TITLE: 08/23 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 150Mpc
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: Uneventful and quiet night. Detector in Observing and Locked for 9hrs 40mins. Dust is finally settling down in the PSL, and our range is creeping back up as compared to the start of my shift.
23:00UTC Start of shift - detector in Observing and Locked for 1.5 hours
23:03 Superevent S230822bm
LOG:
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 23:23 | CDS | Jonathon, Ajay | n | Turn on DMT | 23:35 |
Previously done in 72264
Closes FAMIS#25080
No In-Lock SUS Charge measurements were made this morning due to the SUS_CHARGE Guardian having been in the DOWN state since last Tuesday 8/15 15:29UTC. TJ had fixed up some errors in the SUS_CHARGE code (72219) and had placed it in DOWN for Tuesday Maintainance but had forgotten it there.
At 3:56UTC I put the Guardian back into the correct WAITING state by selecting INJECTIONS_COMPLETE, as done in 71067.
We are still in Observing and have been Locked for 5hrs 40mins now.
All the dust monitors that have had high dust counts from Tuesday Maintainance are going down, with the exception of both the >300um and >500um counts in the PSL Laser Room, of which the >300um counts is at the second highest it's been in 7ish years (highest it's been in the last ~7 years was two weeks ago). This rise in dust looks like it could be related to the wind at the corner station, so I'll keep an eye on it and hopefully it'll come down as the wind dies down.
TITLE: 08/22 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 141Mpc
INCOMING OPERATOR: Oli
SHIFT SUMMARY:
Lock#1:
Yarm locked at a low power (~75%, lower power than XARm) and oscillating, no flashes at DRMI or PRMI, CHECK_MICH lockloss. There was a few more LL at FIND_IR and LOCKING ALS so I did an Initial Alignment, which went well untill we got to SRC where it tried for a while then eventually gave me a message "find by hand" where I tapped on SRM in Pitch maybe 10 microradians to maximize the signal and it was enough to push it onwords and finish IA.
Yarm looked better after the IA but was still oscillating, during these troubles the Norco liquid nitrogen truck was filling CP1 but we weren't seeing any extra motion on the CS accelerometers that we looked at.
Reached NLN at 21:25UTC, I had some sus SDF diffs pop up, they were all TRAMPs so I accepted them on SUSTMSX & SUSETMX. The 102Hz peak was noticable at the start of the lock.
In Observing at 21:45UTC, our range is lower now this lock
LOG:
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 14:57 | PCAL | Tony, Rick | EndX | Y | PCAL measurement | 18:56 |
| 14:59 | FAC | Chris | Mech room | N | Fan room1 | 15:19 |
| 15:00 | FAC | Karen | EndY | N | Tech clean | 16:23 |
| 15:01 | FAC | Cindy | FCES | N | Tech clean | 16:20 |
| 15:04 | EE | Ken | MidX | N | Light fixtures | 21:54 |
| 15:17 | FAC | Mitch | West bay | N | Parts dropoff | 19:55 |
| 15:29 | FAC | Chris | Bake lab | N | Check out fume hood for removal | 15:44 |
| 15:37 | DAQ | Dave | remote | n | restart nds1 | 19:24 |
| 15:49 | FAC | Chris | MidX | N | Bring Ken a scissor lift | 16:43 |
| 15:49 | PSL | Jason | PSL Anteroom | LOCAL | Inventory | 17:48 |
| 15:53 | SQZ | Vicky | Remote | N | SQZ maintenance | 17:50 |
| 16:09 | EE | Fill | LVEA | N | Wiring | 17:24 |
| 16:28 | VAC | Janos, Travis | EndY, LVEA | N | Measurements | 18:31 |
| 16:36 | EE | Marc | CER | N | Check out power supplies with lasers | 16:51 |
| 16:38 | FAC | Cindy | LVEA | N | Tech clean | 18:41 |
| 16:39 | SEI | Jim | CR | N | HAM8 transfer functions, HAM7 | 18:23 |
| 16:55 | FAC | Mitch, Ibrahim | Staging, Enclosure | N | Move laser blinds | 19:24 |
| 16:50 | FAC | Karen | LVEA | N | Tech clean | 18:20 |
| 16:58 | FAC | Chris | LVEA | N | FAMIS checks | 17:23 |
| 17:24 | FAC | Chris | FCES | N | FAMIS checks | 17:47 |
| 17:26 | EE | Fil | EndY, then EndX | N | ESD upgrade checks | 19:05 |
| 18:29 | FAC | Karen | EndY | N | Drop off supplies | 18:56 |
| 18:41 | FAC | Cindy | High bay | N | Tech clean | 18:58 |
| 21:05 | VAC | Janos, Travis | EndX | N | Investigate anulus pump | 21:30 |
| 21:09 | PCAL | Tony | PCAL lab | LOCAL | PCAL post end station work | 23:09 |
TITLE: 08/22 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 139Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 23mph Gusts, 19mph 5min avg
Primary useism: 0.09 μm/s
Secondary useism: 0.11 μm/s
QUICK SUMMARY:
Detector is in Observing and has been Locked for an hour and a half. Decently windy outside.
