Displaying reports 80261-80280 of 88158.Go to page Start 4010 4011 4012 4013 4014 4015 4016 4017 4018 End
Reports until 17:49, Thursday 17 October 2013
H1 SUS
arnaud.pele@LIGO.ORG - posted 17:49, Thursday 17 October 2013 (8154)
ETMX Results

[Mark Arnaud]

Results of ETMX M0 and R0 phase 3a (in chamber, in air) transfer functions from yesterday night have been processed and are plotted in the attached documents.

(1) Comparison between undamped M0 TF and model

(2) Comparison between undamped R0 TF and model

(3) Comparison between undamped M0 TF LHO phase 3a (in chamber), phase 2c, and LLO phase 2c

 

Main chain of ETMX is matching well the model cf (1), meaning it was freely suspended during the alignment (cf 8126). Only two modes of pitch are shifted down, which is a feature we already saw previously (cf (2) and alog 7415)

R0 measurements are not matching the model as well as M0, meaning something might be rubbing. Transverse and yaw degrees of freedom are very noisy. It makes sense for yaw, since the watchdog tripped when it was beeing driven, although it is not clear yet for transverse cf (2). It could be an issue in the actuation chain and I will take a closer look tomorrow.

Non-image files attached to this report
H1 SEI
stefan.ballmer@LIGO.ORG - posted 17:12, Thursday 17 October 2013 - last comment - 06:55, Friday 18 October 2013(8156)
ISI medm macro files not consistent
In the process of adding subsystem links to the ODC channels I came across some inconsistencies in the medm macro files:

ISI:
there exist currently

/opt/rtcds/userapps/release/isi/common/medm/isibs_overview_macro.txt
/opt/rtcds/userapps/release/isi/common/medm/isietmx_overview_macro.txt
/opt/rtcds/userapps/release/isi/common/medm/isietmy_overview_macro.txt
/opt/rtcds/userapps/release/isi/common/medm/isiham2_overview_macro.txt
/opt/rtcds/userapps/release/isi/common/medm/isiham3_overview_macro.txt
/opt/rtcds/userapps/release/isi/common/medm/isiham4_overview_macro.txt
/opt/rtcds/userapps/release/isi/common/medm/isiham5_overview_macro.txt
/opt/rtcds/userapps/release/isi/common/medm/isiham6_overview_macro.txt
/opt/rtcds/userapps/release/isi/common/medm/isiitmx_overview_macro.txt
/opt/rtcds/userapps/release/isi/common/medm/isiitmy_overview_macro.txt

and

/opt/rtcds/userapps/release/isi/h1/medm/bscisi/isibs_overview_macro.txt
/opt/rtcds/userapps/release/isi/h1/medm/bscisi/isietmx_overview_macro.txt
/opt/rtcds/userapps/release/isi/h1/medm/bscisi/isiitmx_overview_macro.txt
/opt/rtcds/userapps/release/isi/h1/medm/bscisi/isiitmy_overview_macro.txt
/opt/rtcds/userapps/release/isi/h1/medm/bscisi/isitst_overview_macro.txt
/opt/rtcds/userapps/release/isi/h1/medm/hamisi/isiham2_overview_macro.txt
/opt/rtcds/userapps/release/isi/h1/medm/hamisi/isiham3_overview_macro.txt
/opt/rtcds/userapps/release/isi/h1/medm/hamisi/isiham4_overview_macro.txt
/opt/rtcds/userapps/release/isi/h1/medm/hamisi/isiham5_overview_macro.txt
/opt/rtcds/userapps/release/isi/h1/medm/hamisi/isiham6_overview_macro.txt
/opt/rtcds/userapps/release/isi/h1/medm/hepi/hepiham1_overview_macro.txt

and

/opt/rtcds/userapps/release/isi/l1/medm/bscisi/L1_isibs_overview_macro.txt
/opt/rtcds/userapps/release/isi/l1/medm/bscisi/L1_isietmx_overview_macro.txt
/opt/rtcds/userapps/release/isi/l1/medm/bscisi/L1_isietmy_overview_macro.txt
/opt/rtcds/userapps/release/isi/l1/medm/bscisi/L1_isiitmx_overview_macro.txt
/opt/rtcds/userapps/release/isi/l1/medm/bscisi/L1_isiitmy_overview_macro.txt
/opt/rtcds/userapps/release/isi/l1/medm/hamisi/L1_isiham2_overview_macro.txt
/opt/rtcds/userapps/release/isi/l1/medm/hamisi/L1_isiham3_overview_macro.txt
/opt/rtcds/userapps/release/isi/l1/medm/hamisi/L1_isiham4_overview_macro.txt
/opt/rtcds/userapps/release/isi/l1/medm/hamisi/L1_isiham5_overview_macro.txt
/opt/rtcds/userapps/release/isi/l1/medm/hamisi/L1_isiham6_overview_macro.txt


more that
1) h1 and l1 files are named differently and
2) some common files exist

