Reports until 22:53, Thursday 20 March 2014
H1 ISC
keita.kawabe@LIGO.ORG - posted 22:53, Thursday 20 March 2014 - last comment - 08:41, Friday 21 March 2014(10913)
Done with TMSY alignment (Jax, Corey, Keita)

Using the green beam retro reflected by ETMY leaking into IR path, we found that the IR QPD path was off in YAW. I don't understand why/how, nobody touched this path since HIFO days, and this path worked in HIFO.

We fixed the problem by turning the pico mirror in the IR QPD path. Just tweek one mirror, and both of the QPDs were fixed.

Details:

There are many many many ghost beams because the reflectivity of IR HR for green is lower than that of IR AR, so we used foils to block ghost beams. It is easy to see the correct beam on QPDB, but was impossible to see the correct one on QPDA as the IR 50:50 acts as a good AR for green. Therefore, for QPDA, we looked at one specific ghost beam and used Kiwamu's calculation to set the ghost beam position right. At first both of the QPDs were off in the same direction by about the same amount. We twisted the TMS by giving it a bias offset and were able to bring the beam on QPDs to correct position. We removed the bias, tweaked one pico mirror until the beam positions were good. Unfortunately the green thing is so dim we couldn't see anything on the IR QPDs.

Comments related to this report
keita.kawabe@LIGO.ORG - 23:00, Thursday 20 March 2014 (10914)

I noticed that one of the thicker cables running from the TMS ISC table to the top mass was half coming off of a J-clip on a post on the TMS ISC table on its own. I pushed the cable back in, and this made a large impact on the PIT of TMS such that we needed to rebalance.

There is some tension in the cable and this might be good enough to force the cable in the long run to creep out of the clip. Since the cable is stiff, once it changes its position there is an impact on the TMS balance. This might be the cause of mystery alignment jumps in OAT and HIFO days (i.e. cable creeps out of J-clip and settles to a new position).

We need to tighten J-clip some more tomorrow.

keita.kawabe@LIGO.ORG - 23:02, Thursday 20 March 2014 (10915)

Remaining tasks tomorrow:

  • Tighten J-clip on the post, rebalance TMS if necessary.
  • Test Picomotors.
  • Test beam diverter reed switches (beam diverter moves, but we never looked at the readback).
  • Look for obvious interference, cable rubbing etc.
  • Re-center BOSEMs.
corey.gray@LIGO.ORG - 08:41, Friday 21 March 2014 (10920)

Here are a few photos from Thursday work.  Took photos of Green beam on the Telescope mirrors, as well as our "bolt weight" which has a new position.

Images attached to this comment
H1 SUS
arnaud.pele@LIGO.ORG - posted 20:30, Thursday 20 March 2014 (10912)
ETMX P2P Y2Y

After this morning's adventure with the ETMX UIM driver, and thanks to Richard's help to fix it, I could take UIM to test mass pitch and yaw transfer functions. Drivealign filters were then designed in the same manner as Keita with the measurements from this morning. The last two pdf show the filter design, with the filter in cyan.

They are now installed in the L1 P2P and Y2Y drivealign matrix filterbank with a gain of 1, but need to be tested.

UIM data used for the fitting are under the svn and located in :

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGL1/Data
2014-03-20_H1SUSETMX_P2PY_WhiteNoise.xml
2014-03-20_H1SUSETMX_Y2PY_WhiteNoise.xml

Since the top mass P2P and Y2Y drivealign filters disappeared, I reinstalled them, and the first two pdfs are showing the design.

Non-image files attached to this report
H1 AOS (ISC, SUS)
sheila.dwyer@LIGO.ORG - posted 19:32, Thursday 20 March 2014 (10911)
OpLev damping on ETMX

Arnaud, Sheila

Today we worked on the OpLev damping more, including making the modification to the etmx and Itmx models needed to route the damping through the drivealign matrix for both PUM and UIM.  These models (h1susetmx and h1susitmx) committed to svn.

The problem with the pitch loop saturating the DAC was the high frequency noise, as Keita suggested.  I added a low pass at 10 Hz, and now the loop runs with the intended gain without saturating the DAC.  The first screen shot attached shows the coil driver outputs with the loop in last night's configuration (dashed lines), and with both PIT and YAW damping loops engaged (solid lines).  (The max is 130000 counts). 

The next plot shows the performance of these loops (blue is both loops on, red is neither on).  We get a factor of 5 improvement at 0.45 Hz in Pitch, and a factor of 10 at 0.13 Hz in Yaw.  The Pitch RMS is reduced by 60%, while Yaw rms is reduced by 50%.  

The Pitch loop gain is half of what I had originally indented, the current set up is shown in the attached screen shot. 

