Displaying report 1-1 of 1.
Reports until 16:53, Thursday 07 August 2025
H1 SUS
oli.patane@LIGO.ORG - posted 16:53, Thursday 07 August 2025 (86253)
Master list of LHO satamp swap results

Firstly I am very sorry for the length of this alog

I needed to finish up the comparisons for the satamps that were swapped on Tuesday (86207), as well as rerun almost all of the other comparison damp regression plots for every suspension that has had its satamp swapped out for ECR E2400330, either with different times or with the loop suppression divided out. There were also multiple changes made to the damp_regression_compare.m file. So I've gone and done that, so here are the results in this master post. I will link to the old results when applicable. They are out of order as compared to when their satamps were swapped.

damp_regression_compare.m
Now creates a plot of the ratios, lists important IFO info, and saves some of the variables to a .mat file
found in /ligo/svncommon/SusSVN/sus/trunk/Common/MatlabTools/damp_regression_compare.m
newest version is r12583

Input
IM1
Results:
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM1/SAGM1/Results/allDampRegressCompare_H1SUSIM1_M1_NoiseComparison_1437330256vs1438626136-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM1/SAGM1/Results/allDampRegressCompare_H1SUSIM1_M1_1437330256vs1438626136-1200.mat
Data:
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM1/SAGM1/Data/dampRegress_H1SUSIM1_M1_1437330256_1200.mat
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM1/SAGM1/Data/dampRegress_H1SUSIM1_M1_1438626136_1200.mat
r12561

IM2
Results:

/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM2/SAGM1/Results/allDampRegressCompare_H1SUSIM2_M1_NoiseComparison_1437330256vs1438626136-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM2/SAGM1/Results/allDampRegressCompare_H1SUSIM2_M1_1437330256vs1438626136-1200.mat
Data:
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM2/SAGM1/Data/dampRegress_H1SUSIM2_M1_1437330256_1200.mat
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM2/SAGM1/Data/dampRegress_H1SUSIM2_M1_1438626136_1200.mat
r12562

IM3
Results:

/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM3/SAGM1/Results/allDampRegressCompare_H1SUSIM3_M1_NoiseComparison_1437330256vs1438626136-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM3/SAGM1/Results/allDampRegressCompare_H1SUSIM3_M1_1437330256vs1438626136-1200.mat
Data:
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM3/SAGM1/Data/dampRegress_H1SUSIM3_M1_1437330256_1200.mat
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM3/SAGM1/Data/dampRegress_H1SUSIM3_M1_1438626136_1200.mat
r12563

IM4
Results:

/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM4/SAGM1/Results/allDampRegressCompare_H1SUSIM4_M1_NoiseComparison_1437330256vs1438626136-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM4/SAGM1/Results/allDampRegressCompare_H1SUSIM4_M1_1437330256vs1438626136-1200.mat
Data:
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM4/SAGM1/Data/dampRegress_H1SUSIM4_M1_1437330256_1200.mat
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM4/SAGM1/Data/dampRegress_H1SUSIM4_M1_1438626136_1200.mat
r12560

MC1(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/MC1/Results/allDampRegressCompare_H1SUSMC1_M1_NoiseComparison_1437192600vs1437240215-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/MC1/Results/allDampRegressCompare_H1SUSMC1_M1_1437192600vs1437240215-1200.mat
r12557

MC2(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/MC2/SAGM1/Results/allDampRegressCompare_H1SUSMC2_M1_NoiseComparison_1436631330vs1438441235-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/MC2/SAGM1/SAGM1/Results/allDampRegressCompare_H1SUSMC2_M1_1436631330vs1438441235-1200.mat
Data:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/MC2/SAGM1/Data/dampRegress_H1SUSMC2_M1_1438441235_1200.mat
r12554

MC3(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/MC3/Results/allDampRegressCompare_H1SUSMC3_M1_NoiseComparison_1437115850vs1437282002-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/MC3/Results/allDampRegressCompare_H1SUSMC3_M1_1437115850vs1437282002-1200.mat
r12558