SEI needs to sort out which ones we need to use



Also, for HPI, there exist:
/opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepibs_overview_macro.txt
/opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiham1_overview_macro.txt
/opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiham2_overview_macro.txt
/opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiham3_overview_macro.txt
/opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiham4_overview_macro.txt
/opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiham5_overview_macro.txt
/opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiham6_overview_macro.txt
/opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiitmy_overview_macro.txt

and

/opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpibs_overview_macro.txt
/opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpietmx_overview_macro.txt
/opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpietmy_overview_macro.txt
/opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiham1_overview_macro.txt
/opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiham2_overview_macro.txt
/opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiham3_overview_macro.txt
/opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiham4_overview_macro.txt
/opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiham5_overview_macro.txt
/opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiham6_overview_macro.txt
/opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiitmx_overview_macro.txt
/opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiitmy_overview_macro.txt


Note that
1) they have different name structures at the different sites
2) not all files exist for hanford
3) they are in different sub-directories




========================


I plead for standardization and sanity!
Comments related to this report
celine.ramet@LIGO.ORG - 06:55, Friday 18 October 2013 (8157)

As far as I know, the reason why we have site specific safe.snap is due to Livingston inconsistency with the design wiring diagram. It is on the to-do list.

H1 SUS
betsy.weaver@LIGO.ORG - posted 16:23, Thursday 17 October 2013 (8153)
BSC3 installation contamination control

Today, during our contamination control discussions, Gerardo discovered that the X-beam tube manifold purge valve was still closed.  He opened it and the BSC3 soft cover showed sights of life billowing outward a bit.  So, it seems that since the vent ~10 days ago, we have only had the MC purge enabled which was not enough to supply positive pressure to all of the vented volume.  Darn.

To improve hampered HEPA flow at the BSC3 entrance (the walking plates almost completely occult the line-of-sight to the cleanroom ceiling HEPAs), I have set the draw fan previously used in chamber cleaning near the front of the chamber door through the soft wall curtains.  I have not turned it on because I am waiting for a particle counter to magically appear near the door to monitor the dust level (ehem, also ~10 days late).

Images attached to this report
H1 SEI
richard.mittleman@LIGO.ORG - posted 16:10, Thursday 17 October 2013 - last comment - 14:38, Monday 21 October 2013(8152)
ITMY HEPI

ITMY now has two HEPI controllers installed (both of which work I think)

 

Control Level one is a positon sensor only ~5Hz UUG  in all DOF (VP and HP are AC coupled at some low frequency (<1mhz))

Control Level two, uses the second set of blend filters (lil bit iso) just the second button and has ~10Hz UUG (5Hz for VP and HP)

  It blends X,Y Z and rZ at about  0.5Hz  and rX and rY at about 0.8Hz

 

  I tried to design with minimum gain peaking every where (< a factor of two if you believe  linear control theory, which HEPI doesn't always)

  I characterized this controller in /ligo/svncommon/Seisvn/seismic/HEPI/H1/ITMY/Data/Spectra/Preformance_A.xml

 

There are three screen shots from this dtt attached, the Ref plots are with HEPI controls ON

 

The orange like color  and green are the ISI stage 1 T240 modal signals HEPI on/off

The pinkish  or grey and blue are the HEPI L4C signals on/off

red and pinkish are sts2 ground signals during the two tests

 

I don't really believe all of that isolation in the rotational directions, not sure why it is there .....

 

 

  **** the HEPI on script doesn't seem to be working so well hopefully this will get fixed soon ****

Images attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 14:38, Monday 21 October 2013 (8199)

Here are the plots Rich meant to attach :

Images attached to this comment
LHO General
patrick.thomas@LIGO.ORG - posted 16:07, Thursday 17 October 2013 (8138)
Ops Summary
~ 09:00 - 11:00 Thomas and Gerardo working on baffle installation in BSC3
Dave restarted the models and IOP on H1SUSH34
Roofing and insulation removal continuing
H1 AOS
thomas.vo@LIGO.ORG - posted 15:39, Thursday 17 October 2013 - last comment - 21:27, Friday 18 October 2013(8151)
ITMX ACB in BSC3
Mitchell, Gerardo, Apollo (Scott, Randy, Tyler), Thomas

We got the suspension and the box into chamber and mounted onto stage-0.  The next steps are:

- Photodiode cabling
- Fine-tune alignment
- Check balance
- Set the eddy current dampening gap
- Wipe down
- Swing Back for first contact removal
Comments related to this report
thomas.vo@LIGO.ORG - 21:27, Friday 18 October 2013 (8180)
Filiberto C, Thomas V

