The BS OPLEV is glitching mostly in PIT (a few in YAW but nowhere near as many) but this doesn't seem to be new behavior, Its been going on for at least the past year from the ndscope.
This may not have been a great trend, the glitches seen may just be the kicks from losing lock.
Looks like LVEA10 Dust Monitor temperature sensor starting working again at 03:40 PST this morning (it had failed 12:15 Tuesday). Tagging PEM.
Since we swapped the CO2X chiller for a new chiller 24 Oct 73704 (2nd t-cursor), the CO2X chiller has unlocked around once per week, mainly on Tuesdays and although is still decreasing in power, appears a lot more stable, plot attached.
The CO2X laser power really stopped unlocking and decreasing after the unlock 10 Oct (1st t-cursor), on this day we swapped the HWS SLEDs (shouldnn't effect CO2's but is in same rack as CO2X) and both CO2 lasers tripped off (there was Beckhoff OM2 work).
TITLE: 12/01 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Microseism
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 4mph Gusts, 2mph 5min avg
Primary useism: 0.06 μm/s
Secondary useism: 0.57 μm/s
QUICK SUMMARY:
PSL Dust Mon Alerting when I arrived.
ISC_Lock is in Idle The MicroSeism has been very high.
I'm going to try to Lock the IFO.
TITLE: 12/01 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Microseism
INCOMING OPERATOR: N/A
SHIFT SUMMARY:
H1 has been unable to lock for the entirety of the shift due to the high microseism. We tried to lock at around 01:20 with a slightly different seismic configuration, but to no avail.
H1 remains in 'IDLE'.
LOG:
No log for this shift.
H1 is still down from very high microseism, and it doesn't look to be coming down at all. The wind speeds have come up slightly as well; nothing above 10mph gusts though.
Tried locking with a slightly different CPS FF seismic configuration at Jim's recommendation a couple of hours ago, but still couldn't get past LOCKING_ALS.
Been snowing on site for the past few hours, first of the season!
Our high microseisms are, I think, typically produced by storm waves and their reflections off of the nearby coast or, less often, from the global microseism generating regions near Greenland or the Aleutian islands. We can distinguish between these by matching the wave periods in global maps to the microseismic peak frequency that we detect, and by the propagation direction. When the dominant microseism is from our coast, it affects the two arms about equally, when it is from the Aleutian island region it travels down the X-arm and there is little relative motion along the Y-arm, and when, like today, it is from the region near Greenland, it travels along the Y-arm and there is little relative motion between the stations on the X-arm. I wonder if the lack of relative motion along one of the arms could be used to improve our performance during these periods... The figure shows today's spectra from our 5 stations and the phase delays between the corner and out-stations, as well as maps estimating the wave height and wave period for today.
Wave models: https://mag.ncep.noaa.gov/model-guidance-model-parameter.php?group=Model%20Guidance&model=GEFS-WAVE&area=ATL-PAC&ps=area
[Aidan, Marie, Camille]
We measured the change in curvature of the PSAMS as a function of applied PZT voltage and applied preload torque. The measured defocus is the total defocus accumulated upon reflection.
The relevant values are:
During the measurement of the torque values, we think we shifted/bumped the stage at one point which introduced an offset into the measurements, but did not change the slope of defocus vs torque.
The PSAMS was measured by illuminating it with a 520nm collimated green laser, then using a 1:1 image relay telescope (f1 = f2 = 500mm) to put a conjugate plane of the PSAMS surface onto the HWS. The HWS then measured changes in the incident curvature.
The data is attached in a zip file with an Jupyter notebook for doing the analysis. Data is stored in 4 columns:
# Preload (in-lb), Voltage (V), X-Defocus (D), Y-Defocus(D)
Defocus vs PZT voltage
Defocus vs Preload Torque
ASC loops at three times are compared are below in DTT, all 0-232Hz, 0.05Hz BW with 50 averages and 45% overlap for ~ 8 minutes of data used. Good DARM: 2023/11/23 6:45UTC; Fuzzy Darm: 2023/11/23 7:15UTC; Bad Low Freq DARM: 2023/11/30 7:45UTC (useism high) range 140MPc.
