Displaying report 1-1 of 1.
Reports until 23:19, Sunday 24 August 2014
H1 ISC (ISC, SEI, SUS)
daniel.hoak@LIGO.ORG - posted 23:19, Sunday 24 August 2014 - last comment - 23:20, Sunday 24 August 2014(13580)
HAM6 closeout

Dan, Koji

This afternoon we completed the final remaining jobs before the doors go on HAM6:

Since we locked and unlocked the ISI, the seismic team may want to make a quick check in the morning that the table is floating freely.  (It's ok to turn up the purge air to keep the door covers from contacting the table.)

In the attached 'H1HTTS_ALL_Spectra' files, note that the difference between the July 18th measurements and today is the floating of the ISI.  Not sure if this accounts for the change in the spectrum (more noise below 2-3Hz, less noise above).

Non-image files attached to this report
Comments related to this report
daniel.hoak@LIGO.ORG - 23:20, Sunday 24 August 2014 (13581)

Images attached to this comment
Displaying report 1-1 of 1.