WP11361 TW1 raw minute trend file offload
Jonathan, Dave:
Last week the files were copied from the almost full SSD on h1daqtw1 to archive spinning media on h1ldasgw1. This morning I completed the transfer by reconfiguring nds1 to use the archive location, and then deleted the files from h1daqtw1's SSD RAID, reducing its usage from 97% to 4%. Jonathan made the nds1 configuration change permanent in puppet.
cdslogin reboot
Jonathan, Dave:
Jonathan rebooted cdslogin at 13:48. The CDS alarm and alert systems came back online with no problems.
Cable clean-up of the VMON channels for monitoring the ESD 18V and 48V power lines. Signals tied to the power lines through BNC bulkheads on the junction box (top of rack). Voltage divider boxes are installed in series. Signal routed through PEM test panel to AA chassis. See attached pictures. Will work with PEM group to see how we want to isolate the divider boxes and route cables.
Got a debrief from Fil on this -- his sentences can be interpreted as a bulleted list describing the *existing* system, not anything that he installed today. The only he did today was install a *new* BNC cable run from the VEAs' SUS-C1 to the CER TSC-C1 racks, without connecting them to anything and instead terminating both ends with 50 Ohm terminators.
I can expand on his words a bit to give the reader a better feel for the existing system:
"Cable clean-up of the VMON channels for monitoring the ESD 18V and 48V power lines."
He's investigated moving forward with clean-up of the voltage monitor channels that the PEM team uses to monitor the dedicated ESD low-voltage low-noise driver's +/-18V and +/-48V DC power input (see why under the last sentence below).
"Signals tied to the power lines through BNC bulkheads on the junction box (top of rack).
Signal routed through PEM test panel to AA chassis."
These voltage monitors are a BNC pick off from the power reduction "junction box" on the top of the end-station VEA SUS-R1 (EX/EY) field racks.
The LVLN ESD driver's power is *not* connected from the "standard" D1002189 power strips that are powering the rest of the chassis in SUS-R1.
- The dedicated / segregated power supplies live in the ante-room areas of the end-stations, in either DC power racks VDC-(X or Y)(C1 or C2). I don't have info on exactly where these live, so I can't be more specific.
The BNC monitor cables are sent to the PEM ADC via an overly complicated path:
(a) From the junction box to the 16ch BNC bulkhead PEM test patch panel (D1300779), in U41 of SUS-R1 (EX or EY)
(b) That SUS-R1 patch panel is connected via a long BNC cable run to an identical patch panel at U33 of the end-station CER TCS-C1 (XC1 or YC1) racks.
(c) Then more BNCs connect the TCS-(XC1/YC1) U33 patch panel to the 32ch 10x gain PEM AA chassis, D1001421, on in to the PEM/TCS IO Chassis.
Of perhaps interesting note, it's unclear and inconsistent as to what the voltage monitor signals are monitoring. At both end stations, there're only 2 monitor channels. Fil *thinks* that these are connected to only the positive legs of each voltage. At EX, it's clear from the junction box spigot labeling that this is connected to +18V and +48V. However, at EY, the spigots are labeled +18V and -18V. This deserves clarification.
"Voltage divider boxes are installed in series."
