ryan.short@LIGO.ORG - posted 11:12, Tuesday 26 August 2025 (86570)
PSL 10-Day Trends

FAMIS 31100

ISS diffracted power has generally been trending down over the past week, but at least it's starting to settle back at the desired setpoint of 4%. No other major events of note.

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:41, Tuesday 26 August 2025 (86569)
Tue CP1 Fill

Tue Aug 26 10:07:19 2025 INFO: Fill completed in 7min 15secs

 

Images attached to this report
H1 ISC
daniel.sigg@LIGO.ORG - posted 10:38, Tuesday 26 August 2025 - last comment - 13:21, Tuesday 26 August 2025(86568)
Whitening chassis for ASC-AS_C and OMC-REFL_A changed

This continues work from alog 86442. A new cable, D2500252, was made to replace the old ISC_455 (D2200327) and ISC_39 (standard 25-pin d-sub cable).

The DC offset have been adjusted but not accepte din SDF.

The second anti-whitening filter of OMC-REFL_A is now a normal anti-whitening filter, zpk([10],[1],1,"n"), and not the antiLP, zpk([49.63],[497.5],-0.9995,"n"). However, the filter files are not updated yet.

Comments related to this report
elenna.capote@LIGO.ORG - 12:53, Tuesday 26 August 2025 (86579)

Initial alignment post-maintenance is currently failing at SR2_align because there is no signal on AS_C. We think this change may be the culprit.

daniel.sigg@LIGO.ORG - 13:21, Tuesday 26 August 2025 (86582)

And back to the old board. Seems we have an issue with the new cable...

H1 SUS (SEI)
jeffrey.kissel@LIGO.ORG - posted 10:03, Tuesday 26 August 2025 (86567)
H1 SUS SR3 M1 Pitch and Yaw Estimator: Was missing L to P Sus. Point Input -- now Installed
J. Kissel, E. Bonilla, I. Zhong, B. Lantz, O. Patane

Per LHO:86563, Edgard found/noticed that the H1SUSSR3 M1 Pitch Estimator system wasn't using the Sus Point L to M1 P contribution that had been a part of the design intent. I used 
    /ligo/svncommon/SusSVN/sus/trunk/HLTS/Common/FilterDesign/Estimator/
        make_SR3_pitch_model.m      rev 12618
to install the extra filters into FM1 and FM2 of the H1:SUS-SR3_M1_EST_P_FUSION_MODL_SUSP_L_2GAP filter bank.
The script uses 
    /ligo/svncommon/SusSVN/sus/trunk/HLTS/Common/FilterDesign/Estimator/
        Clean_fits_H1SR3_P_2025-08-05.mat      rev 12594

Steps to install:
(0) From the sitemap, open up the SR3 overview screen, and find the pitch estimator overview screen as well as the Sus Point to M1 filter bank collection.
(1) Open matlab, navigate to the above directory and open the script.
(2) TURN THE ESTIMATOR OFF, by using the the fader switch: H1:SUS-SR3_M1_EST_P_SWITCH_NEXT_CHAN goes from 3.0 to 2.0 (but you can do this with the "Use OSEM" button on the estimator overview screen)
(3) Run the matlab script -- this uses autoquack (LIGO's home brewed matlab-to-foton filter install function) to push the matlab filter to SR3's foton file.
(4) Open up the SR3 GDS_TP screen, where there should now be a "Modified Filter File" message shown on the channel H1:FEC-44_MSG2. Use the !DIFF button -- which pops up a screen showing the diff between what's installed and what you're about to install -- to validate at least that "the only filter bank that's been touched or modified is the new L to P filter" (since it's tough to validate Second Order Sections by eye).
(5) THE ESTIMATOR IS OFF, RIGHT? OK, then hit the "COEFF LOAD" button. The filter names listed below should appear in FM1 and FM2 of the EST_P_FUSION_MODL_SUSP_L_2GAP bank.
(6) THE ESTIMATOR IS OFF, RIGHT? OK, then use the MEDM interface on the EST_P_FUSION_MODL_SUSP_L_2GAP screen to turn on the input, output, FM1 and FM2, and set the gain to 1.0
(7) While the impulse response of the filter settles, set the H1:SUS-SR3_M1_EST_P_FUSION_MODL_SUSP_L_2GAP_STATE_GOOD filter module state checker bit word to match the current state's word H1:SUS-SR3_M1_EST_P_FUSION_MODL_SUSP_L_2GAP_STATE_NOW. Should need a change from 0x2000000 to 0x6000f4.
(8) Turn the estimator back ON. And at least look at the estimator overview screen to confirm that sensor signals are not going bonkers. In fact, they really shouldn't look that different at all.
(9) If you like what you see, go back to the GDS_TP screen and accept the new EPICs settings with this new filter ON in both the safe and observe snap files:
    /opt/rtcds/userapps/release/sus/h1/burtfiles/
        h1sussr3_safe.snap
        h1sussr3_observe.snap
commit these to the userapps svn with the appropriate message when you're done.
(10) Commit the updated foton file to the userapps svn with a similar message
    /opt/rtcds/userapps/release/sus/h1/filterfiles/
        H1SUSSR3.txt
(11) Profit! Start looking at the performance!

