Displaying reports 38021-38040 of 89089.Go to page Start 1898 1899 1900 1901 1902 1903 1904 1905 1906 End
Reports until 14:10, Tuesday 22 October 2019
H1 CDS
david.barker@LIGO.ORG - posted 14:10, Tuesday 22 October 2019 (52625)
h1susey IPMI remote management board reset to get it to work

During this morning's h1susex remote power cycle I discovered that h1susey's management port was not working. I did the following to diagnose and fix it:

  1. @EY, check mgt eth port on h1susey [OK, LINK LIGHT]
  2. @EY, check sw-ey-h1fe port 3 [OK, LINK LIGHT]
  3. root@h1susey, check IPMI ethernet settings [OK]
  4. admin@sw-ey-h1fe check port 3 settings [OK]
  5. root@h1susey, cold restart the management board controller [FIXED THE PROBLEM]

No idea why the mgt board gummed up like this, with link lights on the ethernet port but no service, but luckily a cold reset fixed it.

H1 AOS
georgia.mansell@LIGO.ORG - posted 13:29, Tuesday 22 October 2019 (52608)
ALS-EX beam profile and investigations

Keita, Georgia

Today we went to End X to take a look at the ALS beam on ISCT EX as a comparison with end-y where the mode matching from the green beam to the arm is bad. At end X the input and reflected beams are much less clean than end Y.

Holes from ALS L6 X diameter [um] Y diameter [um]
4 1038 1337
10 1645 2145
18 2299 3057
22 2650 3468
30 3412 4354
35 3923 4902

 

Images attached to this report
H1 SEI
chiara.difronzo@LIGO.ORG - posted 12:34, Tuesday 22 October 2019 (52623)
PRCL filter testing over lockloss

Jenne, Chiara.

Yesterday we started to test to see what would be the actuation on the ISI CPS diferential configuration for PRCL using the LSC signals: the aim was to look at the forseen actuation. We tried to look at the output from the filters in real time but it did not succed because we found out that we were using an "unknown" calibrated PRCL signal (from OAF model, unused anymore; the proper ones have to be taken from CAL_CS model); so we decided to test the filters receiving the CAL_CS LSC signal (first pic): these filters are two low pass filters shown in second pic.

In Matlab, we chose a time when a lockloss happened and the calibrated PRCL data have been taken from H1:CAL-CS_PRCL_DQ. To be sure that we were choosing a lockloss moment, we used data from H1:LSC-POPAIR_B_RF90_I_ERR_DQ: this is a signal from a photodiode showing the amount of light in the cavities. When a lockloss happens, the signal on the phododiode drops off.

Calibrated PRCL is given in um, so we made sure we were working in the same units of measure, chosen to be nm because this is the unit of seismic loops. We applied the filters to the calibrated PRCL time series and we got the results in third pic: during a lockloss, calibrated PRCL shows a high frequency pulse, which is successfully low passed when filters are applied. This shows that if we use this filters, the actuation to apply would be such that the ISI would move of what shown in FILTER PRCL trace.

However, during lockloss the actuation would be around 20um, which is not bad, but maybe more that we want. So, this value could be lowered by a trigger that detects a lockloss and ramps off the LSC drive to the ISI. The trigger has been installed and we are going to use it once we are ready to push on the ISI.

Images attached to this report
H1 TCS
daniel.brown@LIGO.ORG - posted 11:31, Tuesday 22 October 2019 (52621)
CO2X looking misaligned

TLDR: CO2X looks misaligned on the HWS and phase camera images. Whether we want to realign it is up for discussion as CO2X is kept on during lock. This was because it helped RF and carrier builds up at the time.

Over the weekend with DRMI we were doing some phase camera tests. We decided to have a look at what effect the CO2s would have on the sidebands and see if what the phase camera is outputting makes sense. We had the phase camera running to take pictures of all the sidebands every 20s. We then dropped the power of CO2Y to 0W left if for 20 mins, increased it to 2W, waited, then returned it to nominal. We repeated the same with CO2X. We had DRMI ASC runnning during this process.

