kiwamu.izumi@LIGO.ORG - posted 01:06, Wednesday 03 July 2013 (6973)
HIFOY : characterization of the ALS CARM control and etc

[Daniel, Stefan, Kiwamu]

 For some reason we frequently failed handing the MC control off to the ALS CARM signal this time around. We checked several things to make sure we are back to the configuration we were in the past Friday. Also we aligned the in-vac picomotors to center the infrared beams on their trans QPDs on TMSY.

Also we took a new noise spectrum without the RGA pump running nearby HAM3, the noise spectrum didn't show a big improvement at around 60-70 Hz in which we thought it would improve.

 

Besides we did the following things :

H1 ISC
daniel.sigg@LIGO.ORG - posted 20:54, Tuesday 02 July 2013 (6972)
VCO Stability
(Dick G, Daniel S)

We added a second frequency difference divider to the rack. For now we just used the output of the DIFF VCO as its input. The division ratio is 10. The attached plot shows the stability of its output as measured by the timing frequency counter. The standard deviation of the distribution is around 2.0 Hz. This is about an order of magnitude better than the single stage measured here. Of course the range has been reduced accordingly and is now roughly +/-100 kHz.
Non-image files attached to this report
H1 SUS
arnaud.pele@LIGO.ORG - posted 19:55, Tuesday 02 July 2013 (6971)
ETMY open loop transfer functions

M0 to M0 transfer function measurement in longitudinal (open loop with a gain of 3) on ETMY will start from 2:00 am

H1 SUS
jeffrey.kissel@LIGO.ORG - posted 19:47, Tuesday 02 July 2013 (6970)
Assessment of L/P Gain = 1 vs. 3
J. Kissel

Now that (we think) we trust our model to predict the open loop gain transfer function at all frequencies in the current H1 SUS ETMY damping loop configuration with an EPICs gain of 1.0 (see LHO aLOG 6969), I've made a model of how increasing the gain in L and P by 3.0 compares to a gain of 1.0. The gain of 3.0 configuration is what the ISC commissioners run to reduce the spot motion to what they desire (on a camera alone), and some how it is stable. (And yes, they still run with the ISIs only damped, because there is too much low-frequency motion generated by the isolation loops -- also a camera alone "measured" statement).

The first attachment are the loop figures of merit. Dashed lines are for a gain of 1.0, and solid lines are a gain of 3.0. We see that the Longitudinal loop should have a upper unity gain phase margin at 3.9 [Hz] of 9 [deg]. This causes a factor of 10 gain peaking at 4 [Hz]. In addition, the (originally) 0.43 [Hz] mode is no longer damped, but distorted to 0.35 [Hz]. In Pitch, although the loop is not as unstable as L, there is still a sharp gain peaking feature at 5.1 [Hz] because the gain margin is so small. Similarly, the lowest (originally) 0.56 [Hz] mode is distorted down to 0.43 [Hz].

We have yet to measure the open loop gain of this exact L/P Gain = 3 configuration, but we were able to get some passive measurements:
(1) A comparison of the in loop OSEM sensors, which show similar distortion, and 
(2) Optical lever spectra of the G = 3 configuration alone to quantify what a "good" level of motion for the cavity locking is. 
These are the second and third attachments. Confusingly, the L in-loop sensors seem to follow the model behavior, but we don't see similar modification on the middle frequency resonances in Pitch. Also, the optical lever spectra show none of the expected gain peaking.

Non-image files attached to this report
H1 SUS
daniel.sigg@LIGO.ORG - posted 19:05, Tuesday 02 July 2013 (6969)
H1 SUS ETMY High Resolution Longitudinal OLGTF Measurement vs. Model
J. Kissel, A. Pele

Given that we were suspicious of the one data point that appeared to show model inaccuracies at the most troublesome 0.43 [Hz] mode of H1 SUS ETMY (see LHO aLOG 6933), we took the time to gather a really high (0.001 [Hz]) resolution, open loop gain transfer function. Comparing this against the model reveals the model matches with measurement very very well. No such double peak is visible. 