Here's the design explicitly:
SR3_M1_EST_P_FUSION_MODL_SUSP_L_2GAP
FM1        "ISI_fit_L"      Fit to (M1 Response / Sus. Point L Excitation) TF, plus calibration from nm to um.
    sos(0.0001142264006754552, 
        [-2.0000000000000009; 1.0000000000000011; 
         -1.999975478282779; 0.99997585128576594; 
         -1.999816005993748; 0.99982977526725314; 
         -1.999982188592295; 0.99998283118601283; 
         -1.999884963247067; 0.9998851520162283; 
         -1.999988292191436; 0.99998835461999513; 
         -2.0001080651245839; 1.0001082464362681; 
         -1.999989760987597; 0.99998984142840619; 
         -2.000082349605993; 1.0000836590827351; 
         -1.9999909890250209; 0.99999272379034698])
FM1        "to_um/nm"       Vestigial Organ; calibration is folded in to FM1's filter these days.
     zpk([],[],1.000000000000000,"n")
Images attached to this report
H1 TCS
matthewrichard.todd@LIGO.ORG - posted 09:27, Tuesday 26 August 2025 - last comment - 14:20, Tuesday 26 August 2025(86566)
Changing TCS-SIM values for surface defocus effects

M. Todd, C. Compton, S. Dwyer


We changed the gain settings in TCS-SIM that convert the powers of each actuator (including self-heating) to surface defocus for calculating the overall radius of curvature of each test mass at a given thermal state.

The motivation for this was that the simulation seems to be largely overestimating the Higher Order Mode spacing. Hopefully, with these new predictions, we will observe better agreement between the simulation and HOM measurements.

We also changed the absorption values using values taken from alog 80714 for the ITMs, and using galaxy for the values for the ETMs.

 

Images attached to this report
Comments related to this report
anthony.sanchez@LIGO.ORG - 14:20, Tuesday 26 August 2025 (86585)

Hey.... these are some SDF's that I think are related to your work.
I accepted them all.

Images attached to this comment
H1 General
anthony.sanchez@LIGO.ORG - posted 07:43, Tuesday 26 August 2025 - last comment - 13:12, Tuesday 26 August 2025(86565)
Tuesday Ops Maintenance Day

TITLE: 08/26 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 15mph Gusts, 9mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.09 μm/s
QUICK SUMMARY:
H1 has been locked for 10+ hours.

Today At 14:21 UTC it appears the Magnetic Injections started.
At 14:40 UTC Back to Observing.
Down to Commissioning again at 14:45 UTC



Expected Tuesday Maintenance Work:
VAC - MX and MY pump install work continuing (booster pumps will be connected)
VAC - BSC1 AIP troubleshooting. Needs LASER SAFE condition.  Postponed
VAC - LN2 delivery: MX (CP5) and MY (CP3)
VAC - FC guage work (pumping)
Randy - North Bay - cleaning of top of eMod
Randy - East Bay - remove C3 cleanroom sock cover over HAM5 & 6
FAC - rock delivery at Staging building
CDS -Daniel - Change the whitening chassis that is currently used for the ASC-AS_C QPD
Fil - HAM5&6 racks - install of BHD stuff
LN2 - MY & MX
Charge meas't ?

 

 

Comments related to this report
anthony.sanchez@LIGO.ORG - 12:29, Tuesday 26 August 2025 (86576)

SNEWS Test @ 16:59 UTC 
Vaccum Mid X Pressure alarm Low 17:53 UTC.
12 Hours ago there was an increase in CER Temps

Expected Tuesday Maintenance Work:
Done - VAC - MX and MY pump install work continuing (booster pumps will be connected)
Postponed ------ VAC - BSC1 AIP troubleshooting. Needs LASER SAFE condition. 
Done - VAC - LN2 delivery: MX (CP5) and MY (CP3)
"Done ....For Now...." ~ Gerardo - VAC - FC guage work (pumping)
Done North Bay - cleaning of top of eMod
Done  East Bay - remove C3 cleanroom sock cover over HAM5 & 6
Done -  FAC - rock delivery at Staging building 
Done - CDS -Daniel - Change the whitening chassis that is currently used for the ASC-AS_C QPD
Done - Fil - HAM5&6 racks - install of BHD stuff
Done - LN2 - MY & MX
Done - SUS Charge meas't ?
Done - Beaver Bark gravel dumps 
Done - Dust Mon Pump Swap
 

CER temps are now dropping

camilla.compton@LIGO.ORG - 13:12, Tuesday 26 August 2025 (86577)OpsInfo, SQZ

Elenna noticed that we dropped from Observing 8 times last night, for around 2 minutes each time, plot. This was mainly due to the OPO loosing lock, reporting "2025-08-26_08:04:01.503798Z SQZ_OPO_LR [LOCKED_CLF_DUAL.run] USERMSG 0: OPO not really locked or maybe locked in a wrong mode" and taking itself to DOWN. I don't see a clear reason why, plot attached.

