Recently, we reported the results of the arm power measurement during a time with high-noise DARM to be around 330 kW (alog 58804).
However, later measurements did not confirm these results.
After some thought, 330 kW in the arms was impossible (with 40 W input).
We agreed with them too quickly when they agreed roughly with our "back of the envelope" calculations, which ran as follows:
Back of the envelope
--------------------
Input power on PRM: 39.2 W
Power recycling: 57.2
Arm gain: 265
Estimated arm power = 300 kW
The latest arm power measurements suggest an arm power closer to 261.0 +- 1.3 kW.
Full results are reported at the bottom of this alog.
Varun has upgraded the arm power measurement to use every segment of the two QPDs at the end of each arm (16 total TFs).
I've processed these measurements, removed TF bias by estimating the TF via the excitation, and found the weighted average of their results.
The fourth attachment shows the arm power estimate TF for just the Y-arm A QPD, to give the idea behind the estimate.
All results are the on LHO CDS machines at /ligo/gitcommon/labutils/arm_power_measurement/plots.
The code is committed at https://git.ligo.org/aligo_commissioning/labutils/-/tree/master/arm_power_measurement.
Coupled cavity
--------------
The issue with the back of the envelope above is the Arm gain number, which assumes perfect coupling of power into the IFO. We have to consider the coupled cavity, and the new lower arm losses.
Our current PRM transmission is 3.1%, and the ITM transmission 1.5%.
Given these parameters, and our measured PRG, our round-trip arm loss is 34 ppm.
Using the arm power, our round-trip arm loss is 46 ppm.
Using the estimated reflected power of 9% from alog 59058, the round-trip arm loss is 40 ppm.
These arm losses are remarkably low: Advanced LIGO design documents anticipated 75 ppm round-trip losses in e.g. DCC T1000298, Section 2.2.
PRM Transmission
----------------
Finally, for any of these given arm losses, it's clear that our PRM transmission is too high.
The PNG attached below indicates that if we assume 20 ppm single-testmass losses (yellow line), our reflected carrier is minimized for Tprm ~ 1.7%.
As it stands, ~9%, or 3.5 W, of our incident carrier light is promptly reflected.
If we do transition to a PRM with transmission 1.7%, it's possible that Parm = 305 kW could be achieved (with the same input power of 40 W).
The mathematica notebook is committed at https://git.ligo.org/aligo_commissioning/power_budget,
and also attached below.
New arm power results
---------------------
DARM/H1:ASC-X_TR_A_SEG1_OUT Arm Power Estimate = 258.649 +- 3.567 [kW]
DARM/H1:ASC-X_TR_A_SEG2_OUT Arm Power Estimate = 272.490 +- 7.995 [kW]
DARM/H1:ASC-X_TR_A_SEG3_OUT Arm Power Estimate = 265.565 +- 6.931 [kW]
DARM/H1:ASC-X_TR_A_SEG4_OUT Arm Power Estimate = 257.086 +- 5.114 [kW]
DARM/H1:ASC-X_TR_B_SEG1_OUT Arm Power Estimate = 262.114 +- 3.735 [kW]
DARM/H1:ASC-X_TR_B_SEG2_OUT Arm Power Estimate = 276.812 +- 5.655 [kW]
DARM/H1:ASC-X_TR_B_SEG3_OUT Arm Power Estimate = 274.728 +- 5.965 [kW]
DARM/H1:ASC-X_TR_B_SEG4_OUT Arm Power Estimate = 254.638 +- 3.776 [kW]
DARM/H1:ASC-Y_TR_A_SEG1_OUT Arm Power Estimate = 255.051 +- 4.339 [kW]
DARM/H1:ASC-Y_TR_A_SEG2_OUT Arm Power Estimate = 261.821 +- 4.145 [kW]
DARM/H1:ASC-Y_TR_A_SEG3_OUT Arm Power Estimate = 270.828 +- 4.383 [kW]
DARM/H1:ASC-Y_TR_A_SEG4_OUT Arm Power Estimate = 248.732 +- 5.074 [kW]
DARM/H1:ASC-Y_TR_B_SEG1_OUT Arm Power Estimate = 254.859 +- 4.259 [kW]
DARM/H1:ASC-Y_TR_B_SEG2_OUT Arm Power Estimate = 268.231 +- 5.189 [kW]
DARM/H1:ASC-Y_TR_B_SEG3_OUT Arm Power Estimate = 269.522 +- 3.745 [kW]
DARM/H1:ASC-Y_TR_B_SEG4_OUT Arm Power Estimate = 251.185 +- 3.503 [kW]
X Arm Power Estimate = 262.3 +- 1.7 [kW]
Y Arm Power Estimate = 259.9 +- 1.5 [kW]
References
----------
## DCC design documents
- Advanced LIGO Length Sensing and Control Final Design
- Arm Cavity Finesse for Advanced LIGO
- Advanced LIGO Systems Design
## papers
- Demonstration of light recycling in a Michelson interferometer with Fabry-Perot cavities
## alogs
Pre-O4 RF powers (alog 59058)