The only remaining discrepancies are the "known" differences -- a little bit off in frequency for the 0.56 [Hz] first pitch mode, and the ~30 [Hz] zero that's from cross coupling of drive to sensor signal in the readout chain (i.e. not representative of the suspended dynamics).

For posterity, this was measured with the 2013-05-01 filters, with the extra 0.43 and 1 [Hz] boosts installed by Arnaud, and the overall EPICs gain was set to 1.0. We again see that the phase margin is only 19 [deg]. More to come on installation of a better loop design (i.e. installing the one we already have one in our pocket; see LHO aLOG 6760).

Non-image files attached to this report
H1 General
stefan.ballmer@LIGO.ORG - posted 18:04, Tuesday 02 July 2013 (6968)
Ey boot fest
We found ETMY moving about a factor of 10 more (mostly pitch), as seen by the OPLEVs, as well as with beam spot motion. In addition the DAC noise level was increases. Similarly the IST GS13s showed at least two sick channels (higher DAC noise, ratty, 10x higher signal at lower frequencies.) After chasing our tail for about 4h, Dave suggested a remote power cycles.

Thus Jim remote power cycled all EY front ends, and we restored them to Friday's burt settings. That fixed the sick channels, and the arm locked right up with no extra motion.
LHO General
patrick.thomas@LIGO.ORG - posted 17:51, Tuesday 02 July 2013 (6965)
Ops Summary
8:46 Pablo D. and Colin S. went into the H2 PSL enclosure to work on PCAL.
9:05 Michael R. went into the H2 PSL enclosure to work on PCAL.
9:27 A truck arrived to pickup pallets.
Hugh R. restarted the end Y HEPI pump controller. (WP 4012)
Corey G. went to end Y and the end X TMS lab.
h1fw1 was taken down to attach a new SSD raid. (see entry 6963) (WP 4011)
10:51 Dick G. went into the LVEA to look at the racks by the H1 PSL and ISCT1 table.
11:12 Thomas V. went into the LVEA to take an inventory of baffles.
11:25 Jim B. went into the LVEA to restart the test stand frontend computers.
Dave B. rebooted the OAF and LSC frontend computers to try to fix IPC errors.
Dale I. brought a school tour through the control room.
Dave B. rebooted the ASC frontend computer to try to fix IPC errors. This unexpectedly created errors on most of the other frontends.
12:34 Dave B. powercycled the RFM switch at end Y to try to fix IPC errors.
1:05 Pablo D. and Colin S. went into the H2 PSL enclosure to work on PCAL.
2:32 Pablo D., Colin S. and Michael R. finished work for the day in the H2 PSL enclosure.
3:40 The commissioners rebooted seiey.
4:58 Jim B. powercycled all the frontend computers at end Y. (see entry 6966)

Jeff B. and Andres R. moved the TMS-X upper structure to end X and installed it on the Bosch frame platform. (WP 4013)
Richard M. worked on the computer for the access card reader.
H1 CDS
james.batch@LIGO.ORG - posted 17:25, Tuesday 02 July 2013 (6967)
MSR overheating, doors opened.
An air conditioning unit failed in the MSR, and temperatures were a bit on the warm side so the doors to the MSR have been opened and a fan to circulate air has been started.  This is a precaution in case of failure of a second air conditioner which would cause the temperature to rise rapidly.
H1 CDS
james.batch@LIGO.ORG - posted 17:21, Tuesday 02 July 2013 (6966)
Restart EY front-end computers, restart DAQ
Power down h1susauxey, h1iscey, h1seiey, and h1susey, then power up computers to see if unexpected noise on ADC channels goes away.

Restarted DAQ at 17:17 PDT for channel changes. 
H1 CDS
james.batch@LIGO.ORG - posted 15:57, Tuesday 02 July 2013 (6964)
Added gvim to control room workstations
Added the vim-gtk package to opsws0-opsws7 (omitting opsws6) to provide "gvim" at the request of one of our scientists.  gvim is a nice implementation of vim which works nicely with an X11 connection.  So if you "ssh -X name@workstation", you can use gvim.
H1 DAQ
james.batch@LIGO.ORG - posted 15:13, Tuesday 02 July 2013 (6963)
Reconfigure h1fw1 raw minute data
Cyrus, Dave, Jim

WP #4011

Attached a new SSD RAID to h1fw1.  This RAID is to be used for storage of raw minute data that was formerly written to the SATAboy hard drive array.  Reconfigured the h1fw1 daqd to write raw minute data to /trend/minute_raw instead of /frames/trend/minute_raw.  Reconfigured h1nds1 to read raw minute data from both /frames/trend/minute_raw and /trend/minute_raw.  The raw minute data in /frames/trend/minute_raw is now in two subdirectories of /frames/trend/minute_raw, and is considered archive data while still being available for viewing via h1nds1.

