Reports until 16:09, Friday 03 June 2011
H2 INS
greg.grabeel@LIGO.ORG - posted 16:09, Friday 03 June 2011 (879)
HAM 7 HEPI Install

The crossbeam has been mounted in place between the South end HEPI assemblies. Unfortunately the layout of the weldment and the frame is preventing some of the bolts from being torqued down. The bottle jacks and the work table will remain in place until some way of torquing the bolts down can be figured out. Once this problem is solved things should move fairly quickly for finishing out the HAM. 

Images attached to this report
LHO FMCS
john.worden@LIGO.ORG - posted 16:26, Thursday 02 June 2011 (878)
LVEA Gate valve GV7
Opened GV7 as it was soft closed earlier in the day for craning operations.
LHO FMCS
john.worden@LIGO.ORG - posted 16:00, Thursday 02 June 2011 (877)
End Station Spool Delivery
This is the second shipment from GNB.

More photos here in the public collection "lho end station spool delivery" - https://ligoimages.mit.edu/?r=6580
Images attached to this report
H2 INS
patrick.thomas@LIGO.ORG - posted 15:55, Thursday 02 June 2011 (876)
Ops Shift Summary
installation of mechanical test stand supports in LVEA West Bay
LVEA transitioned to laser safe for box cleaning test and welding of HEPI tubing from mezzanine to BSC8
running turbo pump on X mid and Y mid
cleaning of top of vacuum tube in LVEA
work on supplying electrical service to new H2 electronics building
installation of air pressure gauge between plenum and LVEA
X1 SUS
robert.lane@LIGO.ORG - posted 12:50, Thursday 02 June 2011 (874)
Further Quad 2 ECD Block Testing
I conducted the relevant section of the ECD block testing again.
Non-image files attached to this report
LHO FMCS
kyle.ryan@LIGO.ORG - posted 11:44, Thursday 02 June 2011 (873)
Mid station pumping
Began pumping Y-mid on MTP.  X-mid BSC dome bolts not torqued -> will ask Apollo to torque dome bolts at X-mid
H2 INS
patrick.thomas@LIGO.ORG - posted 20:06, Wednesday 01 June 2011 (872)
elevated dust in LVEA including ISCT4
Dani, Filiberto, Grant, Keita, Patrick

The particle counts in the LVEA were unusually high today, including at ISCT4, where they should be zero. We went out to investigate ISCT4 and found that the HEPA filters were not running due to an undetermined electrical fault at the outlet. The power strip has been connected to another socket for the time being, and the counts have returned to zero. The .5 micron counts in ISCT4 are recorded in channel H0:PEM-LVEA_DST1_5 on the attached plot.
Non-image files attached to this report
H2 INS
patrick.thomas@LIGO.ORG - posted 19:15, Wednesday 01 June 2011 (871)
Operator Shift Summary
BSC6 moved from mid Y to end Y
Drilling holes for mechanical test stand installation in West bay
HEPI installation work
Delivery of laser partition wall
Delivery of vacuum parts
Fire alarm panel in computer users room has a fault
H2 INS
greg.grabeel@LIGO.ORG - posted 17:08, Wednesday 01 June 2011 (870)
HAM 7 HEPI Install

HAM 7 has the HEPI frames as well as the weldments in place and ready for the crossbeam.  The jacks holding up the support tubes had to be relocated to give clearance to the clamps as well as allowing an extension piece to be attached to the end of the support tube.  To do this two jacks and the top clamp were used to cradle the support tube while the extension was attached and the jack relocated.  The crossbeam is rigged with a spreader bar and should be ready to install shortly. 

Images attached to this report
LHO FMCS
john.worden@LIGO.ORG - posted 12:45, Wednesday 01 June 2011 - last comment - 15:13, Thursday 02 June 2011(869)
BSC chamber Move - Y arm
After lunch the chamber will move into the end station. No excitement at any time - this is good.
Images attached to this report
Comments related to this report
fred.raab@LIGO.ORG - 15:13, Thursday 02 June 2011 (875)
The doors to the EY Cleaning Room (a.k.a. air lock) were closed at 3:15pm 1-Jum-11, with the BSC inside (https://ligoimages.mit.edu/?r=6562).
H2 General
david.barker@LIGO.ORG - posted 10:16, Wednesday 01 June 2011 (868)
H1 DAQ ADCU EX, added Infrasound microphone channel
H1 DAQ H1ADCU_EX was reconfigured. We have replaced H1:SEI-ETMX_FINE2 with the new low frequency InfraSound Microphone channel H0:PEM-EX_IS_MIC. Acquisition rate remains at 256Hz.