The OPO PZT was around 100V but we can operate up to 110V and the OPO ISS AOM was at it's central value of 5V. 

There is some OPO TRANS glitches where the power drops by more than 20% but the OPO stays locked, plot attached.

  • 7:10UTC OPO lost lock
  • 7:14UTC OPO lost lock
  • 7:18UTC FC lost lock
  • 8:03UTC OPO lost lock
  • 9:05UTC FC lost lock
  • 10:06UTC ISS LL counter.
    • Message "2025-08-26_10:06:12.261378Z SQZ_OPO_LR [LOCKED_CLF_DUAL.run] USERMSG 0: Disabling pump iss after 10 lockloss counter. Going to through LOCKED_CLF_DUAL_NO_ISS to turn on again."
    • The OPO ISS turned off, we see no reason why, it was at 5V, the middle of it's range, see attached plot.
  • 10:07UTC OPO lost lock
  • 10:15UTC OPO lost lock

Tagging OpsInfo, please check for drops in Observing overnight using the verbal alarms computer and tag the relevant team in your alog it it's obvious what caused the observing drop. For SQZ, there is a ndscope under sitemap > SQZ > SQZ Overview > ! SQZ Scopes > SQZ Guardians that compares the H1:GRD-IFO_OK channels to all SQZ Guardian to see if they were the reason for the observing drop.

Images attached to this comment
H1 CDS
erik.vonreis@LIGO.ORG - posted 06:32, Tuesday 26 August 2025 (86564)
Workstations updated

Workstations updated and rebooted.  This was an OS packages update.  Conda packages were not updated.

H1 SUS
edgard.bonilla@LIGO.ORG - posted 23:17, Monday 25 August 2025 (86563)
Committed Fits and Bandpasses for the PR3 OSEM estimator

Edgard, Ivey, Brian. [This a summary logpost. More detailed information on the fits and blends is now available, together with better plots]

post on PR3 OSEM estimator fits: [LHO: 86574].
post on PR3 OSEM estimator blends:[LHO: 86588].


We committed the fits, blend designs, and scripts needed to commission the H1 PR3 OSEM estimator. to the 'sus/trunk/HLTS/Common/FilterDesign/Estimator' folder.
Hopefully this will be sufficient for some commissioning soon

The files committed are:

on revision 12616:
fits_H1PR3_P-2025-08-19.mat    [fits for H1PR3 with pitch damping gain set to -0.2]
fits_H1PR3_Y_2025-08-19.mat    [fits for H1PR3 with yaw damping gain set to -0.2]
make_PR3_pitch_model.m          [script to load the fitted PR3 pitch transfer functions into the foton file. It should modify 3 filter banks]
make_PR3_yaw_model.m            [script to load the fitted PR3 yaw transfer functions into the foton file. It should modify 2 filter banks]

make_SR3_pitch_model.m          [script to load the fitted PR3 pitch transfer functions into the foton file. It should modify 3 filter banks | there was a typo in this script]

on revision 12617:
blend_PR3_pitchv2.m                                                                  [creates tuned bandpasses for the PR3 P estimator]
Estimator_blend_skinnynotch_PR3yaw_20250825.m            [creates tuned bandpasses for the PR3 Y estimator]
make_PR3_blends.m                                                                   [loads the PR3 Pitch and Yaw bandpasses. It should modify 4 filter banks]


The fits are shown in the pdf attached. We will post a detail of the blends, as well as the zpk designs tomorrow.

 

Non-image files attached to this report
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 22:00, Monday 25 August 2025 (86561)
OPS Eve Shift Summary

TITLE: 08/26 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 158Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY:

IFO is in NLN and OBSERVING as of 04:05 UTC.

Very quiet shift in which we had one ETMX Caused Lockloss (alog 86559). Lock reacquisition was fully automatic but did require an initial alignment following DRMI lock issues and one DRMI LL.

 

 

H1 General (Lockloss)
ibrahim.abouelfettouh@LIGO.ORG - posted 19:53, Monday 25 August 2025 - last comment - 21:48, Monday 25 August 2025(86559)
Lockloss 02:29 UTC

Lockloss due to ETM Glitch.