Note that frame files written to /frames/full, /frames/trend/minute, and /frames/trend/second are not affected by this change.
H1 SUS
mark.barton@LIGO.ORG - posted 15:06, Tuesday 02 July 2013 (6962)
New quad metal-build models

I created Mathematica versions of the quadopt_wire.m and quadopt_wireloop.m quad parameter sets for the quad main chain metal builds.

20121115TMproductionWire is the old-style metal build of the quad main chain. It corresponds to ^/trunk/QUAD/Common/MatlabTools/QuadModel_Production/quadopt_wire.m r3736 of 11/15/12. The Mathematica version is in the SUS SVN at ^/trunk/Common/MathematicaModels/QuadLite2Lateral/20121115TMproductionWire and the wiki at https://awiki.ligo-wa.caltech.edu/aLIGO/Suspensions/OpsManual/QUAD/Models/20121115TMproductionWire

20130523TMproductionWireLoop is the new-style metal build of the quad main chain with prisms on the PUM and the final wire loop under it. It corresponds to ^/trunk/QUAD/Common/MatlabTools/QuadModel_Production/quadopt_wireloop.m r4760 of 5/23/13. The Mathematica version is in the SUS SVN at ^/trunk/Common/MathematicaModels/QuadLite2Lateral/20130523TMproductionWireLoop and the wiki at https://awiki.ligo-wa.caltech.edu/aLIGO/Suspensions/OpsManual/QUAD/Models/20130523TMproductionWireLoop

H1 SEI
hugo.paris@LIGO.ORG - posted 11:40, Tuesday 02 July 2013 (6960)
HAM Status

Here is the current status of the aLIGO SEI work regarding the HAM chambers. Everything in bold is to be completed for HIFO-Y. Everything in red is a change from last week's status. Everything in green is available.

 

·         HAM 1

o    HEPI unlocked and running
      Ongoing low priority testing 
      One L4C needs to be replaced: H2
      One actuator is weak: V4 It is 20% weaker than its counterparts. Likely clogged. May require replacement further down the line.

·         HAM2

o   ISI: previously commissioned with HEPI locked (recent performance spectra), currently unlocked, in vacuum

o   HEPI: to be commissioned, currently locked, models and electronics ready. Commissioning could start once HEPI is unlocked.

·         HAM 3

o   ISI: previously commissioned with HEPI locked (recent performance spectra), currently unlocked, in vacuum

o   HEPI: To be commissioned, currently locked, model and electronics ready. Commissioning could start once HEPI is unlocked.

·         HAM 4 

o   ISI: In chamber, Previously tested during assembly validation, currently locked, no suspension installed, in-vac cables not connected, chamber temporarily closed.
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Simulink Model was created.
     Model is running, and MEDM screens are available in the Sitemap.

o   HEPI: Currently locked, to be commissioned
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Simulink Model was created.
     Model is running, and MEDM screens are available in the Sitemap.

·         HAM 5

o   ISI: In Chamber, Previously tested during assembly validation, currently locked, no suspension installed, in-vac cables not connected, chamber temporarily closed.         
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Simulink Model was created.
     Model is running, and MEDM screens are available in the Sitemap.

o   HEPI: Currently locked, to be commissioned     
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Simulink Model was created.
     Model is running, and MEDM screens are available in the Sitemap.

