Reports until 17:10, Tuesday 26 August 2025
H1 SUS (SUS)
edgard.bonilla@LIGO.ORG - posted 17:10, Tuesday 26 August 2025 (86574)
Created new OSEM estimator fits for PR3 Pitch and Yaw

This logpost is a follow up to the executive summary on PR3 OSEM estimator Filter and Blend design [LHO: 86563]

Oli took the measurements needed to commission the PR3 OSEM estimator in P and Y [see LHO: 86459]. The P measurements were taken with all M1_DAMP gains at -1, except for M1_DAMP_P, which was set to -0.2. Similarly, Y, All M1_DAMP gains were -1, except for M1_DAMP_Y, which was set to -0.2.

Ivey and I used her vectfit3 scripts to fit the transfer functions. The fits were committed to the SUS SVN under revision 12616. They live in 'sus/trunk/HLTS/Common/FilterDesign/Estimator/'

We made a few minimal changes to the original output from vectfit to match our expectation of the plants:

The images of the resulting filters, together with the data that Oli took are summarized in the attached pdfs.

In order of appearance, the zpk of the fits are:

 

Suspoint Y to M1_DAMP_Y fit

    'zpk([-0.012+20.621i,0,0,-0.012-20.621i,-0.012+11.426i,-0.012-11.426i],[-0.218+6.292i,-0.218-6.292i,-0.382+14.697i,-0.382-14.697i,-0.226+21.579i,-0.226-21.579i],-0.001)'

M1 drive Y to M1_DAMP_Y fit

    'zpk([-0.024-8.341i,-0.024+8.341i,-0.011+19.405i,-0.011-19.405i],[-0.088+6.403i,-0.088-6.403i,-0.115+14.485i,-0.115-14.485i,-0.069+21.379i,-0.069-21.379i],13.34)'

 

Suspoint P to M1_DAMP_P fit

    'zpk([-2.428-2.295i,-2.428+2.295i,-0.795-9.324i,-0.795+9.324i,-0.011-22.26i,-0.011+22.26i,0.034-5.811i,0.034+5.811i,0.382-13.672i,0.382+13.672i,1.168-1.459i,1.168+1.459i],[-0.507-1.499i,-0.507+1.499i,-0.395-10.253i,-0.395+10.253i,-0.204-4.167i,-0.204+4.167i,-0.141-4.759i,-0.141+4.759i,-0.13-13.137i,-0.13+13.137i,-0.066-22.16i,-0.066+22.16i],-0.001)'

Suspoint L to M1_DAMP_P fit

    'zpk([-0.773-7.242i,-0.773+7.242i,-0.635-18.11i,-0.635+18.11i,0.301-20.227i,0.301+20.227i,1.062-6.916i,1.062+6.916i,-99.035,-0.197,0.331,45.41],[-1.293-19.638i,-1.293+19.638i,-0.33-10.141i,-0.33+10.141i,-0.289-13.191i,-0.289+13.191i,-0.162-4.1i,-0.162+4.1i,-0.122-4.732i,-0.122+4.732i,-0.087-22.103i,-0.087+22.103i],0)'

M1 drive P to M1_DAMP_P fit

    'zpk([-0.339-4.576i,-0.339+4.576i,-0.031-21.157i,-0.031+21.157i,-0.009-5.455i,-0.009+5.455i],[-0.298-13.183i,-0.298+13.183i,-0.205-4.126i,-0.205+4.126i,-0.138-4.803i,-0.138+4.803i,-0.092-22.128i,-0.092+22.128i],80.907)'

Images attached to this report
Non-image files attached to this report