After resolving rubbing and magnet attachment issues on H1-SR3, we took phase 2b transfer functions and power spectra. There are small unmodeled peaks in yaw at 1.57Hz, in pitch at 1.06Hz, and in transvers at 1.06Hz, which are suppressed with damping. There is some of the environmental noise we have seen in the other suspensions tested on the same optics table in the LVEA. Overall H1-SR3 compares favorably other LOH and LLO HLTS suspensions. I have attached the plots below. All scripts and data files have been committed to the SVN repository.