Out of the field of view of the pictures, in between the junction box and the BNC patch panel in SUS-R1, (a), there're metal project, aka pamona, boxes wrapped in ziploc baggies. These project boxes contain a voltage divider to gain down the voltage suitable for ingestion into one of our ADCs.
"Will work with PEM group to see how we want to isolate the divider boxes and route cables.
We can do better than metal project boxes in ziploc baggies to electrically isolate them from where they rest on the rack or each other. A simple upgrade would be to just use plastic project boxes.
The idea on the table with the new cable run that Fil installed today would be to go directly from the project boxes into the AA chassis, rather than connecting through the patch panel. This has the advantage of re-freeing up the patch panel for temporary tests, and making a rather important voltage monitor more permanent.
Attached are Fil's whiteboard sketch of the system -- highlighting the new long BNC cable run he pulled today between VEA SUS-R1 and CER TCS-C1 in blue.
Using Omnigraffle, the pictures Fil attaches in the main aLOG, and my knowledge of the system, I enhanced his whiteboard sketch into the attached cartoon.
While Ryan and I were testing out some ALS crystal frequency code, we noticed that if an ALS arm node goes into the Increase_Flashes state, it won't leave even if there are faults. I think I remember not putting in our usual fault checking decorators here because we want to make sure that we restore the offsets before leaving the state, and not just jump straight to the Fault state.
I ended up adding the general fault decorator the main method, since this will be before we set any of the offsets. I then just added a conditional in run to look for faults and then notify and wait. I chose to just wait rather than restore and then jump to Fault because the Beckhoff automation will often fix itself after some time and we don't want to be jumping in and out of this state. If we don't ever get out of this state, then IFO_NOTIFY will alert an operator and they can then intervene. This has been loaded into both ALS nodes.
WP 11349
Spare port on the CPS Fanout Chassis (SUS-R3) was used to synchronize the HAM7 CPS field chassis. Field cable was terminated with 100 ohm resistors across pins 1&6, 2&7. Temporary timing cable from HAM5 field box was disconnected.
Maintenance activities have finished and we are going to start relocking and do a quick ALS automation code test while relocking green arms.
Reaquired Observing at 21:45
Both Jeff and Stuart Aston separately noticed that the quad R0 alignment offsets are not engaged or disengaged via the guardian. This seems like an oversight and has created a bit of confusion (LLO FRS27877). I've added to the engage_align_offsets to also switch R0 offsets if R0 is present in the levels() list. I tested this out on a quad (ETMY) and a non-quad (PRM), both worked as expected.
def engage_align_offsets(onoff):
+ stages = [susobj.levels()[0]]
+ # Do R0 at the same time for quads
+ if 'R0' in susobj.levels():
+ stages += ['R0']
log('Ramping ALIGNMENT offsets %s' % (onoff))
- susobj.alignOffsetSwitchWrite(onoff, levels=[susobj.levels()[0]])
+ susobj.alignOffsetSwitchWrite(onoff, levels=stages)
I reloaded all suspension nodes and committed this change to the svn. I'll pass this on to Stuart to do at LLO when they get the chance.
Naoki noticed the pump fiber rejected PD (in ham7, rejects pump fiber light that comes out in the wrong polarization) was saturated, so today I re-aligned the pump fiber polarization using sqzt0 pico's (described recently also in 71761).
I'm not sure why pump fiber needs to have its input polarization readjusted so often; I checked the CLF fiber and FCGS fiber, and they both seemed relatively well-aligned despite having not adjusted those in a while. Especially this time, it seems the fiber polarization got misaligned more quickly than before.
Austin had to reset the sqz pump ISS again on Sunday (72474), lowering the generated sqz level by lowering OPO trans from 80uW (recent nominal) to 65uW. Sqz level correspondingly went down. Naoki and I have re-aligned the pump fiber polarization, and brought the squeezer back to the nominal 80uW generated sqz level.
It's strange that we had to re-align the pump fiber polarization, again. The pump fiber polarization seems to be misaligning more quickly recently, see trends. This time, the fiber polarization misaligned to saturation in 1-2 days (last time was several days, before that we never saw it misaligned to saturation). It also needed both the L/2 and L/4 waveplates to re-align it. We should definitely monitor this situation and see if we can understand/fix why it's happening.
