Reports until 01:55, Friday 05 September 2014
H1 AOS
koji.arai@LIGO.ORG - posted 01:55, Friday 05 September 2014 (13767)
OMC scan follow up

Follow up analysis of the OMC scan by Dan (ALOG entry13660)

I believe this was done with a single bounce of ITMX.
ITMY had an oplev issue at the time as you can seen in https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=13654

Frequency calibration

Calibratre data points using 0th- to 3rd-order carrier resonances and 0th- and 2nd-order sideband resonances as a frequency reference

Interpolate the frequency calibration by 11th order polynomials (see attachment "OMC_mode_scan_freq_calib.pdf")

Mode identification

Once the frequency is calibrated, the modes can be identified. As the beam is not filtered, it contains all of the sidebands and the sidebands of the sidebands including their higher-order spatial modes. (Attachment "OMC_modes.png" or "OMC_modes.pdf")

In the figure "USB/LSBn" indicates nth-order higher-order mode for upper or lower sidebands for 45MHz modulation.
"usb/lsb" indicates upper or lower sidebands for 9MHz modulation.
"2xUSB0" and "2xUSB0" means 2nd-order modulation sidebands for the 45MHz modulation (i.e. 90MHz sidebands).

Peak fitting

Peak heights of most of the modes are fitted (by hand). (Attachment "OMC_scan_LHO.pdf")

The decomposition of the modes are listed at the end of this entry

Mode matching

From the mode decomposition, the mode matching of the carrier is 0.86 +/- 0.01

Modulation depth

From the ratio of the sideband photocurrent and the carrier photocurrent, the modulation depth for each modulation was estimated

Modulation depth for f1 (9MHz): 0.198+/- 0.006

Modulation depth for f2 (45MHz): 0.305+/-0.003
 


Carrier  
Order mA
0 13.13
1 0.088
2 1.65
3 0.028
4 0.25
5 0.012
6 0.07
7 0.008
8 0.018
   
Upper sidebands (45MHz)
Order mA
0 0.3105
1 0.0024
2 0.036
3 0.0004
4 0.005
   
Lower sidebands (45MHz)
Order mA
0 0.313
1 0.002
2 0.036
3 0.0004
4 0.0065
   
2nd order Upper sidebands (90MHz)
Order mA
0 0.0025
1 0.00002
2 0.00075
   
2nd order Lower sidebands (90MHz)
Order mA
0 0.0025
1 0.00002
2 0.00075
   
Upper sidebands (9MHz)
Order mA
0 0.13
1 0.001
2 0.015
3 0.0008
4 0.0035
   
Lower sidebands (9MHz)
Order mA
0 0.13
1 0.001
2 0.015
3 0.0008
4 0.0035
   
Sidebands of sidebands
(+/-9MHz+/-45MHz) mA
-54MHz 0.003
-36MHz 0.003
36MHz 0.003
54MHz

0.003

 

Carrier TEM00 13.13 mA
Carrier TEMnm 2.12 mA
Sideband   1.03 mA
       
Mode matching  0.86  
Images attached to this report
Non-image files attached to this report