started.

Images attached to this comment
LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 19:16, Tuesday 06 August 2024 - last comment - 16:43, Wednesday 07 August 2024(79482)
HAM7 Pump Down

HAM7 pump down went very smooth, no issues encountered during this process.

Blowdown dew point measurement was at -40.0 oC.

Pump down cart, SS500, was set to manage the pump down, now that the turbo pump is on, the cart can manage the selenoid valves in case of an emergency.

Pressure at HAM7 is 1.19X10-05 Torr.

Images attached to this report
Comments related to this report
gerardo.moreno@LIGO.ORG - 16:43, Wednesday 07 August 2024 (79501)VE

HAM7 1 day pump down trend.

Images attached to this comment
H1 CDS
erik.vonreis@LIGO.ORG - posted 17:56, Tuesday 06 August 2024 - last comment - 09:46, Wednesday 07 August 2024(79479)
Nuc28 now showing air pressure

In response to recent failures of the air compressor that's holding open some of the gate valves:

There's now a 6-hour trend of the air pressure on the lower left corner of the top screen for nuc28.

If the compressor is working, there should be a saw tooth pattern between 60 and 85 PSI, at 90+ minutes per tooth. 

When the pressure drops below 40, the pneumatic gate valves are in danger of closing.

Comments related to this report
jonathan.hanks@LIGO.ORG - 18:00, Tuesday 06 August 2024 (79480)
This can be seen on the lhocds screen shots page at (it updates regularly):

https://lhocds.ligo-wa.caltech.edu/cr_screens/png/nuc28-1.png

It is on the 'lock clock' section of the main screen shots page:

https://lhocds.ligo-wa.caltech.edu/cr_screens/

These both require credentials to access.
david.barker@LIGO.ORG - 09:46, Wednesday 07 August 2024 (79495)

The control room reported visibility issues with the dark color scheme (blue on black). I have changed it to blue on white and thickened the line.

NUC28

LHO General
corey.gray@LIGO.ORG - posted 16:39, Tuesday 06 August 2024 (79466)
Tues DAY Ops Summary

TITLE: 08/06 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: n/a
SHIFT SUMMARY:
Big DARPA tour, Relay Tube was installed, and other prep work for pumping down, and then Les Guthman did some filming work.

LOG:

H1 CDS
david.barker@LIGO.ORG - posted 16:10, Tuesday 06 August 2024 - last comment - 16:16, Tuesday 06 August 2024(79477)
Reducing end station Dolphin card temps by redirecting airflow

EJ, Marc, Jonathan, Erik, Dave:

EJ noted that the Dolphin PCIe cards located at the endstations and read out by h1cdsrfm in the corner are running much warmer than the rest of the Dolphin cards.

h1cdsrfm has 3 Dophin IX cards on its PCI bus, one is plugged into its local PCIe bank, the other two are in Adnaco expansion chassis which are located at the end stations, and are accessed by a 4km single mode fiber link connected to local adnaco adapter cards.

The local Dolhin card, cooled by h1cdsrfm's fans, runs at 62C. The EY card runs at 74C and the EX card runs at 90C. The end station temps are significantly higher than the manufacturer's recommendation.

The Adnaco expansion chassis were inspected at both end stations:

   both chassis side mounted, resting on a shelf

  both chassis have their cover installed

  both chassis fan is operational

The only difference between the two end stations is the PCIe slot the Dolphin card is installed in. At EY (74C) it is in the slot closest to the fan (closest to center of chassis), at EX (90C) it is the slot furthest from the fan (closest to the edge of chassis).

The chassis has one airflow outlet, the fan itself blowing outwards at the rear. There are several airflow inlets: circular hole pattern on top lid, center of the chassis; rectangular hole pattern on top lid, directly above the four PCIe slots; series of slots on left side, from front of chassis to half way back; ditto on right side.

