Open loop measurements of ITMX ISI controls
Trying to get this in before the SEI T&C call. Pictures are from open loop measurements of ITMX. Foton pics are comparing T240 blends and X loops from ITMY and ITMY.
Images attached to this report
Comments related to this report
jim.warner@LIGO.ORG - 17:04, Tuesday 09 September 2014 (13843)
It looks like the blend filters installed at ITMX may be different. Using the plot_current_blends script, I looked at ITMY and ITMX. I need some help interpreting, but the complementarity plots don't all look the same.