Reused Jenne's 64760 rubbing script for these loops with 10minutes of data. PDFs attached. Comparing to 2023/11/23 6:45UTC good DARM time:
Because I just picked a time with a glitch, I compared CHARD in the lock before Tuesday maintenance 11/28 08:58UTC and the lock after 11/29 06:37UTC, You can clearly see the 1.1 and 3.4Hz peaks increase, plot.
Interestingly, there is a peak at 10.8Hz that wasn't there on the 23rd before or after the DARM fuzziness started but was there on 11/28 before maintenance started see zoomed plot.
Rahul didn't see anything strange on the quads in 74503, but I think that measurement is taken with damping off. Tagging SUS.
Sheila noted that the 3.3Hz peak isn't visible from the top mass (won't show in Ryan's 74522). Looking at the Quad L2 witness channels when we are unlocked, there is no difference before and after Tuesday maintenance, no features above 3Hz, plot attached.
When we are locked, the 1.1 and 3.4Hz features are visible in all quads in the lock after Tuesday maintenance, but not the lock before , plot attached.
This is a plot that shows the same times as Camilla's above, plotting the R0 L2DAMP IN signals which are the same signals as L2 WIT. This plot suggests that the extra motion 1.1 at 3.3 Hz is worse for ITMY than ITMX. (This is pretty much the same as Camilla's plot, but with the ITMs plotted on top of each other).
TITLE: 11/30 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Microseism
OUTGOING OPERATOR: Ibrahim
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 3mph Gusts, 2mph 5min avg
Primary useism: 0.30 μm/s
Secondary useism: 1.40 μm/s
QUICK SUMMARY:
H1 is down and ISC_LOCK in 'IDLE' due to very high microseism. If by some miracle it comes down during my shift, I'll attempt to lock.
TITLE: 11/30 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Microseism
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:
IFO is in IDLE due to high microseism impeding lock.
Secondary microseism is ~10x higher than nominal (likely due to 40ft waves off the Greenland coast). Primary microseism is getting worse due to bleeding from the secondary microseism. Picket fence also seeing this same elevated bleeding (intermittently).
There have been continued investigations into locking issues/locklosses/range instability from yesterday:
Other:
Since we're in IDLE due to the microseism, there's no active testing on these investigations. Once the shaking earth decides to cooperate, we will attempt to relock and look out for these potential instability, poor range, poor lock causes.
LOG:
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 17:49 | SUS | Randy | EX, EY | N | Genie lift stuff | 18:35 |
| 19:37 | SUS | Rahul, RyanC | CR | n | ITMY meas. | 19:57 |
| 19:37 | FAC | Tyler, contractor | Carpenter shop | n | Contractor work | 22:37 |
| 20:48 | SUS | Randy | LVEA | N | Looking at HAM3 for a sec | 20:57 |
| 23:14 | VAC | Gerardo | FCTE | N | VAC work | 23:57 |
I ran Jenne's rubbing script using a reference time of us being in DOWN on the 22nd before the fuzziness started on the 23rd around 07:00UTC and a check time of 10:00UTC on the 23rd while also in DOWN, I didn't really see anything noteworthy, some noise increase in the 0.1Hz area (microseism)?
I also ran using the same reference time against a time this morning and there was a couple of suspensions that looked interesting, there were some spikes in the 1.0 - 10 Hz bandwidth for PR2, PR3, PRM, SR3, SR2, MC3, MC1, and OM3. In the 0.0 - 1.0 bandwidth the Quads saw an increase in noise, specifically the ITMs, TMSs, and ETMY. SRM and SR2 have some large spikes just under 1 Hz. The ITMs temperature has slightly increased, ~ 0.25 - 0.3 degrees F but these changes are less than 0.5 degrees so its probably not a worry.