Comments related to this report
ibrahim.abouelfettouh@LIGO.ORG - 21:48, Monday 25 August 2025 (86560)

Back to NLN at 04:05 UTC

H1 General
oli.patane@LIGO.ORG - posted 17:10, Monday 25 August 2025 - last comment - 17:10, Monday 25 August 2025(86557)
Ops Day Shift End

TITLE: 08/25 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 154Mpc
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: Observing and have been Locked for over 14 hours now. This has been a very quiet shift. We had some commissioning earlier, and then had an earthquake coming in that was in the middle of the green earthquake zone so we decided to use the Hi ASC Gain button (first tested 86364). It turned out that the earthquake was so small that we didn't even need to go into Earthquake mode, but it was a good second test of this mode, and I found an import error in the script that was easy to fix but might  have been bad if it had been found by someone facing an actual lockloss-causing earthquake.
LOG:

14:30 UTC Observing and have been Locked for over 4.5 hours
15:30 Out of Observing for Commissioning
18:36 Back into Observing
19:34 Hanford site monthly emergency testing phone call
22:42 Out of Observing due to earthquake coming in - we decided to test out the Hi ASC Gains script
22:53 Reverted back to NLN with the ASC Low Noise script
22:54 Back into Observing 

Comments related to this report
ibrahim.abouelfettouh@LIGO.ORG - 17:10, Monday 25 August 2025 (86558)
Start Time System Name Location Lazer_Haz Task Time End
15:01 FAC Nelly MY n Tech clean 15:44
15:04 FAC Kim MX n Tech clean 16:10
16:44 FAC Eric EX n Checking out part that needs to be replaced 17:03
20:39   Camilla OpticsLab n Sorting parts 21:17
H1 SUS (ISC, SEI)
oli.patane@LIGO.ORG - posted 16:55, Monday 25 August 2025 - last comment - 14:22, Tuesday 26 August 2025(86551)
Correction/Update: SR3 Estimator Impact on ASC (plus new OMC and ASC-AS plots)

Jeff, Oli

On Thursday (86507) I alogged the differences we were seeing in the ASC with the SR3 estimator on. The time that I was taking as our 'reference time' for the estimator off, however, doesn't seem like it was a good time showing the lowest the ASC noise could be. You could say this caused us to over estimat(or) the differences.
So I plotted some more times with the estimator off, then with the estimator on, and I found that maybe the SR3 noise is limiting the ASC noise less than shown in 86507. However, I also found that below 0.2 Hz, where we thought that the estimators were elevating the noise, that also seems to have been not related to the estimator, so that is something we might not have to worry about. 
Of course the peaks at 0.6 and 0.7 Hz are elevated in the estimator plots below due to not damping them in the inital blend filter (mentioned in 86507), and this is something that we partially fixed this morning (86544), and will be working on further damping at the next available commissioning time.

There are still times where the estimator on makes the noise better at some frequencies, but there are also other times where the estimator is on, but something else is limiting the noise, so it looks like SR3 isn't limiting the noise very much at all. It will still be interesting to see if adding estimators onto the rest of the SRC give us different results.

In the plots below, I am showing the variation in noise with the estimators off and the estimators on,
The 'bad' time for the estimators OFF is: 2025-08-17 09:00 UTC (green)
The 'good' time for the estimators OFF is: 2025-08-20 18:29 UTC (blue)
For the estimators ON times, they're both 'good' and 'bad' at different frequencies, so I'll just list their times:
2025-08-21 16:35 UTC (red)
2025-08-24 18:18 UTC (gold)

  Pitch Yaw
ASC-DHARD Error
Est OFF Est ON Both Est OFF Est ON Both
Control
Est OFF Est ON Both Est OFF Est ON Both
ASC-MICH Error
Est OFF Est ON Both Est OFF Est ON Both
Control
Est OFF Est ON Both Est OFF Est ON Both
ASC-SRC1 Error
Est OFF Est ON Both Est OFF Est ON Both
Control
Est OFF Est ON Both Est OFF Est ON Both
ASC-SRC2 Error
Est OFF Est ON Both Est OFF Est ON Both
Control
Est OFF Est ON Both Est OFF Est ON Both
ASC-AS_A_DC Control
Est OFF Est ON Both Est OFF Est ON Both
ASC-AS_B_DC Control
Est OFF Est ON Both Est OFF Est ON Both
ASC-OMC_A Control
Est OFF Est ON Both Est OFF Est ON Both
ASC-OMC_B Control
Est OFF Est ON Both Est OFF Est ON Both
OMC-DCPD_SUM_OUT Est Off Est ON Both
OMC-REFL_A_LF_OUT Est Off Est ON Both

 

Images attached to this report
Comments related to this report
edgard.bonilla@LIGO.ORG - 22:02, Monday 25 August 2025 (86562)

Jeff, Oli, this is good to know!

I also noticed that the SUSpoint L to M1 P block of the estimator does not have the corresponding filter fit. For the Pitch degree of freedom, we expect the ISI longitudinal contribution to be relevant enough that it should be modeled. Maybe this explains some of the inconsistent behavior around the length/pitch modes.