Images attached to this report
H1 ISC
jaclyn.sanders@LIGO.ORG - posted 18:32, Thursday 20 March 2014 (10890)
ISCTEY progress report and power budget, with bonus TMS offsets

While Corey and Keita were aligning the TMS, I kept myself busy touching up some of the alignments and clean-up tasks on ISCTEY. The refl path and WFS paths are nominally aligned, and I've observed that without my favorite anthropogenic noise sources in the chamber, the return beam is relatively stable.

I'm working with TMS offsets of PIT 20 urad, YAW 9 urad. Not all that bad.

IR:

I adjusted the polarization on the IR Path from its initial position to something closer to the nominal power given in the ISC End Station manual.

Also, my earlier concerns about the shorted power cable damaging the BBPD appear to be unfounded... that factor of 10 I had to add to the impedance was nicely accounted for by the gain switch on the hardware PD interface, which I had completely forgotten existed.

  power
Laser output enough*
After attenuation 38.7 mW
IR mon PD 310 uW
BBPD 18.4 mW

*this power meter's filter didn't make it into the storage bag, no chance of measuring this one with the tools I have right now.

Green:

PD4 is aligned to the rejected Faraday beam. At this moment, the polarization coming from the laser in relation to the first Faraday appears to be slightly different from EX; I'm consistently measuring ~1.2% power rejected to EX's 1.9%. I've also adjusted the laser current to increase power to the chamber; I'd had it turned down to 0.97 A in an attempt to find the beatnote, and the polarization of the laser wasn't optimal for getting power into the rejection beam (it was initially about ~0.4% of input power). This may be why I was having such a hard time aligning PD4 earlier, there wasn't much there to find.

Also the REFL_A PD might need 

  power
Laser output 53 mW
After 1st Faraday 49.1 mW
On mon PD 700 uW
After 2nd Faraday 41 mW
At periscope 40 mW
At REFL_A PD 12.87 mW**

** at the PD I'm seeing flashes up to ~5 mW. Unclear if this is an alignment or calibration issue, will be tracking this down tomorrow.

H1 CDS
cyrus.reed@LIGO.ORG - posted 18:04, Thursday 20 March 2014 (10909)
CR Workstation Updates

I took advantage of an unusually quiet control room to apply updates to any available worksations.  Updates have been run on opsws1-6, opsws8-10 (vm), operator0, and vacuum1.  Additionally, opsws1-6, operator0, vacuum1 and alarm0 were moved to the new workstations subnet.

opsws0, opsws7, and operator1 still require the latest os updates.  Of these, opsws0 and operator1 still need to be moved to the workstations subnet.

H1 SEI (INS, ISC)
hugh.radkins@LIGO.ORG - posted 16:34, Thursday 20 March 2014 - last comment - 18:33, Thursday 20 March 2014(10908)
ETMY HEPI TF scheduled to run about 630pm tonight, untrip SUS & HEPI Please

If the crew leaving EndY could ensure the SUS is damped and the HEPI watchdog is untripped, it would be much appreciated.  ISI is locked and can be as is.  Thanks, Hugh

Comments related to this report
jaclyn.sanders@LIGO.ORG - 18:33, Thursday 20 March 2014 (10910)

As of 6:30 PM, HEPI watchdog is untripped and SUS is damping. She's all yours.

H1 General
jeffrey.bartlett@LIGO.ORG - posted 16:00, Thursday 20 March 2014 (10907)
Ops Summary
LVEA Laser Safe

Hugh – Adding payload to HAM5
Aaron – Pulling cables HAM3, HAM4, & BSC3
Apollo – Drilling in LEVA wall for nitrogen line installation

09:42 Keita & Corey - Working on TMS at End-Y
10:05 Sheila – Restart ITMX model 
10:26 Jim – Shutdown OAF
10:30 Richard – Adding ADC card to OAF
10:43 Hugh & Apollo – Adding Payload to HAM5 – Using Forklift
11:20 Jim - Restart OAF
12:00 Praxair – Delivering nitrogen
12:50 Filiberto – Going to End-Y and End-X to pick up items
12:50 Karen – Cleaning at End-y 
13:20 Patrick – Taking down conlog for backup
14:00 Travis – Working in SUS LVEA cleanroom
14:13 Gerardo – Working in the H2 Laser enclosure
14:33 Craig – Working in the H2-PSL
14:35 Richard – Going to End-X
15:30 Sheila – Restart ETMX model 

H1 SEI (INS)
hugh.radkins@LIGO.ORG - posted 15:45, Thursday 20 March 2014 (10906)
WHAM5 ISI Optical Table Payloaded with ~600lb iLIGO Leg Element

This completed the need for forklift action at HAM5 for the time.  The Mass was placed on six 1"x1"x1/16".  Will continue payloading (lighter stuff.)

