hugh.radkins@LIGO.ORG - posted 10:42, Wednesday 09 April 2014 (11243)
WBSC10 ETMY SEI HEPI Position Loops closed--Revisit

So we ran overnight at ETMY with the HEPI position loops on.  I've revisited the data I posted yesterday morning.  In the attached plot I've added some of last night's overnight running with the loops on.  The dashed lines continue to be the off loop reference from ~2AM Tuesday, The solid line references(REF17+) are with the loops on but starting about 8am Tuesday, possibly a noisier time.  The current traces are from 2AM Wednesday with the loops on.  It is involved but my simple analysis says that some places are worse with it on and at another time it is better suggesting it is just dependent on the ground motion at the time.

When I started the loops yesterday I just put the current positions into the Target. From my log I put in 12 March, the Target positions should zero.  The differences are 57 to 30 ums in position,  11urads tilt, and <7 urads Rz.  The HEPI Position at ETMY is ready for controlling as needed; so if the current position is not close enough, go for it.

Images attached to this report
LHO VE
john.worden@LIGO.ORG - posted 10:02, Wednesday 09 April 2014 (11241)
Y2 Beam Tube accumulation

Partway through our accumulation on Y2 - strange CC gauge behavior on one gauge and different rate of rise on another.

We might have a small leak at our RGA setup - will check at the end of accumulation.

Images attached to this report
H1 CDS
james.batch@LIGO.ORG - posted 08:49, Wednesday 09 April 2014 (11238)
Matlab 2012b for control room
The default version of Matlab for the control room is now 2012b, as it was previous to Tuesday's internet outage.
H1 SEI
hugh.radkins@LIGO.ORG - posted 08:12, Wednesday 09 April 2014 (11237)
LVEA Entry 0742--0748 pdt---WHAM4 HEPI H1 Actuator back in Run mode

So this actuator got 17+hours of bleeding, hopefully sufficient.  Shoot, I forgot to grab the serial number again.  Replacement SN is 22952

H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 08:02, Wednesday 09 April 2014 (11236)
CDS model and DAQ restart report, Tuesday 8th April 2014

no restarts reported. 

H1 CDS (SYS)
david.barker@LIGO.ORG - posted 07:56, Wednesday 09 April 2014 (11235)
network connection has been restored to site

Report from Richard McCarthy:

The site contractor was able to make repairs to the fiber and our
network services and phones have been restored as of ~3 AM today. 

H1 SUS
sheila.dwyer@LIGO.ORG - posted 17:27, Tuesday 08 April 2014 (11232)
noise on ETMX L1 LR drive

Before we understood that the noise we were seeing was the bounce and roll modes of ETMX (see alexa's alog) we were looking around at Osem signals, and we saw that there is a large peak at around 25 Hz in L1_VOLTMON_LR_DQ.  It was there before the bounce and roll modes were rung up, an it is there with damping on and damping off. 

Images attached to this report
H1 ISC
alexan.staley@LIGO.ORG - posted 17:17, Tuesday 08 April 2014 - last comment - 09:24, Wednesday 09 April 2014(11221)
Noise Hunting

(Sheila, Alexa)

We have been trying to search for the 1/f feature present at 1-50Hz in the noise plots. We tried a few different things as described below. The noise spectrum under nominal conditions is represented in REF0-2.

  1. Hepa fan on/off on ISCTEX:  We turned the HEPA fans on and noticed that the 1/f feature appeaared to be upconverted; the noise improved around 1 Hz, but got worse from 5-50Hz (see REF 3-5).
  2. Modulation frequency: Under the nominal conditions the modulation frequency is at 24.407363MHz with a 12dB attenuator. We changed the attenuation in this path several times and found no noticable/significant difference in the noise.
    • 6dB attenuation  --> REF 6-8
    • 0dB attenuation ---> REF9-11
    • 18dB atttenuation --> REF 12-14
  3. Laser power: The nominal power after the second faraday is 53mW; the nominal power at the bottom periscope is 47mW. We adjusted the HWP before the faraday to reduce the power at the second faraday to 25mW. We found that the noise increased by a factor of 2 from around 4Hz to 50Hz as seen in REF 15-17.

All these plots can be found under /ligo/home/sheila.dwyer/ALS/HIFOX/COMM/COMM_COherences_April8.xml. In the set of three, the first reference is always the power spec, the second the RMS, and the third a coherence plot. I have attached an image which shows the nominal power spectrum and the cases with the HEPA fan on and one with the power reduced (NoiseSearchPic1).

 

For future improvement of the QPD servos, we adjusted the input beam onto the QPDs with the servo off, such that the beam was fairly centered onto both QPDS. We did not get a chance to work on the actual servos though.