I modified 'make_SR3_pitch_model.m' inside sus/trunk/HLTS/Common/FilterDesign/Estimator to ensure that we get the correct fits into this filter bank. This update is current as of SVN revision 12616

In total, autoquack should populate 3 filter banks for the pitch estimator:

SR3_M1_EST_Y_FUSION_MODL_SUSP_L_2GAP
SR3_M1_EST_Y_FUSION_MODL_SUSP_P_2GAP
SR3_M1_EST_Y_FUSION_MODL_DRV_P_2GAP
brian.lantz@LIGO.ORG - 14:22, Tuesday 26 August 2025 (86586)

Wow. Thanks for all the data. One quick clarification. Above it says "Of course the peaks at 0.6 and 0.7 Hz are elevated in the estimator plots below due to not damping them in the inital blend filter" 

To be clear, the first version of the pitch estimator was designed to damp these peaks. But - recall that "estimator" is the blend of the model and the measurements. In the first version, nearly all of the damping signal in the estimator was from the MODEL, whereas the 2 higher frequency peaks (and all 3 yaw peaks) use the MEASUREMENT path from estimator. In version 1, the model path for the estimator wasn't working well. This seems to mean that the model is not correctly predicting the gap motion. We suspect that this is because of an unmodeled drive, which we think is DAC noise.

So we were applying damping with the estimator, but it was not working as expected. Version 2 has updated blend filters which use the osem signals around all 4 peak frequencies, and hopefully this will improve the estimator performance.

H1 ISC
sheila.dwyer@LIGO.ORG - posted 16:32, Monday 25 August 2025 - last comment - 15:34, Thursday 20 November 2025(86555)
new version of noise budget code: WIP

I've made a fresh start on the noise budget code, using much of the work and many of the functions from aligoNB, but in a code that should be overall simpler for us to work with.  This exists in a repo here: simplenb.

Noises estimated using the excess power method can be read in either using gps times or from a dtt template. .xml files are tracked using git lfs and read in by dttxml. If a list of gps times is provided then the code will download the data using gwpy and save asds as a .pkl file, so that the data doesn't need to be downloaded each time the budget is run. Deleteing the pkl file from the local copy will cause it to redownload the data if the user wants to change times or resolution.  The excess power projection is done using the frequency resolution of the dtt file, or right now it is hard coded to an fft length of 3 seconds for those made using a list of gps times.  The noises are rebinned to a frequency vector specified for the budget after the projections are made. 

Thermal noises are imported from gwinc.  Quantum noises are also calculated using gwinc, which is why this code needs to be run in an environment that uses Kevin's superQK branch of gwinc.  I've added a function save_quantum_params to my quantum noise modeling repo that takes a template of a yaml file including all the parameters you think are important for modeling quantum noise, and a ifo struct, which saves a yaml file with the current parameters.  This function is also available in the quantum_utils.py function in this repo, so that people can use it with any method they like of generating a gwinc model of quantum noise to incorporate into this noise budget. I think it is best to leave the quantum noise budgeting separate from this repo for now, because the code for that is still evolving.  For now I've used the quantum parameters where all the missing squeezing is explained by frequency dependent loss from 85942, the next step is to add mode mismatches to that model.

Running the budget.py script will generate noise budget plots, you can choose how many layers deep to go in plotting sub-budgets by setting that parameter in the make_all_plots function call in the final lines.  The plots attached were made using the injections that Camilla made this morning (86550), and a reference time of 20:00 UTC.

Still to do:

Non-image files attached to this report
Comments related to this report
alexandra.mitchell@LIGO.ORG - 15:34, Thursday 20 November 2025 (88189)
We used the simplenb code to make a plot for the the Stanford seismic NSF proposal, I've attached it below for reference. 

Some things which we found along the way getting this to run properly as someone offsite who doesn't have a lot of experience with cds
* We struggled with LFS and eventually manually downloaded the files needed, we couldn't get them to download via git for some reason 
* superQK environment is a branch of pygwinc https://git.ligo.org/gwinc/pygwinc 
* The aligoNB repo is also needed 
* If working offsite some lines in excess_power_utils under def import_dtt_calib should be edited to the correct directory

Hope this is useful for anyone trying to do the same offsite! 

Non-image files attached to this comment
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:14, Monday 25 August 2025 (86556)
OPS Eve Shift Start

TITLE: 08/25 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 13mph Gusts, 10mph 3min avg
    Primary useism: 0.11 μm/s
    Secondary useism: 0.09 μm/s
QUICK SUMMARY:

IFO is in NLN and OBSERVING as of 17:20 UTC (13.5 hrs!) (with some drops out of observing for various reasons).

Oli just finished testing Jim and Elenna's Earthquake robust ASC state during an earthquake, though we probably would have survived since it was a small EQ. I will turn this back on to continue testing if a sufficiently large EQ rolls in.

Otherwise, IFO is behaving excellently.