Looking at the raw phase camera images isn't particularly enlightening, unless something is completely wrong. One aspect that needs to be worked on is how we process and display the phase camera data in a usable manner. As we have both the amplitude and phase of each sideband we figured the best idea to try first is do a higher-order Hermite gaussian decomposition and analyse the change in mode content of each field. Ideally we would do this decomposition in the PRC mode propagated to the phase cameras position, however we don't actually know what that is in practice. Instead we just have to pick some beam basis that is something not too dissimilar to the beams we are seeing. I did a rough least-square fit for a gaussian HG00 to the data and got beam parameter values of:

X: w0=0.001362, z=6.688
Y: w0=0.001478, z=8.384

so the beam basis we are using here is slightly astigmatic. This doesn't necessarily mean the PRC mode is astigmatic, just that the beam at the phase camera is. We then run a decomposition of the 9 and 45 fields, plotted is the 1st and 2nd order mode changes to start with. Shown is that the 2nd order mode content of the beam varies as we change the CO2 power, as we'd expect. CO2Y has an ideal response, all we see is 2nd order changes, pretty much equal in amount between X and Y, so CO2Y looks well aligned.

However, CO2X looks more problematic. It induced both a 1st and 2nd order mode content change. It moves the fields diagonally and also creates a more astigmatic field. An image of the difference in shown here at the peak of the CO2X effect. The shape change (at the phase camera position) is mostly in the radius of curvature of the field and the misalignment mostly translation.

Averaging the upper and lower sideband I compare the 9 and 45 mode changes in figure. We can resolve a different shape between the 9 and 45 sidebands. The sidebands experience a different misalignment when CO2X is changed, the X displacement (HG10) change is different between the two. We can also see the lensing experienced in X is also different between the sidebands.

For reference I looked back at the HWSX images during this change. Not much can be seen from the weekend images. Comparing the CO2X switch on a week or so ago (with ring heaters off), we get this image. Comparing this to the cooldown of the IFO at the start of the commissioning break, we can see they not well centered. Looking at a power up at the end of September a dead pixel is causing an issue, but we can kind of see a deformation centered around 500, 400. Either way these don't look well aligned.

Images attached to this report
Non-image files attached to this report
H1 TCS (TCS)
aidan.brooks@LIGO.ORG - posted 11:30, Tuesday 22 October 2019 (52622)
ETMY HWS saturated by ALS laser

The ETMY HWS is now saturated by the ALS laser leakage into the HWS path. It's been like this since the ALS laser was energized last Friday (see attached plot of mean value of the peak 100 pixels on the HWS). We might be able to notch out the 532nm ALS laser using a notch filter.

Images attached to this report
H1 PSL
jason.oberling@LIGO.ORG - posted 10:10, Tuesday 22 October 2019 (52620)
PSL Power Watchdogs Reset (FAMIS 10733)

I reset both PSL power watchdogs at 17:06 UTC (10:06 PDT).  This completes FAMIS 10733.

LHO VE
patrick.thomas@LIGO.ORG - posted 10:01, Tuesday 22 October 2019 (52619)
HAM6 HV reenabled
Filiberto has re-enabled the HAM6 HV. It may trip again, but there is currently no time for it to be diagnosed.
H1 AOS (CAL)
vladimir.bossilkov@LIGO.ORG - posted 09:50, Tuesday 22 October 2019 - last comment - 15:54, Tuesday 22 October 2019(52618)
20191022 Search for Temperature Dependance in Pcal Photodetectors
Vlad and Niko

We have tasked ourselves to some of the backup hardware to search for what causes apparent temperature dependence on the output of the photodetectors used in integrating spheres for the Gold and Working standards (GS and WSx, x is the site for which the instrument is for) for calibrating optical power in all of the GW detector sites.

We are trying to explain the temperature dependence seen in [Zero_light_voltage_change.png], and [Normal_operation_voltage_change.png], in both images the DC offset has been subtracted. Temperature dependence was observed with no laser input to the integrating sphere with the cap attached to the front, and also when in normal operation when the whole integrating sphere was heated to 35 deg. C and allowed to cool. The magnitude of Voltage change due to temperature when there is laser light also incident on the detector is about 100x more.

We have two available circuits for this initial test.
[Board1], with only the photodiode (PD), which requires an external transimpedance amplifier (set to 50 times the gain of the GS) to get a voltage output.
[Board2], with no PD, which requires an external current source (set to the typical current seen in Pcal measurements) to get a voltage output.