X1 SUS
robert.lane@LIGO.ORG - posted 09:00, Wednesday 01 June 2011 (867)
QUAD 2 ECD Position Testing
Yesterday we completed some preliminary TF testing and ECD Damping tests on QUAD 2 (BSC 8 ITM). Attached plots include a comparison of: the previous build (Jan 2011), the Quad Model, no ECD blocks, ECD blocks reversed for minimal influence, and ECD blocks positioned approximately half-way over magnets. The plots are unscaled and have a couple of the model DOF mixed up. Note: The Watch Dog tripped during Pitch high frequency testing (without ECD blocks) preventing any drive signal being sent during the Yaw TF (without the ECD blocks). Yaw without ECD blocks is an un-driven response only. Once again, this is part of the preliminary testing and so this is not a concern because these tests were part of the process for building the new scripts, which will require several iterations before we are ready for final metal build testing.
Images attached to this report
X1 SEI
corey.gray@LIGO.ORG - posted 06:51, Wednesday 01 June 2011 (866)
BSC ISI Assembly Status

(Corey, Eric, Jeff, Jim)

BSCISI #2

LHO FMCS
dani.atkinson@LIGO.ORG - posted 16:38, Tuesday 31 May 2011 (865)
Ops Day Shift Summary
  • Jodi and Co. worked further cleaning box tests.
  • LVEA went to laser hazard this morning, there to remain for some months, with occasional interludes.
  • Dave reset the DAQ a few times and finally removed h1awg entirely. The DAQ resets have caused false alarms in the cryopumps, but should resolve themselves later tonight.
  • Keita and Co. are still attempting to recover the mode cleaner.
H2 General
david.barker@LIGO.ORG - posted 13:32, Tuesday 31 May 2011 (864)
iligo wiki machine swapped out
The old iligo wiki machine continues to freeze roughly once a week. So I swapped out the computer with the spare X2100 machine.
H2 General
david.barker@LIGO.ORG - posted 13:31, Tuesday 31 May 2011 (863)
vacuum epics rebooted
I rebooted the vacuum epics systems for EY, MY and MX to add the water pressure records. The EX channel was added at an earlier time. All four chans were added to the DAQ.
LHO FMCS
kyle.ryan@LIGO.ORG - posted 18:43, Friday 27 May 2011 (862)
Y-mid, Vertex, HAM6 pumping

Kyle-
Rough-pumped Y-mid to ~2 torr to add layer of vacuum safety-> No gauges mounted,i.e.no CDS pressure indication -> waiting for Class A flange to mount gauge pair and Class A blanks to replace unneeded viewports.  

Kyle-
Installed remaining door bolts on HAM6 east door and torqued.  Noticed gaps between flanges on HAM3, HAM2 and HAM1 east doors. Also, HAM1 west door.  Bolts too loose for those which are difficult to access.  Easy-access bolts were tight -> I torqued gaps closed on these doors.  

Pumping Vertex with Turbo over long weekend.  Also pumping HAM6 with turbo backed by portable pump cart over long weekend.
X1 SEI
corey.gray@LIGO.ORG - posted 15:52, Friday 27 May 2011 (861)
BSC ISI Assembly Status

(Corey, Eric, Greg, Hugh, Jeff G., Jim, Mitch)

BSC ISI #1

Only subassembly work today.  Today the Flexures were assembled. 

Also lots of organizing of parts.

BSC ISI #2

Spent most of the day flipping the Big Oven with Big Plates for the Assembly.

H2 General
jonathan.berliner@LIGO.ORG - posted 15:07, Friday 27 May 2011 (860)
Friday Ops Log
- No laser hazard today.
- Hugh and Apollo transport items between outbuildings.
- Terry Santini makes rounds at outbuildings.
- Gerardo and Keita take photos at REFL port and ISCT4.
- Dell support arrives for JonathanH.
- JonathanB measures viewport height at EY.
- Big group for Friday public tour.
- Ongoing preparations for welding in LVEA.