We wanted to make sure that at least 3/4 of the photodiodes that were installed on the ITMX baffle worked since there were failures of all the other spares (under investigation). So after replacing a faulty cable, we found that all three have continuity and registered a signal when shined upon with a flashlight.  The PDs that work are PD1, PD2, and PD4, a mapping of their locations on the baffle can be found in E1100867 pg 21.
H1 AOS
jason.oberling@LIGO.ORG - posted 15:31, Thursday 17 October 2013 - last comment - 08:07, Friday 18 October 2013(8150)
WBSC9 ETMx Alignment
IAS: J. Oberling
SEI: J. Warner, G. Grabeel
 
We aligned the Y and Z (lateral and vertical, repsectively) positions and Yaw of the ETMx this morning via HEPI adjustments (position coordinates are local to End X):
Comments related to this report
greg.grabeel@LIGO.ORG - 17:05, Thursday 17 October 2013 (8155)

The final dial indicator values for those values.

  1 2 3 4
X 0.532 -- -- 0.623
Y 0.203 0.329 0.636 0.542
Z 0.419 0.430 0.406 0.474

(Corner 4 X value is so different because I was reading the dial indicator differently, it didn't actually change that much.)

jim.warner@LIGO.ORG - 08:07, Friday 18 October 2013 (8158)

Greg and I also did a quick measurement of the level after alignment. I didn't try to calculate a height, but the table is level to within .010" over the span of the optical table, with 3 of 4 corners being more like .005" difference. This agrees with the spec used for the test stands, so I assume this is good enough.

H1 ISC
sheila.dwyer@LIGO.ORG - posted 15:11, Thursday 17 October 2013 (8145)
2 inch HR for HAM6 cleaned

Keita, Kiwamu, Sheila

 

We cleaned the last of the optics needed for HAM6, a 2 inch HR for 1064 with SN 0984.  There are some small marks that look like scratches on the AR side, a photo is attached.  Keita doesn't think this is a serious problem.  

Images attached to this report
LHO VE
john.worden@LIGO.ORG - posted 14:33, Thursday 17 October 2013 (8149)
Beam Tube Insulation Removal

Insulation removal started in earnest on Tuesday of this week. The vendor is using a soft sided 54 foot trailer to load waste insulation into. Once a day they fill the trailer and take it to the city dump where they have stationed another forklift to help push the insulation off of the trailer.

They are making very good progress - starting at the LVEA they have progressed to the third double door which is ~2400 feet down the arm or ~800 feet per day.

Photos show the work in progress and the end result - a clean beam tube enclosure.

Images attached to this report
LHO General
john.worden@LIGO.ORG - posted 14:23, Thursday 17 October 2013 (8147)
Roofing Progress

A few pictures of the recent state of our roofing project. The first two photos show the XEND station roof from the backside. The metal trim is in process. This is the first of the trim work.

The other 3 pictures show today's state of the LVEA roof. I expect the membrane on this level to be complete early next week.

Images attached to this report
LHO VE
patrick.thomas@LIGO.ORG - posted 14:23, Thursday 17 October 2013 (8148)
Set the HIHI alarm level values and severities for the beam tube pressures
I ran the following:

caput HVE-EY:Y1_423BTORR.HIHI 4.77e-08
caput HVE-MY:Y5_246BTORR.HIHI 5.11e-08
caput HVE-MY:Y1_243BTORR.HIHI 3.81e-08
caput HVE-LY:Y4_124BTORR.HIHI 8.47e-08
caput HVE-EX:X1_523BTORR.HIHI 4.08e-08
caput HVE-MX:X5_346BTORR.HIHI 1.48e-08
caput HVE-MX:X1_343BTORR.HIHI 2.12e-08
caput HVE-LX:X4_144BTORR.HIHI 2.69e-08
caput HVE-EY:Y1_423BTORR.HHSV MAJOR
caput HVE-MY:Y5_246BTORR.HHSV MAJOR
caput HVE-MY:Y1_243BTORR.HHSV MAJOR
caput HVE-LY:Y4_124BTORR.HHSV MAJOR
caput HVE-EX:X1_523BTORR.HHSV MAJOR
caput HVE-MX:X5_346BTORR.HHSV MAJOR
caput HVE-MX:X1_343BTORR.HHSV MAJOR
caput HVE-LX:X4_144BTORR.HHSV MAJOR
H1 AOS
douglas.cook@LIGO.ORG - posted 14:18, Thursday 17 October 2013 (8146)
BSC3 ACB rough position first look
I looked at the ITMx ACB position for any gross positional errors with respect to the ITMx. Athough the ISI and ITM are on stops the indication from the total station is the ACB will not interfere with the fine alignment of the ITMx. The ITMx rough position looking from the spool is good as far as the optic cap centering goes. I predict that we will need little elevation or lateral adjustment.
We won't know about longitudinal position or pitch and yaw until the ISI and SUS are leveled, TFs are done and the optic is suspended.
LHO VE
patrick.thomas@LIGO.ORG - posted 14:00, Thursday 17 October 2013 (8144)
Accidently set the value of the beam tube pressure
I intended to change the channel's alarm level, but accidentally set the value of the channel itself.