PRM(original results)(added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/Results/allDampRegressCompare_H1SUSPRM_M1_NoiseComparison_1435154988vs1435435046-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/Results/allDampRegressCompare_H1SUSPRM_M1_1435154988vs1435435046-1200.mat
r12559

PR2(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PR2/Results/allDampRegressCompare_H1SUSPR2_M1_NoiseComparison_1435154988vs1436654703-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PR2/Results/allDampRegressCompare_H1SUSPR2_M1_1435154988vs1436654703-1200.mat
r12556

PR3(original results)
Results:
/ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/SAGM1/Results/allDampRegressCompare_H1SUSPR3_M1_NoiseCompare_H1SUSPR3_M1_NoiseComparison_1435348334vs1435435046-1200.pdf
r12533
/ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/SAGM1/Results/allDampRegressCompare_H1SUSPR3_M1_1435348334vs1435435046-1200.mat
r12565

BS(original results)(added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/BSFM/H1/BS/SAGM1/Results/allDampRegressCompare_H1SUSBS_M1_NoiseComparison_1435062667vs1435435038-1200.pdf
r12535
/ligo/svncommon/SusSVN/sus/trunk/BSFM/H1/BS/SAGM1/Results/allDampRegressCompare_H1SUSBS_M1_1435062667vs1435435038-1200.mat
r12567
Data (new before time):
/ligo/svncommon/SusSVN/sus/trunk/BSFM/H1/BS/SAGM1/Data/dampRegress_H1SUSBS_M1_1435062667_1200.mat
r12535

Output
SRM(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/SAGM1/Results/allDampRegressCompare_H1SUSSRM_M1_NoiseComparison_1435154988vs1435435046-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/SAGM1/Results/allDampRegressCompare_H1SUSSRM_M1_1435154988vs1435435046-1200.mat
r12568

SR2(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SR2/SAGM1/Results/allDampRegressCompare_H1SUSSR2_M1_NoiseComparison_1435482383vs1436080373-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SR2/SAGM1/Results/allDampRegressCompare_H1SUSSR2_M1_1435482383vs1436080373-1200.mat
r12569

SR3(original results)
Results:
/ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/SAGM1/Results/allDampRegressCompare_H1SUSSR3_M1_NoiseComparison_1435348334vs1435435046-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/SAGM1/Results/allDampRegressCompare_H1SUSSR3_M1_1435348334vs1435435046-1200.mat
r12570

OMC
Results:
/ligo/svncommon/SusSVN/sus/trunk/OMCS/H1/OMC/SAGM1/Results/allDampRegressCompare_H1SUSOMC_M1_NoiseComparison_1437330259vs1438454240-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/OMCS/H1/OMC/SAGM1/Results/allDampRegressCompare_H1SUSOMC_M1_1437330259vs1438454240-1200.mat
Data:
/ligo/svncommon/SusSVN/sus/trunk/OMCS/H1/OMC/SAGM1/Data/dampRegress_H1SUSOMC_M1_1438454240_1200.mat
/ligo/svncommon/SusSVN/sus/trunk/OMCS/H1/OMC/SAGM1/Data/dampRegress_H1SUSOMC_M1_1437330259_1200.mat
r12582

SQZ
FC1
Results:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC1/SAGM1/Results/allDampRegressCompare_H1SUSFC1_M1_NoiseComparison_1437766177vs1438449277-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC1/SAGM1/Results/allDampRegressCompare_H1SUSFC1_M1_1437766177vs1438449277-1200.mat
Data:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC1/SAGM1/Data/dampRegress_H1SUSFC1_M1_1437766177_1200.mat
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC1/SAGM1/Data/dampRegress_H1SUSFC1_M1_1438449277_1200.mat
r12572

FC2
Results:

/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC2/SAGM1/Results/allDampRegressCompare_H1SUSFC2_M1_NoiseComparison_1437766177vs1438449277-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC2/SAGM1/Results/allDampRegressCompare_H1SUSFC2_M1_1437766177vs1438449277-1200.mat
Data:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC2/SAGM1/Data/dampRegress_H1SUSFC2_M1_1437766177_1200.mat
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC2/SAGM1/Data/dampRegress_H1SUSFC2_M1_1438449277_1200.mat
r12573