Tue Aug 22 10:08:15 2023 INFO: Fill completed in 8min 11secs
Note TCs did not saturate at -200C, the outside temperatures are lower today.
TITLE: 08/22 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Preventative Maintenance
OUTGOING OPERATOR: Ibrahim
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 12mph Gusts, 7mph 5min avg
Primary useism: 0.01 μm/s
Secondary useism: 0.10 μm/s
QUICK SUMMARY: We're going to try and stay locked for a while this maintenance period, the BRS at EndX has been turned off for the PCAL team working down there.
TITLE: 08/21 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: H1 was able to relock and start observing an hour into the shift, then remained observing for the rest of the evening. H1 has now been locked for 7 hours.
The dust monitors for PSL101, EX VEA, and Optics Lab have been alarming on and off throughout the evening. Trends of counts attached.
LOG:
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 01:22 | CAL | Tony | PCal Lab | - | Preparing equipment | 01:41 |
State of H1: Observing at 152Mpc
H1 was able to relock automatically following the lockloss at the start of the shift. H1 has now been locked for 3.5 hours.
FAMIS 19990
The PMC and FSS alignment from last Tuesday (alog 72222) caused the expected drop in PMC_REFL power and increase in PMC_TRANS. The FSS_TPD signal didn't improve much with that tweak, but over the past 3 days it's risen by ~50mV. The ISS diffracted power is continuting to jump around as we've seen it do recently.
Naoki and I unmonitored H1:SQZ-FIBR_SERVO_COMGAIN and H1:SQZ-FIBR_SERVO_FASTGAIN from syscssqz observe.snap. They have been regularly taking us out of observing (72171) by changing when the TTFSS isn't really unlocking, see 71652. If the TTFSS really unlocks there will be other sdf diffs and the sqz guardians will unlock.
We still plan to investigate this further tomorrow. We can monitor if it keeps happening using the channels.
Daniel, Sheila
We looked at one of these incidents, to see what information we could get from the beckhoff error checking. The attached screenshot shows that when this happened on August 12th at 12:35 UTC, the beckhoff error code for the TTFSS was 2^20, counting down on the automated error screen (second attachment) the 20th error is Beatnote out of range of frequency comparator. We looked at the beatnote error epics channel, which does seem to be well within the tolerances. Daniel thinks that the error is happening faster than it can be recorded by epics. He proposes that we go into the beckhoff code and add a condition that the error condition has to be met for 0.1s before throwing the error.
In the last 5 days these channels would have taken us out of observing 13 times if they were still monitored, plot attached. Worryingly, 9 times in the last 14 hours, see attached.
Maybe something has changed in SQZ to make the TTFSS more sensitive. The IFO has been locked for 35 hours where sometimes we get close to the edges of our PZT ranges due to temperature drifts over long locks.
I wonder if the TTFSS 1611 PD is saturated as power from the PSL fiber has drifted. Trending RFMON and DC volts from the TTFSS PD, it looks like in the past 2-3 months, the green beatnote's demod RF MON has increased (its RF max is 7), while the bottom gray DC volts signal from the PD has flattened out around -2.3V. Also looks like the RF MON got noisier as the PD DC volts saturated.
This PD should see the 160 MHz beatnote between the PSL (via fiber) and SQZ laser (free space). From LHO:44546, it looks like this PD "normally" would have like 360uW on it, with 180uW from each arm. If we trust the PD calibrations, then current PD values report ~600uW total DC power on the 1611 PD (red), with 40uW transmitted from the PSL fiber (green trend). Pick-offs for the remaining sqz laser free-space path (iem sqz laser seed/LO PDs) don't see power changes, so unlikely the saturations are coming from upstream sqz laser alignment. Not sure if there's some PD calibration issues going on here. In any case, all fiber PDs seem to be off from their nominal values, consistent with their drifts in the past few months.
I adjusted the TTFSS waveplates on the PSL fiber path to bring the FIBR PDs closer to their nominal values, and at least so we're not saturing the 1611. TTFSS and squeezer locks seem to have come back fine. We can see if this helps the SDF issues at all.
These were re-monitored in 72679 after Daniel adjusted the SQZ Laser Diode Nominal Current, stopping this issue.