HVE-EY:Y1_423BTORR got briefly changed from 4.77394e-09 to 4.77e-08.

A plot of the change is attached.
Non-image files attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 10:53, Thursday 17 October 2013 (8141)
h1sush34 problems, needed restart

h1sush34 developed a timing error at 09:45 PDT. I activated the IOP DACKILL and restarted all the models (MC2, PR2, SR2 and IOP), which cleared the problem. The IOP Watchdogs in turn tripped h1seih23 (h1seih45 was already tripped). 

The cause of the timing error is currently unknown. I'm leaving all systems tripped.

X1 SUS
james.batch@LIGO.ORG - posted 10:37, Thursday 17 October 2013 (8139)
(From Yesterday) Started nds process, restarted daqd on tripleteststand
From late Wednesday afternoon - After issues were encountered running a Matlab script I looked at the tripleteststand.  Checked the system time and the model time, found them to be as close as can be expected.  Noted that the NDS process was not running, and couldn't be kept running when started.  Killed the daqd process, started the nds process, then restarted the daqd process.  

Checked the ability to get data from _DQ and testpoint channels using dataviewer, all appeared OK.  Jeff Bartlett confirmed that the Matlab script could be run successfully this morning.
H1 SUS
arnaud.pele@LIGO.ORG - posted 00:58, Thursday 17 October 2013 - last comment - 11:53, Thursday 17 October 2013(8132)
ETMX transfer functions

Started M0 and R0 undamped ETMX transfer functions

Comments related to this report
mark.barton@LIGO.ORG - 09:10, Thursday 17 October 2013 (8135)

Checked at 9:00 am: still running, had reached R0 R.

mark.barton@LIGO.ORG - 11:53, Thursday 17 October 2013 (8142)

TFs had finished when checked at 11:30 am. The very last band of the very last DOF of R0 was interrupted by a watchdog trip, presumably from ISI work, but the rest of the data should be usable. 

I reset the watchdogs, enabled the damping and turned off the measurement status indicator.

Plots pending.

H1 SUS
betsy.weaver@LIGO.ORG - posted 15:51, Tuesday 08 October 2013 - last comment - 10:52, Thursday 17 October 2013(8054)
ETMx SUS cables connected

Betsy, Travis

This afternoon, we connected the 5 ETMx SUS cables and the ringheater cable to the inside of the feedthru flange.  We then had issues with signal faults.  We investigated and found the out-of vac cables not plugged in well at the outside of the feedthru.  Apon fixing, all looked well with the signals.  The suspension is still not fully suspended although we pulled out all of the extra teflon stopping brackets and prepped it for full unlock after SEI is done float/balance, after IAS is done figuring out where to put us.

Comments related to this report
jim.warner@LIGO.ORG - 10:52, Thursday 17 October 2013 (8140)

Note - Yesterday (Oct 16) we discovered that we had incorrectly pugged the cables into the internal side of the feedthru.  This was due to the fact that the cable connectors were mounted in the table bracket slightly incorrectly.  We remedied this yesterday.

H1 IOO
sheila.dwyer@LIGO.ORG - posted 11:48, Monday 07 October 2013 - last comment - 12:36, Thursday 17 October 2013(8012)
IMC transmitted beam on IOT2L

I used thenano scan to measure a beam profile on IOT2L.  near the periscope, the vertical waist diameter is 4411um.  The horizontal beam isnot gaussian, the waist diameter fit is 4007um.  (screen shot is first image attached to this report) This was taken 3 and 1/2" from the bottom periscope mirror, the periscope height is 23 and 1/2 ", and the top periscope mirror is approx 2'8 and1/2" from the viewport.  This data is saved as IOT2L1 on the nanoscan computer.  

I moved the scan head back to  14"  behind the botttom periscope mirror, and measured 4405 um diameter vertical , the horizontal beam still is non gaussian, but the diameter is 4070 um.  (screen shot is second image attached)

This data is now transfered to http://www.ligo-wa.caltech.edu/~sheila.dwyer/NanoScanData/IO/

Images attached to this report
Comments related to this report
rodica.martin@LIGO.ORG - 12:36, Thursday 17 October 2013 (8143)

According to these alogs - 6403 and 6265 - the IMC Trans beam might be clipping at the HAM2 viewport. 

Displaying reports 80261-80280 of 88158.Go to page Start 4010 4011 4012 4013 4014 4015 4016 4017 4018 End