HAM3 Ry CRS blend turned on overnight

As a test, HAM3 Ry loop was switched to SUPERSENS6 blend, which includes a newly designed 30mHz CRS blend. It has been running stably for the last 20 minutes.

start_gps = 1468138518

note - to avoid confusing results I also turned off the CPS-DIFF loop

UTC Jul 15, 2026 08:15:00 UTC
Non-image files attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 14:57, Saturday 25 July 2026 (91252)

The loops stayed stable overnight and have been running for ~12 hours.

The overnight data was analyzed (first pdf) and spectra of the GS13 and CRS Ry were compared with the data from last week wtih the CPS/GS13 400mHz blend on the Ry loop. The in-loop CRS shows a factor of 100 improvement in the 0.2-0.5Hz band between the two times (purple vs pink), and the GS13 is now self noise limited up to ~0.8Hz (compare dark blue vs light blue).

A comparison of the Ry dof between all HAMs is also attached in the second pdf as a reference.

A tilt noise estimate used to design the blends is shown in the third pdf. This estimate uses the 3 sensor noises (CPS, GS13 and the updated CRS noise model), as well as (estimated) tilt input, and the 3 way blend. The total platform tilt noise for the new blend is shown in the dark blue dash lines and compared with the in-loop CRS measured spectrum. The dash green line shows the estimate for the 400mHz previous blend, compared with out-of-loop CRS spectrum. 

Note the 1-20mHz noise in the measured spectra is from windowing leakage (2582) rather than real tilt. I kept using the same Hanning window to be consistent with the reference data saved in dtt from last week. Eventually we should remake those plots in matlab (or dtt) with bmh windowing. 

The blends were designed using Brian's script attached to T2200393 as a starter point. The CRS sensor response is inverted in the blend filter (the same way we do with the GS13). The installed blend filters (including sensor response, as opposed to the plot shown in the main alog above) are shown on the last pdf

Next, we will assess how this improvement can help reducing the blend frequency in the horizontal loop.

The dtt template, blend script and blend filters are saved under : 

/ligo/svncommon/SeiSVN/seismic/HAM-ISI/H1/HAM3/CRS/Templates/dtt/2026-07-25_CRS_Spectra.xml
/ligo/svncommon/SeiSVN/seismic/HAM-ISI/H1/HAM3/CRS/Scripts/make_crs_blends.m
/ligo/svncommon/SeiSVN/seismic/HAM-ISI/H1/HAM3/CRS/Filters/CRS_BLNDS_30mHZ.mat

Non-image files attached to this comment