H1 SUS (SEI)
jeffrey.kissel@LIGO.ORG - posted 15:43, Monday 25 August 2025 (86553)
H1 SUS SR3 M1 Pitch and Yaw Estimator: Local Performance Metrics After Changing Pitch Blend Filter to -v2
J. Kissel, O. Patane, B. Lantz

Continuing to refine my understanding of the metrics for the GS13 FF Estimator, I update the plots from LHO:86503. Also, I barely explained the plots there, so I'll try to do a better job here.

First Point: Concepts and Clarification
I've had a conceptual misunderstanding about what the estimator is at its core. Discussions with Brian have cleared this key point up for me: I had been calling the estimator a "GS13 Feed Forward Estimator," but that neglects a key innovation of the estimator. Not only does it use the HAM5 ISI GS13's to predict the susp-point motion input -- that's the feed-forward part -- but it also takes the total top mass *requested* drive from the suspension's M1 stage as well, and (with a 1 clock cycle delay) feeds that back as another input to the estimator. That's the composition of the estimator super sensor: the sum of the estimated input motion from the ISI as well as the total requested drive "including the estimator controls, what's left of the classic, broadband OSEM control, and any ISC drive". In the case of SR3, there is no AC ISC drive, just alignment offsets, so for the purposes of us looking at the ASDs as performance metrics it's irrelevant. So, saying that description of the total requested drive sentence again for SR3: "including the estimator controls [from GS13s and filtered estimated total drive] and what's left of the broadband OSEM control."

Remember, for SR3, the original total EPICs gain on the OSEM-only damping loops was -0.5. So, "what's left of the OSEM-only damping loops" is -0.1 of the OSEM-only damping loops and whatever percentage of OSEMs is allowed to pass through the OSEM / Estimator Super-sensor blend on resonance.

So -- what *are* the relevant local metrics?
On the sensor side -- it's interesting (and necessary) to compare 
    (a) the OSEM signal 
    (b) the total Estimator Super Sensor, which is comprised of
    (c) the Estimated M1 motion caused by Suspension Point Motion, predicted by the HAM5 GS13s
    (d) the Estimated M1 motion caused by M1 drive, predicted by the internally *requested* M1 drive

On the output drive side -- it's interesting (and necessary) to compare
    - the total internally requested drive; in the case of SR3 only from 
       (1) the small, but broadband fraction of control from the OSEMs
       (2) when OFF, the larger broadband fraction of control from the OSEMs
       (3) when ON, the estimator control from 
           . estimated M1 motion via GS13, 
           . M1 drive, and 
           . larger fraction of blend-filtered OSEM control
       
The first two "TRACEKEY" attachments show these 4-trace "sensor" and 3-trace "drive" plots for pitch, with the estimator overview screen handy so you can relate the traces with where they are in the control system topology.

Second Point: Pitch Sensors
Alright, so let's look at the pitch plots. Open the "Pitch Sensor Metrics when P and Y Estimators are both ON" alone plot first.
    (i) As we already knew, the raw OSEM signal can't see anything. It's dominated by its sensor noise for the vast majority of the 0.05 to 50 Hz frequency band, with *some* real on-resonance motion peaking up above the noise at 0.64 Hz,  0.75 Hz, and 2.1 Hz. The 3.4 Hz mode isn't resolved at all.
    (ii) The estimator super sensor, however, does an awesome job at predicting the M1 motion at these resonances above the first 0.64 and 0.75 Hz pair; it's dramatically less that the OSEM sensor noise. The fits to the GS13 Sus. Point to M1 motion and M1 Drive to M1 motion are quite fruitful. In this f > 0.75 Hz region, you get an interesting mix of GS13 and M1 stage drive, alternating which is better. I'm a little surprised to see a 1.59 Hz mode estimated by the GS13s that isn't otherwise controlled at all, because it doesn't show up in the total M1 drive trace.
    (iii) Below 0.75 Hz -- the estimator seems to show that the M1 motion is completely dominated by suspension point motion. Is that real, or is that GS13 noise? Not so clear with these local metrics. The fact that ASC sees worse noise from 0.1 top 0.3 Hz with the estimator on (see LHO:86507 e.g. SRC2 Pitch Control signals), implies to me that it *is* GS13 noise, and we should still high-pass at least the pitch damping loop controller.