We proceeded to do some more noise hunting, but halted the effort when we saw two new spikes in the noise spectra. One spike was at 9.8Hz and the other at 13.8Hz (see second png). Turns out these are the bounce and roll modes of the suspension that must have got rung-up during an ISI trip. (Refer to Sheila's alog).

Images attached to this report
Comments related to this report
alexan.staley@LIGO.ORG - 21:46, Tuesday 08 April 2014 (11234)

(Sheila, Chris, Alexa)

Since we had seen a difference in the 1/f noise by decreasing the laser power at EX, we decided to try the following -- we placed an ND filter in the path of the x-arm green transmission on ISCT1. With the ND filter the ALS-C_TRX counts dropped from 0.94 to 0.471. We saw an increase by a factor of 2 in the 1/f noise. We would expect a factor of Sqrt(2). We should repeat this measurement by decreasing the power further. The red line in the attached figure is the nominal spectra; while the light blue line (REF 27) is with the ND filter in place. (Overall these spectra look higher then those posted earlier in the attached alog; it's possible that this change came from alignment drift).

 

Subsequently, we decided to look into the noise at the COMM BBPD.

Signal from the PD w/ no RF pre-amp @ 100Hz BW:

  • signal carrier: -33dBm
  • secondary peak due to RF pick-up: -73dBm
  • shot+dark noise/analyzer limit: -100dBm

With PD blocked and no RF pre-amp @ 100Hz BW:

  • RF pick-up signal: -69dBm
  • noise floor: -100dBm

With PD blocked and RF pre-amp (+13dBm) @ 100Hz BW:

  • noise floor: -93dBm
  • RF pick-up had several peaks: -51dBm, -59dBm, -60dBm, -61dBm

Instead of using the beatnote signal from the PD, we used a signal generator (-31dBm at 79.8Mhz) to lock the PLL and measured the in loop noise spectrum (with the input gain of the PLL at -25dB w/ the two compensation filters off). We will posts plots tomorrow. At first glance; however, this does not appear to be the 1/f noise source we have been hunting.

Images attached to this comment
alexan.staley@LIGO.ORG - 09:24, Wednesday 09 April 2014 (11239)

I have attached the plots and data we collected last night. The noise spectrum was measured out of IMON of the PFD with the PLL locked to a signal generator instead of the PD signal. This noise spectra is loop suppressed by the COMM PLL loop. The COMM PLL had an input of -25dB with the two common filters off (unlike the nominal settings). We took a OLTF of this modified loop.

Non-image files attached to this comment
H1 SEI
hugh.radkins@LIGO.ORG - posted 17:05, Tuesday 08 April 2014 (11231)
LVEA HEPI Pump Controller Found Not Running

The corner station controller medm was found white boxed.  The computer (h1hpipumpctrll0) was running--we did not have to restart it.  However, the servo program was not running.  It has been down since early Sunday morning.  The VFD was running at 31.xx Hz, the last value it received.  System was recovered in the best way possible:

Restarted servo--see wiki.  This database does not process any records when started and begins in manual mode, so even though its output is zero, it actually hasn't written anything to the VFD at this point and it continues driving the pump motors at 31hz.

The Servo motor speed slider was then rapidly dragged to the nominal running output for 80 psi.  You can look in the trends at the CONTROL_VOUT channel, for the LVEA system it is ~1080.  If you are dexterous enough, this will only slightly glitch the system if at all.  I got lucky and saw no pressure drops.

Once pressure is steady, tweek the output til 80psi.  Put 80 psi in the Setpoint (it is zero'd with the database restart.)  Engage the Servo (push the On button.)

H1 SEI (CDS)
david.barker@LIGO.ORG - posted 17:04, Tuesday 08 April 2014 (11230)
ISI HAM5 binary output problems

Following the h1isiham5 model change last friday to correct the BIO card assignments, Jim W reported continuing binary output switching problems with h1isiham5.

We have found the problem.

The drawing D1000298 shows the following:

The IO Chassis has two BIO cards installed. Each card has an input and output connector, each connector pig tails to two cables (lower 32 channels and upper 32 channels). 

The CER rack has two binary input chassis installed (one for ham4 and one for ham5) and only one binary output chassis shared between the two chambers (ham4 uses lower 32 channels, ham5 uses upper 32 channels).

So the inputs are straight forward, CARD0 both cables go to the back of ham4 binary input chassis, CARD1 both cables go to the back of the ham5 binary input chassis.

The problem is with the binary outputs. The drawing shows that CARD0 lower 32 cable goes to the lower 32 of the binary output chassis and the upper 32 cable is not used. With CARD1, lower 32 cable goes to the upper 32 of the binary output chassis and the upper 32 cable is also not used.

