MC1 TFs
Mark B.

I started Matlab TFs on MC1 at 16:18 PDT.
Comments related to this report
mark.barton@LIGO.ORG - 10:25, Wednesday 24 October 2012 (4513)
Mark B. 

Checked at 07:05 am 10/24. Successful undamped and damped runs with one minor imperfection: a tripped watchdog on L on the lowest frequency band for the damped TFs. Everything else looks healthy. 

Damping off spectrum segment: 1035129790
Damping on spectrum segment: 1035127990