ITMs
ITMX M0(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGM0/Results/allDampRegressCompare_H1SUSITMX_M0_NoiseComparison_1435482383vs1436080373-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGM0/Results/allDampRegressCompare_H1SUSITMX_M0_1435482383vs1436080373-1200.mat
r12574

ITMX R0(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGR0/Results/allDampRegressCompare_H1SUSITMX_R0_NoiseComparison_1435482383vs1436080373-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGR0/Results/allDampRegressCompare_H1SUSITMX_R0_1435482383vs1436080373-1200.mat
r12575

ITMY M0(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMY/SAGM0/Results/allDampRegressCompare_H1SUSITMY_M0_NoiseComparison_1435482383vs1436080373-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMY/SAGM0/Results/allDampRegressCompare_H1SUSITMY_M0_1435482383vs1436080373-1200.mat
r12576

ITMY R0(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMY/SAGR0/Results/allDampRegressCompare_H1SUSITMY_R0_NoiseComparison_1435482383vs1436080373-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMY/SAGR0/Results/allDampRegressCompare_H1SUSITMY_R0_1435482383vs1436080373-1200.mat
r12577

ETMs
ETMX M0
(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGM0/Results/allDampRegressCompare_H1SUSETMX_M0_NoiseComparison_1435060998vs1436769334-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGM0/Results/allDampRegressCompare_H1SUSETMX_M0_1435060998vs1436769334-1200.mat
r12578

ETMX R0(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGR0/Results/allDampRegressCompare_H1SUSETMX_R0_NoiseComparison_1435060998vs1436769334-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGR0/Results/allDampRegressCompare_H1SUSETMX_R0_1435060998vs1436769334-1200.mat
r12578

ETMX L1(original results)
Results:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGL1/Results/allDampRegressCompare_H1SUSETMX_L1_NoiseComparison_1435060998vs1436769334-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGL1/Results/allDampRegressCompare_H1SUSETMX_L1_1435060998vs1436769334-1200.mat
r12579

ETMY M0(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMY/SAGM0/Results/allDampRegressCompare_H1SUSETMY_M0_NoiseComparison_1436521059vs1438453617-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMY/SAGM0/Results/allDampRegressCompare_H1SUSETMY_M0_1436521059vs1438453617-1200.mat
r12580
Data (new after time):
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMY/SAGM0/Data/dampRegress_H1SUSETMY_M0_1438453617_1200.mat
r12548

ETMY R0(original results) (added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMY/SAGR0/Results/allDampRegressCompare_H1SUSETMY_R0_NoiseComparison_1436521059vs1438453617-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMY/SAGR0/Results/allDampRegressCompare_H1SUSETMY_R0_1436521059vs1438453617-1200.mat
r12580
Data (new before and after time):
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMY/SAGR0/Data/dampRegress_H1SUSETMY_R0_1436521059_1200.mat
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMY/SAGR0/Data/dampRegress_H1SUSETMY_R0_1438453617_1200.mat
r12550

TMSs
TMSX(original results)(added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/TMTS/H1/TMSX/SAGM1/Results/allDampRegressCompare_H1SUSTMSX_M1_NoiseComparison_1435150628vs1437199319-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/TMTS/H1/TMSX/SAGM1/Results/allDampRegressCompare_H1SUSTMSX_M1_1435150628vs1437199319-1200.mat
r12553

TMSY(original results)(added loop suppression)
Results:
/ligo/svncommon/SusSVN/sus/trunk/TMTS/H1/TMSY/SAGM1/Results/allDampRegressCompare_H1SUSTMSY_M1_NoiseComparison_1437213557vs1437257352-1200.pdf
/ligo/svncommon/SusSVN/sus/trunk/TMTS/H1/TMSY/SAGM1/Results/allDampRegressCompare_H1SUSTMSY_M1_1437213557vs1437257352-1200.mat
r12581

Non-image files attached to this report
Displaying report 1-1 of 1.