We found that CARD1 binary output is missing its cable, and both cables from CARD0's output go to the output chassis. In other words ham4 gets two cables and ham5 gets none. The fix is to run a fourth cable to the CARD1 output, and use its lower32 for the output chassis upper 32 connector.

The h1isiham5 model is in agreement with the drawing, so no software change is needed.

LHO VE
kyle.ryan@LIGO.ORG - posted 16:13, Tuesday 08 April 2014 (11229)
Inadvertently de-energized 12V power supply beneath BSC6 -> Plugged back in


			
			
H1 ISC
alexan.staley@LIGO.ORG - posted 16:03, Tuesday 08 April 2014 - last comment - 16:52, Friday 11 April 2014(11228)
HEPI and ISI ETMX Tripped

(Rich M, Sheila, Alexa)

 

HEPI and ISI ETMX tripped because we were playing with the suspension watchdogs.

Comments related to this report
sheila.dwyer@LIGO.ORG - 17:47, Tuesday 08 April 2014 (11233)

We had a hard time recovering from this trip which caused several more trips, the wd plotting script is not working this afternoon, possibly beause of our network problems so we don't have any plots.  Once HEPI was isolated, we tried letting guardian isolate the ISI. It tripped immediately on CPSs (stage1) after we cleared this and tried again it tripped on GS13 (stage2). 

We then paused the guardian, moved all the blends to start, and gave the gaurdian another try. (note, the ground motion is fairly quiet today).  This tripped again, GS13s. 

We then puased the guardian, and tried the command script, stage 1 level 3, tripped on the actuator limit.  I then stopped taking notes. 

The rough procedure that Rich used to bring it back was damping both stages, turning on 1 DOF at a time RX, RY, Z, RZ, X, Y (stage 1 first, then stage 2).  Then Alexa moved the blends over to Tbetter without anything tripping. 

We don't know why the things that used to work don't anymore, but now ETMX ISI is harder to untrip and neither the guardian nor the command script seem to be able to do it anymore. 

Rich may not have mentioned in the alog, but after our trip the other day while trying to switch blends, he changed the filters from zero crossing to ramp, which should make it easier to switch blends without tripping the ISIs. 

One thing about guardian, its not clear to me how we should unpause if we need to pause it for some reason.  TO pause it we paused all three, stage 1, stage2 and the manager.  Wen unpausing the subpodinates they don't come back in managed mode.  I was able to get them back to managed mode by going to init on all three, but in the meantime they were doing their own thing, but happily didn't trip the ISI.  What is the best way to do this?  Also, maybe the right way to pause and unpause a manager with subordinates is something that needs to be made more obvious to a user. 

Alexa also tried pausing, she only paused the manager, bringing that back was not a problem but it doesn't pause the subordinates.

jameson.rollins@LIGO.ORG - 11:41, Wednesday 09 April 2014 (11246)

quoth Sheila:

We don't know why the things that used to work don't anymore, but now ETMX ISI is harder to untrip and neither the guardian nor the command script seem to be able to do it anymore. 

But you did mention one likely important thing that changed: new blend filters (Tbetter?).  What happens if we go back to Tcrappy?  Do we have the same problems?

also quoth Sheila:

One thing about guardian, its not clear to me how we should unpause if we need to pause it for some reason.  TO pause it we paused all three, stage 1, stage2 and the manager.  Wen unpausing the subpodinates they don't come back in managed mode.  I was able to get them back to managed mode by going to init on all three, but in the meantime they were doing their own thing, but happily didn't trip the ISI.  What is the best way to do this?  Also, maybe the right way to pause and unpause a manager with subordinates is something that needs to be made more obvious to a user.

Alexa also tried pausing, she only paused the manager, bringing that back was not a problem but it doesn't pause the subordinates.

This is definitely sounds like something that could be improved.  It is true that all nodes, manager and subordinates, need to independenty be paused and unpaused.   I'll try to think about how to make that smoother.  In the mean time, here's the procedure that should be used:

  1. pause the manager
  2. pause each of the subordinates (ISI_ST1/2).  order does not matter
  3. ...do work...
  4. request the INIT state in the manager while it's still paused
  5. unpause the manager

The manager INIT state resets all the works, restarts them, and puts them into managed mode.  That should be the most straightforward way to do things for the moment.

sheila.dwyer@LIGO.ORG - 12:19, Wednesday 09 April 2014 (11248)

Thanks Jamie.  

We did try both the command script and guardian with all the blends on start, which used to work.  I don't think we tried turning sensor correction off, which is another change.  

stefan.ballmer@LIGO.ORG - 16:52, Friday 11 April 2014 (11301)SEI
I heard that rumors were spread that this alog was written during an earthquake that we hadn't noticed, so there is no reason to worry about our inability to use guardian or the command scripts to reisolate ETMX.  

That is false, there was no earthquake.  

PS, this is sheila, still loged in as Stefan. 
H1 CDS
james.batch@LIGO.ORG - posted 15:56, Tuesday 08 April 2014 (11227)
Matlab changed versions temporarily
Matlab has been changed to a 2011a version with limited licenses available for Linux control room workstations.  Avoid using matlab for model changes.  Version 2012b will be reinstalled when licenses become available.  No matlab licenses are available for OS X at this time.
H1 General
jeffrey.bartlett@LIGO.ORG - posted 15:54, Tuesday 08 April 2014 (11226)
Ops Summary
LVEA Laser Hazard

Nitrogen delivery to Mid-X
Ed Watt – Insulation on X-Arm

08:45 Jodi – Working at Mid-Y
08:45 Ken – Replacing flow bench fan motors in Optics Lab
08:57 Filiberto – Camera work at End-Y
09:38 Sheila & Alexa – Alignment work at End-X
09:30 Corey – Survey of ITMX spool cameras
09:42 Schneider Electrical contractor on site working on GC UPS system with Richard
09:50 Jonathan – Restarting the aLOG
09:50 Aaron – Cabling work in LVEA
10:00 Rick, Justin, Peter & Cris – Cleaning up in the H1-PSL enclosure
10:04 BSC2 – HEPI & ISI watchdogs tripped
10:06 BSC1 – SUS, HEPI, & ISI watchdogs tripped
10:15 Schneider Electrical contractor on site working on CDS UPS system with Richard
10:30 Praxair – Nitrogen delivery to Mid-X
11:25 Cyrus – Outside internet & phones are down due to fiber & copper cut at 400 area
12:30 Betsy & Travis – Working in the LVEA SUS Test Stand area
12:30 BSC9 – SUS, HEPI, and ISI watchdogs tripped
12:50 Richard – Changing dust monitor #5 (Beer Garden) to fixed vacuum connection
12:54 Corey – Going to End-X TMS lab
13:15 M itch & Scott – Taking forklift to Mid-X to get BSC plates
13:20 Corey – Going to End-Y
13:30 Michael – Survey tour in LVEA
13:35 Hugh & Greg – Replacing parker valve at HMA4
13:40 Cyrus – Going to End-Y
13:45 Richard – Working on dust monitor #5 tubing
14:06 Alastair & Dave – Turning on CO2 TCS-X laser 
14:20 BSC2 – HEPI, ISI watchdogs tripped – Ken working on cabling near BSC2
14:44 Kyle – going to End-Y working on BSC6
H1 SEI
jeffrey.bartlett@LIGO.ORG - posted 15:23, Tuesday 08 April 2014 (11225)
BSC2 & HAM3 Watchdog Trip
@ 14:20 the BSC2 HEPI and ISI watchdogs tripped. Shortly after the HEIP watchdog on HAM3 tripped. There was work on the cable trays above these chambers at this time. Both chambers have been recovered. 
H1 ISC
sheila.dwyer@LIGO.ORG - posted 19:50, Monday 07 April 2014 - last comment - 10:25, Wednesday 09 April 2014(11211)
ALS work today

Sheila, Chris, Alexa, Stefan

This morning we looked for coherences with many signals with our COMM noise.  There weren't any surprises, we see the same coherence with the end station PDH control signal around 1kHz that we are used to, ISCT1 accelerometers around 70-100Hz, and a little coherence (-0.7-0.9) with the oplevs at low frequencies (pitch at 0.5Hz, yaw around 0.1).  We don't see much coherence at all with the TMS QPDs, just a small bit at low frequencies.  We lose coherence with the in loop sensor below around 100Hz.  

Chris and I went out to End X to look into the beam quality problems.  We didn't find much that was promising.  We checked rather carefully for clipping on the way into the chamber again.  We also set up the nanoscan again, and we see that there really isn't anything coming back to the WFS when the ITM and the ETM are both misaligned (so it isn't a second beam that is directly reflecting a lens or some optic on transmon.)  

We also tried Daniel's suggestion of closing down an iris in the path.  For WFS B this only made things worse.  WFS A scans will be attached to this alog soon, but we didn't get any improvement there either.  

We came back and tried out some of Rich's blends.  We were able to get relatively low noise once without using WFS, 30z down to 0.02 Hz. The attached plot shows the COMM noise (measured by the IR) with different blends on.  We are curently seeing a lot of noise on ETMX T240s at around 3Hz, (100 times more) Rich is looking into this.

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 10:25, Wednesday 09 April 2014 (11242)
Non-image files attached to this comment
Displaying reports 77261-77280 of 88171.Go to page Start 3860 3861 3862 3863 3864 3865 3866 3867 3868 End