At 14:06 at EY we put a plate on the top lid which blocks the circular hole pattern. Now air comes in from the holes directly above the PCIe slots, and the left and right slot array. This cooled the Dolphin card down from 74C to 65C in 30mins.

At 15:00 at EX we put a plate on the circular pattern, and blocked the right side slot array with tape. Now input air is directly above the PCI connectors and on the left side array only (the one closest to the cards)

Attached trend shows EX and EY temps over this period, started with 90C,74C and now at a steady 76C,66C

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 16:16, Tuesday 06 August 2024 (79478)

Photo of EX chassis after modification. Note black metal plate on top lid, which is blocking the circular hole pattern, and the black electrical tape down the right side blocking the array of rectangular slots.

Images attached to this comment
H1 ISC (ISC)
marc.pirello@LIGO.ORG - posted 15:30, Tuesday 06 August 2024 (79476)
HV Bypass Removed (power off) Ham 6, Ham 7, ESD.

We removed the high voltage bypass which turns off the high voltage power to Ham 6, Ham 7, and the ESD drivers to prepare for pumpdown.

Janos, Marc, Richard

H1 CAL
anthony.sanchez@LIGO.ORG - posted 13:42, Tuesday 06 August 2024 (79475)
PCAL EY Laser Shutter motor died, repaired, reinstalled.

The PCAL End Y Shutter stopped working.
I had Fil check it out and he simply replaced the shutter motor with RS Pro part number 238-9709.
Fil showed me how to replace the motors that go bad in them.
I went out to EY to replace the shutter today, ran a few functionality tests for local operation and remote opperation. It is working well.
Closing FRS ticket 31730

H1 SEI (SEI)
corey.gray@LIGO.ORG - posted 10:49, Tuesday 06 August 2024 (79474)
H1 ISI CPS Noise Spectra Check - Weekly (Famis 26003)

FAMIS Link:  26003

Only CPS channels which looks higher at high frequencies (see attached) would be:

  1. ITMx St1 V1
  2. ITMy St1 V2
  3. ETMy St1 H2 (my first time seeing this one)
Non-image files attached to this report
LHO VE (ISC, VE)
gerardo.moreno@LIGO.ORG - posted 15:01, Monday 29 July 2024 - last comment - 18:50, Tuesday 06 August 2024(79352)
GV5 Went From Soft Close to Hard Close Over The Weekend

Noticed that GV5 had hard closed on Saturday at 19:59 utc time, no human intervention.  It appears as if the instrument air pressure left for soft close GV5 was enough to hard close it.  According to PEM instruments near GV5 made lots of noise, see attached plot, accelerometer and microphone data.

I checked the dial on the gauge to measure the instrument air at GV5, and indeed there was only about 10 psi, this value is within the "usual" pressure used for soft clossing pneumatic gate valves and per procedure.

No interaction is required at this moment from the vacuum team.

Tagging ISC, since sensitive equipment is hanging near this gate valve, like cameras and OpLevs.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 11:15, Tuesday 30 July 2024 (79364)

I converted this microphone DQ signal to an audio wav file. The microphone saturates at +/-32768 for a fraction of a second, but you can hear the echo fade away after this.

Non-image files attached to this comment
david.barker@LIGO.ORG - 13:53, Tuesday 30 July 2024 (79365)

Here is the accelerometer as a wav audio:

(new file added at 13:52, orig file was created using the incorrect frequency of 16kHz, this is actually a 8kHz channel)

Non-image files attached to this comment
camilla.compton@LIGO.ORG - 15:24, Monday 05 August 2024 (79459)ISC

The ITMY Oplev (aligned at the time) didn't see this hard close, plot attached. 

Images attached to this comment
gerardo.moreno@LIGO.ORG - 18:50, Tuesday 06 August 2024 (79481)VE

Remember GV1 is closed, this makes ITMY Oplev blind, Sum on trend above is very small.

Displaying reports 11981-12000 of 89162.Go to page Start 596 597 598 599 600 601 602 603 604 End