Scott, Bubba, Hugh

H2 SEI (SEI)
mitchell.robinson@LIGO.ORG - posted 15:25, Thursday 20 March 2014 (10903)
Staging building, 3IFO (unit 2) progress
Jim, Mitchell
The down facing optical table is now parked on the granite table anxiously awaiting Apollo on Monday. The up facing is on the assembly stand also ready for action.

As for unit 2 the small and large horizontal actuators have been installed. Stage 1 doors prepped. Horizontal L4-C's have also been installed. Some of the blade bending fixtures have been added. 
H1 ISC
sheila.dwyer@LIGO.ORG - posted 15:18, Thursday 20 March 2014 (10902)
TMSX alingment

I redid the baffle PD alignment,

Baffle PD 1: 208.4P -234.0Y

Baffle PD4: 278.4P -297Y

Alinged 243.4P -265.5Y

Change from saved: +5 PIT +1 Yaw

PR3 (-245 PIT -250.3 Yaw) hasn't changed.

H1 SUS
arnaud.pele@LIGO.ORG - posted 13:57, Thursday 20 March 2014 - last comment - 15:36, Thursday 20 March 2014(10898)
ETMX L1 OSEMs

[Richard Arnaud]

This morning while taking measurements on UIM ETMX, I saw all four L1 osems readback were zeros. Looking at the past data, signal stopped at ~10:51 am PT. Richard and I went to the end station, and saw that the UIM coil driver switch was mysteriously turned off... After turning it back on, sensing and actuating now work again.

Comments related to this report
arnaud.pele@LIGO.ORG - 15:36, Thursday 20 March 2014 (10905)

Richard went back to the end station after lunch and found the hardware switch of the UIM driver turned off again, whereas nobody physically turned it off.

H1 SEI
jeffrey.bartlett@LIGO.ORG - posted 13:27, Thursday 20 March 2014 (10897)
Payload HAM5
10:45 to 12:00 Hugh and Apollo using fork lift to add payload to HAM5.
H1 CDS
patrick.thomas@LIGO.ORG - posted 13:23, Thursday 20 March 2014 - last comment - 15:12, Thursday 20 March 2014(10896)
Conlog stopped to start full backup
No channel value changes are being recorded for the duration of the backup.
Comments related to this report
patrick.thomas@LIGO.ORG - 15:12, Thursday 20 March 2014 (10901)
The good news is that the backup took only about 20 minutes. The bad news is that it took a lot longer to restart conlog. At startup, when it tried to add the last shutdown time to the database, it reported errors of the type: 'The total number of locks exceeds the lock table size' and quit. Adding 'innodb_buffer_pool_size=1G' to '/etc/mysql/my.cnf' and then restarting the computer seems to have fixed it, but I'm not sure what other implications this may have. I think I'm going to have to rethink how I record the shutdown times in the database.
H1 AOS (SUS)
jeffrey.kissel@LIGO.ORG - posted 19:01, Wednesday 19 March 2014 - last comment - 13:48, Tuesday 25 March 2014(10881)
H1 ETMX Optical Lever Confusion
Has the analog whitening settings changed on the ETMX optical lever? I've compared a high-frequency spectrum with a measurement I took in February, and there's reported tons more motion above 2 [Hz], when the ISI motion is roughly equivalent if not better at these frequencies (see attached). Looks there's an extra 1:10 analog filter that's not being compensated or something...
Non-image files attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 15:28, Thursday 20 March 2014 (10904)

Looking at a previous OPLEV spectra that was made in February on ETMX ITMX and ITMY (calibrated in urad/sqrtHz), it looks like the signal amplitude @ 10Hz (on the three of them) was similar to what you have on your red curve (~0.1 nrad/sqrtHz). Maybe the green trace (reference) was taken with a digital compensation filter engaged, but no analog whitenning ?

thomas.vo@LIGO.ORG - 13:48, Tuesday 25 March 2014 (10988)
Refer to ALOG-10267 for the changes in whitening settings on Feb 21st 2014. This accounts for the two orders of magnitude difference you see above 10 Hz.
H1 SEI
filiberto.clara@LIGO.ORG - posted 12:57, Monday 03 February 2014 - last comment - 14:24, Thursday 20 March 2014(9758)
Installation of Trillium T240 Seismometer - Ex
Installed Trillium Interface Chassis S1101837 in Rack SEI-C1 (slot U18).
Trillium was placed close to southwest side of BSC9.
Outputs from Trillium were connected to AA Chassis U30, CH21-26 (Port 5).
Trillium may need to be zero-ed.

Filiberto Clara
Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:24, Thursday 20 March 2014 (10899)
The serial number of this T240 is 000531.

Also, for information about calibration and cabling layout, checkout LHO aLOG 10635.
Displaying reports 77581-77600 of 88171.Go to page Start 3876 3877 3878 3879 3880 3881 3882 3883 3884 End