Later in the day I ran the script a 3rd time using a time from yesterday (13:54UTC 11/29) with the same reference from the 22nd and most of the features I saw are no longer there, except for ITMX. Maybe the time I chose earlier was just a bad time?
I checked the ISI motion on the ITMs, and ETMs using the BLEND GS13 channels. I also took a spectra of SRM and SR2. They all pretty much look as they did a month ago except SR2s low frequency noise is higher, 0.1 Hz and below.
I took raw osem spectra of all four QUADs (the 0.45Hz peak seen over here is a suspension mode - reference shown here) and Beam splitter and they look fine - please see the screenshot attached below. The measurements were taken when the IFO was in DOWN state.
Since we had time (like 5-10mins), I also took a quick transfer function measurements on ITMY - P (F1, F2, F3 BOSEM), T (SD BOSEM), V(LF, RTBOSEM) dof and they look healthy. ITMY has been restored to its nominal state after the measurements were complete.
Ibrahim is now trying to lock the IFO.
Since Jenne was concerned about SRM, SR2, SR3 and OM3 based on Ryan's plot above, I took raw osem spectra of the same and they look fine to me - see plot attached below. OM3 has a small peak at 2.28 Hz and at 40Hz approximately - which I am currently investigating by going back in time (update - similar features also visible when I run these measurements three weeks back in time).
I used dtt to reproduce Ryan's plot for SR2 using the gps times in his second pdf attachment. Looking at the DAMP in signals this reproduces Ryan's result. Looking at the individual osem signals (right colum plots), it looks like the problem is mostly visible in LF and RT osems.
Looking at a time series of the time from Ryan's second attachment, that is just a few seconds after a lockloss. So the alarming things that we are seeing are just ring downs of the lockloss transient.
I looked into the two locklosses from November 29th, 01:39UTC and 04:25UTC from during the time where the AS72 Gain was increased from 12dB to 21dB (74457), before it was reverted due to potentially having caused the next two locklosses.
It doesn't seem to me that both locklosses had the same cause, since there seems to be some discrepencies between the two locks as well as between the actual locklosses. Based on looking through the lockloss ndscopes, it looks like the first lockloss was probably caused by the AS72 gain, but I don't think the second one was, or at least wasn't the only cause. Here's a quick breakdown of some differences:
ASC Loops (ASC-01:39UTC, ASC-04:25UTC)
01:39 Lockloss - Signals look normal up to lockloss
04:25 Lockloss - Many signals are much larger than during the previous lock, and some are increasing in the last ~10s in the INMON channel.
LSC Loops (LSC-01:39UTC, LSC-04:25UTC)
01:39 Lockloss - LSC loops look much different than usual
04:25 Lockloss - Loops look pretty normal
SUS MASTER_OUTs (SUS-bothtimes, SUS-01:39UTC, SUS-04:25UTC)
01:39 Lockloss - MASTER_OUT channel values are more or less stable once in NOMINAL_LOW_NOISE
04:25 Lockloss - During last ~15minutes of lock, many MASTER_OUT values double and stay that large up to the lockloss
Sheila, Oli
I was looking for any overflows from AS72 before the locklosses, and there were none, seen here (01:39UTC, 04:25UTC; zoomed out for the sake of better viewing, but I found the time of lockloss using AS_A_NSUM_OUT while zoomed in). The rise in Accumulated Overflows doesn't actually happen until after the locklosses, which is normal.
So we can maybe say that the increase in the AS72 gain was not the cause of these two locklosses.
An extra small note about the 04:25UTC lockloss: Regular oscillations can be seen(ndscope) on ASC-AS_A_NSUM_OUT starting -9s until LL and on LSC-PR_GAIN_OUT starting -11s until LL.
IFO is locking.
Difficulties with microseism locking persist (haven't been able to lock PRMI yet).
We stayed in idle for a bit to allow people to take some measurements (and also while Robert was near the BRS).
Just started our hopefully valiant second attempt.
Addressed TCS Chillers (Wed [Nov29] 415-430pm local) & CLOSED FAMIS #26162: