thomas.shaffer@LIGO.ORG - posted 03:11, Thursday 08 December 2016 - last comment - 05:10, Thursday 08 December 2016(32350)
Lockloss @ 11:07

PI mode 27. I damped mode 28 then, thinking that I defeated it, went to get a cup of water. When I returned, mode 27 was quickly rising and I got it to level out but couldn't damp it before it broke.

Comments related to this report
thomas.shaffer@LIGO.ORG - 03:46, Thursday 08 December 2016 (32351)

Back to Observing at 11:45

thomas.shaffer@LIGO.ORG - 04:13, Thursday 08 December 2016 (32352)

Another lockloss at 12:10 due to PI mode 27. I couldn't seem to get it to go down. I could get it to almost level out, but never bring it down. I did not try changing the gain, I will next time.

thomas.shaffer@LIGO.ORG - 05:10, Thursday 08 December 2016 (32353)

Observing again at 13:07. Range says 79Mpc!

H1 General
thomas.shaffer@LIGO.ORG - posted 02:12, Thursday 08 December 2016 - last comment - 02:45, Thursday 08 December 2016(32348)
Lockloss @09:54

It was very sudden. There was no indication form any of the FOMs that anything was, and the environment looks good. There may be the smallest bump on the BLRMS, but nothing that ever should have dropped it. SR3 lockloss template attached, doesn't seem to be the cause (I zoomed in this time unlike before). Also attached the generic lockloss plots, which I can't tell if any of it is out of the norm. Myabe MICH was a bit more active a few seconds before it dropped, but it does sometimes seem to do that normally.

IMC is having trouble staying locked, I should stop writing here and get back to that.

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 02:45, Thursday 08 December 2016 (32349)

Back to Observing @ 10:45

LHO General
thomas.shaffer@LIGO.ORG - posted 00:06, Thursday 08 December 2016 (32346)
Ops Owl Shift Transition

TITLE: 12/08 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 75.5915Mpc
OUTGOING OPERATOR: Travis
CURRENT ENVIRONMENT:
    Wind: 11mph Gusts, 7mph 5min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.24 μm/s
QUICK SUMMARY: Travis delivers a locked IFO again after recovering from an earthquake in China. LLO is currently down. Snow expected in the morning sp be safe driving in.

H1 General
travis.sadecki@LIGO.ORG - posted 00:01, Thursday 08 December 2016 (32345)
Ops Eve Shift Summary

TITLE: 12/08 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 78.082Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY:  Locked for most of the shift with ~1.5 hour downtime due to EQ.
LOG:

See previous logs for pertinent events.

 

H1 General
travis.sadecki@LIGO.ORG - posted 23:39, Wednesday 07 December 2016 (32344)
Observing at 7:39 UTC

No issues with IA or relocking.  Here we go again.

H1 DetChar (DetChar)
vincent.roma@LIGO.ORG - posted 22:50, Wednesday 07 December 2016 (32343)
Dec 1 - 4 LHO DQ Report

The DQ report for December 1 - 4 is online and can be found here.  It's being posted slightly later than normal due to some techincal issues.

Quick Summary:

H1 General
travis.sadecki@LIGO.ORG - posted 22:47, Wednesday 07 December 2016 (32342)
Starting Initial Alignment

IFO alignment looks pretty bad which is to be expected after such a long lock stretch.  Running through IA now.

H1 General
travis.sadecki@LIGO.ORG - posted 22:12, Wednesday 07 December 2016 - last comment - 22:32, Wednesday 07 December 2016(32340)
Lockloss 6:10 UTC

Most likely due to 5.9 EQ in China. 

Comments related to this report
travis.sadecki@LIGO.ORG - 22:32, Wednesday 07 December 2016 (32341)

This lock was 28 hours and 44 minutes.

H1 General (PEM, PSL)
travis.sadecki@LIGO.ORG - posted 22:00, Wednesday 07 December 2016 (32339)
PSL dust monitor continuing to alarm

After JeffB reset the dust monitor alarm level today, the PSL has been intermittently alarming throughout my shift.  Being unable to access the PSL, in addition to being in Observing, I am unsure of what action I can take to investigate this further.

H1 General
travis.sadecki@LIGO.ORG - posted 21:09, Wednesday 07 December 2016 (32338)
Ops Eve Mid-shift Summary

Still locked in Observing.  ~28 hours.

H1 PSL (PSL)
travis.sadecki@LIGO.ORG - posted 17:38, Wednesday 07 December 2016 (32336)
Weekly PSL Chiller Reservoir Top-Off

Added 50 mL H2O to Xtal chiller.  Filters look clean.  Completes FAMIS 6500.

H1 CAL (CAL)
evan.goetz@LIGO.ORG - posted 17:35, Wednesday 07 December 2016 (32329)
GDS filters using incorrect front-end inverse sensing function filter file
Evan G., Jeff K.

Today we identified the H1 parameter file used for the reference model calibration had an incorrect parameter set for loading the inverse sensing function Foton transfer function file. The old file was from pre-ER9 and was when the instrument was running at 50 W. Since we have a different reference sensing function, this file needs to be updated and replaced. This parameter and associated file is only used in the GDS pipeline. Therefore, the EPICS records and front-end do not need to be updated.

Unfortunately, this change means that the GDS pipeline filters will need to be regenerated.

The updated file is stored at: /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/Measurements/Foton/2016-12-07_H1CALCS_InverseSensingFunction_Foton_SRCD-2N_Gain_tf.txt

The parameter file has been updated to include this. The reference model parameter files should now be:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/Common/params/IFOindepParams.conf (rev3829)
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/params/H1params.conf (rev3922)
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/params/2016-11-12/H1params_2016-11-12.conf (rev3855)

The first attached figure is a comparison of the old inverse sensing function / correct reference inverse sensing function. The low-frequency change is because running at 30 W vs 50 W causes ~2-3 Hz shift in the detuned SRC spring frequency. The mid and high frequency change is because the coupled-cavity pole frequency is different by ~5 Hz and there is a small change in the overall gain, ~5%

Fortunately, we expect the inspiral range computed from GDS to increase. This is because the correct inverse sensing function is smaller than the old inverse sensing function. Since the calibration works as DeltaL = (1/C)*d_err + A*d_ctrl, then with a smaller, correct (1/C), we expect that the displacement noise to be smaller than with the old, incorrect, and too large (1/C). We expect that this may correct some of the discrepancy observed between the GDS pipeline and front-end calibration as shown by the inspiral range (second attached figure). However, we do not think that all the discrepancies will be corrected between the GDS pipeline and the front-end calibration (see third attached figure).
Images attached to this report
H1 ISC (GRD)
sheila.dwyer@LIGO.ORG - posted 17:17, Wednesday 07 December 2016 - last comment - 12:09, Monday 16 January 2017(32334)
changes to make locklosses less violent

While we were out of observing I did a few quick things to try to make our locklosses a little gentler.  (part of WP 6391)

First, I set limits on the TR QPD pit and yaw signals of 2, rather than 100 which were the previous limits.  These shouldn't go above 1 if we are locked, but can become large after a lockloss and send large signals to the suspensions through the soft loops.  I accepted the new values in SDF so we could go back to observe.

I did a little bit of work on the down state of the ISC_LOCK guardian, and loaded some of the changes.  

We can see if this makes things better for the next lockloss.  

Comments related to this report
sheila.dwyer@LIGO.ORG - 12:09, Monday 16 January 2017 (33341)

A comment to make this alog easier to search.  This is related to Borja's study of signals durring locklosses, and Anamaria's entry about locklosses at LLO

32831 

29111

LHO VE
chandra.romel@LIGO.ORG - posted 17:05, Wednesday 07 December 2016 - last comment - 17:07, Wednesday 07 December 2016(32332)
CP4 sensor

We are leaving the gas N2 bottle connected to lower sensing line overnight. I lowered the N2 line pressure from 180 psig to 100 psig and re-connected the rotameter and adjusted it so if the blockage does break loose flow into LN2 reservoir will be limited to 3 LPM.

Attached is photo of pressure regulator values for Kyle and John. ;)

I will finish installing TCs tomorrow and hope my fingers don't fall off in the process.

Images attached to this report
Comments related to this report
chandra.romel@LIGO.ORG - 17:07, Wednesday 07 December 2016 (32333)

I also lowered CP4 LLCV to 38% open because exhaust pressure was reading 0.3 psig when we expect 0 psig with bypass valve open.

H1 SUS (CDS, DetChar, Lockloss, SUS)
jeffrey.kissel@LIGO.ORG - posted 16:54, Wednesday 07 December 2016 - last comment - 17:35, Wednesday 07 December 2016(32328)
SR3 Glitch Lockloss: The Investigation Continues
J. Kissel (B. Weaver, S. Dwyer)
FRS Ticket 6852

It was recently identified that a Dec 05 lock loss looked suspiciously cpoincident with a glitch in the H1 SUS SR3 M1 T1 and LF OSEMs (see LHO aLOG 32220). The same OSEMs were suspected in a subsequent Dec 06 lock loss (LHO aLOG 32251), and thus an FRS ticket was filed (FRS Ticket 6852), but was later deemed too confusing to draw conclusions (see brief mention of it in LHO aLOG 32279).

Betsy then went back to find the minute trends of the SR3 OSEM noise appeared suddenly louder after the Dec 05 glitch/lock loss in a 5 day trend surrounding the glitch (split into LHO aLOGs 32280 and 32281).

In this aLOG, I investigate further by zooming into 10 minutes surrounding the Dec 05 glitch. I attach three plots:
- A 10 minute trend of second trends for the suspect channels, both in terms of uncalibrated EPICs records (the same that Betsy chose to use in her aLOG) and in calibrated fast channels (stored at 256 Hz). The EPICs records show a similar sudden increase in amplitude of max and min trends, but the calibrated fast channels do not. T1 shows a much larger increase in max/min noise than LF.
- A full-data time-series of the same to channels in the same two formats. Same thing here regarding the sudden increase in noise in T1 INMON, but only a brief glitch in LF's INMON. Again, no such obvious change in behavior on the fast channels. Interestingly, it looks like there's smaller glitch in T1's fast channel 107 [sec] earlier.
- An amplitude spectral density of the calibrated fast channel before and after the glitch happens (15:57 UTC vs 16:06 UTC, 0.04 Hz BW ASD). There's no obvious difference between these spectra. This points to either the excess noise showing up in the INMONs is at higher than ~100 Hz, or the EPICs records are just reporting bogus information. Because I'm suspicious of the apparently incredibly low microseism, I also attach BLRMS of the microseism on the ground and on the ISI around this time. Indeed, the GS13s seem to confirm that the RMS velocity is somewhere around 5 [nm/s], which is roughly equivalent to ~5 [nm] at 0.15 Hz, which in the right ballpark of what the OSEMs report of 2-4 e-3 [um] or 2-4 [nm] or 2-4 [nm/s].

In conclusion -- still no evidence for anything more than a one-time glitch, and there is now little-to-no evidence for permanently different noise behavior after the glitch. We need to wait for more occurances of this issue with obvious evidence before we go for making any change to the instrument.
Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 17:35, Wednesday 07 December 2016 (32335)

This is something that I think has definitely happened twice:

In the example from Dec 5th, it is clear that there is a glitch in T1 and LF, on Dec 6th it is not clear which osem to blame, but it is clear that SR3 moves before the lockloss (see this plot).  We don't send any ISC feedback to SR3, and I already checked that the cage servo isn't glitching in either case, so this is most likely a problem that comes from the top mass damping.  

Displaying reports 58041-58060 of 89511.Go to page Start 2899 2900 2901 2902 2903 2904 2905 2906 2907 End