We first looked at the output of the PD alone:
[Exp1.png]: We heated up the whole box containing [Board1] to 35 deg.C, and looked at the response. This setup observed significantly better noise performance than the GS (roughly 10 times less noise, when the data was corrected to equivalent gains), which We observed some temperature dependence, and the solid line plotted is the predicted dark current from the PD as it is set up, while the box is cooling [caveat: function for solid line was estimated from documentation of a different but similar PD. The data sheets for our PD have no information at all about its performance in photovoltaic mode (zero bias voltage)]. The good fit makes us confident we know the source of this signal, and is much smaller than what was seen in the experiments done in the past [Zero_light_voltage_change.png].
[Exp2.png]: We heated up the lid in front of the PD to the box containing [Board1] to 35 deg.C  Vlad predicted the PDs should be sensitive to changes in the black body radiation of objects close the to PD - unfortunately no change in output was seen in this experiment. This rules out his theory, unless PD behaves differently somehow when illuminated with some optical power (some non linear output behavior). Looking at the data, one could argue that the PD warmed up some time after placing the lid in front of it, giving a slight change to the response, but this could easily be some ambient effect.

Next we look at the output given a constant current instead of a PD, to the circuit board, [Board2]:
[Exp3.png]: We heated up the whole box containing [Board2], and looked at the response. The data from [Board2] is in red, and the data from the GS is in blue, and DC offsets have been subtracted. Unfortunately our experiment is swamped with noise (roughly 10^6 times more peak rms noise than the GS), and the effect we are looking for is somewhere deep in that noise. Our box also cooled much faster than experiments done before since it was sitting on a table (completely cool in about 10 minutes). In the future we will lift it to make the cooling slower. The noise should not be due to the current source, going by it's specifications and our measurements of its output before the experiment. The board has a different Op.Amp., with a capacitor missing on its power supply, at the output point of the circuit, compared to the specification in D1300210. Talking with Niko, all the boards were put together by the same company and should be identical, unless this is some weird experiential board.

Future plan:
1)Resolve Noise issue of [Exp3]:
	a)Niko will chase up circuit boards assembly company to double check what is on the circuits and if some were different
	b)We can check frequency of noise in [Board2]- if high frequency could be due to the missing capacitor
	c)Maybe one board had faulty components and was set aside?
	d)Open a Working standard to check and compare is the last option
2)Repeat [Exp3] and see if we get the temperature dependence that we expect, with a noise level at least comparable to the GS
3)If we see the expected temperature dependence from [Normal_operation_voltage_change.png]: we can use preheated tools to apply pinpoint heat to individual components and find what is most susceptible to temperature dependence
4)If we do not see anything on [Board2], we go back to [Board1] and repeat [Exp1] and [Exp2] in the presence of optical light (ie mounted on an integrating sphere) to confirm the outcomes of [Exp1] and [Exp2] in the presence of an optical signal.
5)If we still see nothing - perhaps temperature dependence is not what we should be looking at. Ethan Payne (fellow who was looking at some of this data before me) makes a point that what we see could be a humidity dependance, though testing that is much more difficult.
Images attached to this report
Comments related to this report
vladimir.bossilkov@LIGO.ORG - 15:54, Tuesday 22 October 2019 (52627)
[Board2] got a new Op.Amp and capacitor after some excellent soldering by Niko. Noise is gone, and we'll continue what we were doing tomorrow.
LHO VE
kyle.ryan@LIGO.ORG - posted 08:50, Tuesday 22 October 2019 - last comment - 18:35, Tuesday 22 October 2019(52612)
Misc. LVEA vacuum

Energized HAM5/HAM6 AIPs, Valved-in IP14, Valved-in IP4, IP3, IP2 and  IP1.