OK. Now that you're used to the noise budget, turn on the comparison of these traces between P & Y estimators ON vs. OFF.
     (i) For the OSEMs, all the can see is the following: the estimators have made the on-resonance motion *worse* between 0.64 and 0.75, and at 2.1 Hz. But -- the OSEMs are still in-loop sensors, so some factors of 1 / (1+G) - like factors may be in play, confusing us as to whether this an artifact of their being less on-resonance loop suppression ... or something. We've gotta math that out still. (Again, the out-of-loop ASC error/control signals shown in LHO:86507 seem to indicate that there is more real on resonance motion, and the OSEMs are faithfully telling us the *change*. The on-resonance story, especially for pitch is going to continue to be "complicated" for a while.
     (ii) Comparison between the bright red vs. bright blue estimated super sensor really shows where we win pitch noise improvement with the P and Y estimators: between resonances in the frequency band between 0.75 and 8 Hz. Since we're using a factor of 5 less OSEMs (aside from on-resonance), the total M1 stage drive motion from the broadband OSEM damping loop drops by factors of 10x.
     (iii) Interestingly, the GS13s still predict suspension point motion to dominate below 0.75 Hz regardless of whether the estimators are on, but the M1 drive signal (unfortunately very subdominant) drops by a factor of 2x ish between 0.1 and 0.3 Hz at the microseism -- and it's by the same ratio of raw-OSEM noise to estimator super sensor / GS13 suspension point prediction. *That* says to me that we *are* doing better with the estimators ON at the useism, vs. what the ASC sensors are saying...

Third Point: Pitch Drive
Now let's switch to the M1 stage drive breakdown for pitch. Here, the comparison is a bit tough to grok immediately, because 
    - With the estimators OFF, you're damping the SUS with -0.5 worth of OSEM broadband damping, but it's split through two paths -- the "classic" broadband path with 0.1 gain, and a "fader" broadband path with gain of -0.4, and summed (thanks linear algebra!).
    - With the estimators ON, the -0.1 gain "classic" path remains, for the other path the OSEMs are now blended to only have -0.4 gain on resonance.
That explains the drive comparison plot then:
    (i) The off-resonance, total requested, M1 drive -- with the estimators ON -- drops as shown in the sensor plot, but does not drop entirely to the noise floor of the GS13 sus. point estimate because -- above 0.75 Hz and off-resonance the stage 1 motion is still limited by the -0.1 gain broadband OSEM path (which doesn't change from ON vs. OFF).
    (ii) The on-resonance story especially at and in-between the 0.64 and 0.75 Hz resonances, remains "interesting" / confusing. There's *more* drive from -0.1 gain OSEM path on resonance with the estimators on vs. off, but difference between the -0.4 OSEM path and full-estimator path drive is better focused on the two resoances, dropping the total-total drive in-between. This is confirming that something in the OSEM sensor path incorrectly sensing the motion in between 0.64 and 0.75 Hz and the -v2 pitch blend filters -- which restore the use of the drive / GS13 FF super sensor for this tiny, in-between frequency band -- is doing the right thing.

Fourth Point: Yaw Sensors
Ok -- now on to yaw sensors. I attach both the P&Y Estimators ON alone as well as ON vs. OFF, but you're good enough at looking at these now and yaw is apparently a much more simple story, so let's just open the ON vs. OFF comparison.  
     (i) The GS13 estimate of the suspension point motion is *much* less than in pitch. The OSEM's don't see anything at all.
     (ii) Above 0.5 Hz, you see off-resonance improvement in the super-sensor estimation of M1 motion by the factors of 4x-5x improvement you would expect from dropping from -0.5 gain (total) usage of the OSEMs to -0.1.
     (iii) This actually advocates for making the blend filter notches in yaw *even skinnier* than the improvement discussed in LHO:86265.
     (iv) I'm not sure this would help, but seeing the estimated suspension point motion peak back above the control noise at 30-40 Hz says to me that (if we can) we should improve the ST0/HEPI feed-forward to ST1 motion for HAM5.  The hump is present even in the Estimator OFF drive trace, so it tells me that the physical motion of the M1 stage is smaller than M1 cage motion. So, we also should consider -- if we can't improve the 30-40 Hz ISI motion (likely), then we roll-off the yaw damping loop controller (definitely easier, we should have plenty of phase margin).

Fifth Point: Yaw Drive
Finally -- the yaw drive. I'm not sure there's too much to discuss here, since the story is more simple and the same as what's seen in the sensors. With the estimator ON, you get the 4x-5x reduction in drive when you're not using the OSEM portion of the estimator.

Summary Plot
Once you're done thinking through it all, it's good to zoom back out and stare so I provide all the plots together -- see 2025-08-25_H1SUSSR3_M1_GS13FFEstimator_LocalPerformance_Summary_QuadPlot.png.
Images attached to this report
H1 SUS
oli.patane@LIGO.ORG - posted 15:09, Monday 25 August 2025 (86554)
Measurement results for SR3 and PR3 Health check transfer functions with 20% P or Y gains

Over the past couple of weeks, I took transfer functions for SR3 and PR3 with different configurations of P or Y damping gain for the estimator, so here are the results for those plus a comparison of their peak locations.

