Mark B.

Per alog 5200, starting DTT TFs on ITMy. Will do M0 and R0 in parallel.
Comments related to this report
mark.barton@LIGO.ORG - 14:47, Tuesday 22 January 2013 (5203)
Mark B.

Plots for both chains were very messy, especially in pitch, so Travis has gone out to hunt for interferences, with particular attention to the flags between the chains.
Non-image files attached to this comment
mark.barton@LIGO.ORG - 15:24, Tuesday 22 January 2013 (5204)
Mark B.

Travis found a UIM flag that wasn't clearly touching but was a bit close for comfort and corrected it, so I'm starting another round of TFs. I probably won't finish before quitting time in which case I'll continue in the morning.