Comments related to this report
kyle.ryan@LIGO.ORG - 09:06, Tuesday 22 October 2019 (52614)

Curriously, IP1 and IP2 indicate a 4-channel sum of ~1.6mA @ ~7000V while IP3 and IP4 indicate a 4-channel sum ~4mA @ ~7000V (15 minutes after changing valve status') and their respective controllers. 

chandra.romel@LIGO.ORG - 09:27, Tuesday 22 October 2019 (52617)

Any correlation with chevron baffles? I can't remember which IPs have them and which don't.

kyle.ryan@LIGO.ORG - 12:26, Tuesday 22 October 2019 (52624)

1105 hrs. local -> Valved-out Vertex Turbo

kyle.ryan@LIGO.ORG - 18:26, Tuesday 22 October 2019 (52630)

I ran a few hours today with only IP14 pumping on HAM6 to see if shutting down the turbo+backing cart would be an option (Daniel S. keen on elilminating noise).  The pressure looked like it might "turn the corner" at 5 or 6 x 10-6 torr but I aborted the exercise in observance of our default policy of not sacrificing equipment life expectancy.  HAM6 back on turbo only until further notice.

kyle.ryan@LIGO.ORG - 18:35, Tuesday 22 October 2019 (52631)

Sorry C for the late response - I think that IP1 and./or IP2 have UV baffles while IP3 and IP4 do not. 

Update - I noted that this disparity remained even after valving-out the Vertex turbo later on. 

H1 CDS
david.barker@LIGO.ORG - posted 08:47, Tuesday 22 October 2019 - last comment - 09:18, Tuesday 22 October 2019(52611)
h1susex models crashed this morning

At 06:45 PDT the models on h1susex crashed with a timing error. The IO Chassis can still be seen by the front end, I'm restarting the models.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 08:55, Tuesday 22 October 2019 (52613)

IOP model is not starting. dmesg output is shown in attached text file.

Non-image files attached to this comment
david.barker@LIGO.ORG - 09:11, Tuesday 22 October 2019 (52615)

I have power cycled h1susex:

  • took it out of dolphin fabric
  • issued the powerdown command
  • used IPMI to power the computer back up

The IOP model is now running, but with a slight negative IRIGB excursion. I'm waiting for this to clear, while this is in effect IPC and DAQ data have timing errors.

david.barker@LIGO.ORG - 09:18, Tuesday 22 October 2019 (52616)

Timing is good, handing over to Patrick to complete the recovery.

H1 CDS
david.barker@LIGO.ORG - posted 21:29, Monday 21 October 2019 (52610)
Squeezer Beckhoff SDF restarted in order to resync it to the latest monitor file

Daniel, Dave:

Daniel noticed that the Beckhoff SDF system for C1-PLC4 had not been restarted since some recent system changes. I found that the SDF files had been changed in early Oct, but the SDF process has been running since June. I restarted h1sysecatc1plc4sdf at 21:24 PDT.

LHO VE
kyle.ryan@LIGO.ORG - posted 19:34, Monday 21 October 2019 - last comment - 20:40, Monday 21 October 2019(52606)
HAM6 indicated pressure fuctuating wildly

I've noticed over the past hour or so that HAM6's pressure is fluctuating by, at least a factor of 4 -> I spoke with Georgia on the phone and she trended HAM6 pressure and confirmed -> I am heading out to the site to investigate.

Comments related to this report
georgia.mansell@LIGO.ORG - 19:39, Monday 21 October 2019 (52607)

Attaching a trend of PT-110, the gauge at HAM6. At 01:39 UTC the pressure reading started fluctating wildly.

At 01:50 UTC the fast shutter closed, so presumably the high voltage got tripped off in HAM6.

At 02:28 UTC we got a verbal alarm in the control room that the vacuum pressure was high at HAM 6.

Images attached to this comment
kyle.ryan@LIGO.ORG - 20:40, Monday 21 October 2019 (52609)

I checked out the turbo and backing cart at HAM6 and the turbo RPM and temperature, as well as, the foreline pressure are as expected and are stable.  As can be seen in the attached graph of PT110 (second data) the indicated pressure spikes are not followed by "real" pump down curve profiles.  Thus, this recent erratic behavior is not due to real pressure flucuations but, rather, is the result of the transducer or the data processing.  I'll leave it to others to consider the pros and cons of changing or bypassing the HV interlock should these indicated pressure fluctuations result in nuisance interlock trips. 

 

Non-image files attached to this comment
Displaying reports 38021-38040 of 89089.Go to page Start 1898 1899 1900 1901 1902 1903 1904 1905 1906 End