SR3
DAMP P gain at -0.1 (nominally -0.5), other dof gains at their nominal -0.5
Measurements: 86203
Results: /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/SAGM1/Results/2025-08-05_1800_H1SUSSR3_M1_ALL_TFs.pdf r12611

DAMP Y gain at -0.1 (nominally -0.5), other dof gains at their nominal -0.5
Measurements: 86202
Results: /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/SAGM1/Results/2025-08-05_1700_H1SUSSR3_M1_ALL_TFs.pdf r12612

PR3
DAMP P gain at -0.2 (nominally -1.0), other dof gains at their nominal -0.2
Measurements: 86459
Results: /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/SAGM1/Results/2025-08-19_1815_H1SUSPR3_M1_ALL_TFs.pdf r12613

DAMP Y gain at -0.2 (nominally -1.0), other dof gains at their nominal -0.2
Measurements: 86459
Results: /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/SAGM1/Results/2025-08-19_1715_H1SUSPR3_M1_ALL_TFs.pdf r12614

Comparison between SR3 and PR3
Results:
/ligo/svncommon/SusSVN/sus/trunk/HLTS/Common/Data/allhltss_2025-08-25_SR3vsPR3Comparison_DampPat20percent_ALL_TFs.pdf r12615
/ligo/svncommon/SusSVN/sus/trunk/HLTS/Common/Data/allhltss_2025-08-25_SR3vsPR3Comparison_DampYat20percent_ALL_TFs.pdf r12614

Non-image files attached to this report
H1 SQZ
sheila.dwyer@LIGO.ORG - posted 16:56, Friday 18 July 2025 - last comment - 16:02, Monday 25 August 2025(85852)
first look at sqz dataset, limit on IFO to OMC mode mismatch

I've taken a first look at the data that Camilla and Matt took in https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=85813

In the past, I've started modeling these data sets by assuming a fixed arm power, and finding IFO readout losses that are needed to fit the measured shot noise without squeezing at 2kHz.  This time, inspired in part by a comment from Begum, I instead used only the known IFO readout losses and attributing the rest to mode mismatch between the IFO and OMC, this allows us to make an upper limit on the mode mismatch from the IFO to the OMC.

From the google sheet , I will include SRC losses as a known readout loss (although the are listed as sqz injection losses, I think for the IFO they are readout losses), 0.99(SRC)*0.995(OFI)*0.9993(OM1)*0.985(OM3)*0.9904(QPD)*0.956(OMC)*0.98(QE) = 10% known readout losses.  The known injection losses (not including SRC losses) are then 0.985(OPO)*0.99^3 (3 SFI passes)0.99 (FC QPDs)*0.99(other HAM7 loss) *0.99 (OFI)= 7.2%

Fitting the level of squeezing and anti-squeezing at 2kHz suggests an NLG of 13.2 (fairly close to Camilla's measurement of 13.4), and a total efficiency of 0.752 using the Aoki equations (treating mismatches as losses).  Looking at the interactive sqz gui, the IFO to OMC mismatch reduces the measured sqz anf anti squeezing at 2kHz, but the mismatch phase only has an impact below about 400Hz. 

Using only the known readout (10%) and injection losses (7.2%), perfect sqz to OMC mode matching, we can get some limit on the amount of OMC to IFO mode mismatch that can be compatible with our 2kHz squeezing.  5.1% mismatch (which would imply 355kW in the arm cavity) seems too high to be compatible with our squeezing, while a mode mismatch of 3.7% with 350kW in the arm does seem compatible if the sqz to OMC mode matching is perfect. So, we can take 3.7% as an upper limit on the IFO to OMC mode matching that is compatible with known squeezing losses.  The data could be compatible with mode mismatches as low as 2.3% (345kW in arms) without introducing any extra losses.   Any unknown squeezer losses, like excess crystal losses, will reduce this amount.  The arm power of upper limit that we'd infer from this is 350kW, but this depends sensitvely on what we assume the non quantum noise is at 2kHz.  I will try to redo this estimate soon using the cross correlation data that Elenna is working on to have more confident limits on the arm power.

These first two plots show that this model isn't well tuned at a few hundred Hz, I haven't tried to set either the SRCL offset or homodyne angle yet, or the OMC to IFO mismatch phase.  At first glance it does not seem like I will be able to make this match well by adjusting the mismatch phase. 

The last two plots show the squeezing level in dB, just so that we have a plot we can look at.  The script to make these plots are committed here

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 16:02, Monday 25 August 2025 (85942)

Posting this comment which has been saved in my drafts, which I thought I'd posted a while ago:

I've taken a second quick look at this data, constructing a model in the same way that I've done in the past without any mode mismatches.  This works OK, and suggests that for 347kW arm power we'd have 2.5% unknown readout losses and

This data can be fit reasonably well without frequency independent losses, no mode mismatch and an SRC detuning, simliar to previous data sets.  This doesn't mean that there's not a mode mismatch, but there's not new evidence for mode mismatch here.  Kevin did mention that I should look at scenarios where we have both SQZ to OMC mismatches and IFO to OMC mismatch.  Indeed, when I do that the mismatch phase is important for the sqz and anti-sqz level at 2kHz. 

Images attached to this comment
Displaying reports 5061-5080 of 89162.Go to page Start 250 251 252 253 254 255 256 257 258 End