 

·         HAM 6

o   ISI: Chamber-Side
     Retrofitted with aLIGO censors (GS13, CPS) 
     Cables are being ran to the test stand (shipping container)
     temporary feed-through are being cleaned
     Chamber-side testing (Sensor check) starting soon

                            Electronics ready (Corner 2 CPS interface damaged by faulty cable, will be replaced today), in field cables ready, in-rack cables ready. Temporary STS cables

    Simulink Model was created.
    Model is running, and MEDM screens are available in the Sitemap.

 

o   HEPI: Currently locked, to be commissioned
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Simulink Model was created.
     Model is running, and MEDM screens are available in the Sitemap.

 
 
 
 
 
 
H1 CDS
james.batch@LIGO.ORG - posted 09:36, Tuesday 02 July 2013 (6958)
Default nds server has been changed to h1nds0
To allow installation of the SSD RAID on h1fw1, the default nds server setting for applications has been changed to h1nds0.  This only affects new shells and processes, so if a process that was connected to h1nds1 fails to collect data as we work on h1nds1, you'll have to wait or restart the process from a new shell.
H1 ISC
corey.gray@LIGO.ORG - posted 08:35, Tuesday 02 July 2013 (6956)
Yesterday's (Mon 7/1) TMS (Telescope/Table) Activities

In-Vac ISC Table

Telescope

Misc.

H1 SUS
arnaud.pele@LIGO.ORG - posted 00:03, Tuesday 02 July 2013 - last comment - 09:16, Tuesday 02 July 2013(6955)
ETMY open loop transfer functions

Starting transfer functions measurements on ETMY from 2:00 am

Comments related to this report
arnaud.pele@LIGO.ORG - 09:16, Tuesday 02 July 2013 (6957)

ETMY M0 watchdog were tripped when arrived this morning, and measurement was relaunched at 9:00 am.

H1 ISC
stefan.ballmer@LIGO.ORG - posted 23:27, Monday 01 July 2013 (6954)
EY work


			
			
H1 ISC
stefan.ballmer@LIGO.ORG - posted 23:27, Monday 01 July 2013 (6953)
EY work
(Sheila, Stefan)

- Finished the LSC transmon alignment - we put in an ND1 and left the PD in 0dB gain - that gives us about 1e4cts on fringe
- Set up high dynamic range camera and additional lense for the IR trans camera.
- Plugged in the EY pico motors and verified (after some cable debugging) that they move - they still need to be centered on the QPD A and B
- Tightened some screw.
H1 ISC
stefan.ballmer@LIGO.ORG - posted 19:51, Monday 01 July 2013 - last comment - 12:45, Tuesday 02 July 2013(6949)
5h VCO drift plot
Here are plots of the long term drift of the arm offset frequency (as measured my H1:ASC-Y_TR_A_NSUM_OUT), and the 3 relevant VCO frequencies. All curves are calibrated in Hz IR.

Between 1600sec and 2000sec we manually moved the ALS-C_COMM_VCO_FREQUENCY to the next fringe and back.
The alignment was tweaked up between 2600sec and 2800sec.

Traces, top:
 - Blue: IR transmitted light, calibrated in Hz using zpk([81.9545+i*81.9529;81.9545-i*81.9529],[850;850],0.656,"n")
 - Red: ALS-C_COMM_VCO
 - Bright green: Green light transmitted (arb. units)
Traces, bottom (note that the scale is 1000x bigger):
 - Green: ALS-Y_VCO
 - Gold: IMC-VCO

Conclusions
- For 3h the IR frequency offset was well predicted by the ALS-C_COMM_VCO - I don't what happened at about 11000sec.
- To epics channel precision the IMC-VCO cancels out ALS-Y_VCO exactly (actually, I'd expect the difference to be equal to ALS-C_COMM_VCO, but they are too noisy to tell)
- The alignment tweak at 1600sec to 2000sec changed the offset by about 50Hz.
- A typical RMS over 10min is about 12Hz, dominated by VCO motion.
Non-image files attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 12:45, Tuesday 02 July 2013 (6961)
I should have mentioned the calibration required to get IR Hz:
ALS-C_COMM_VCO: x0.5 (green light conversion)
ALS-Y_VCO:      x0.5 (green light conversion)
IMC-VCO:        x2.0 (double-pass)

All calibrations also include a large offset to get the numbers down to ~100Hz to be plot-able.